Reproducibility of Spectral-Domain Optical Coherence Tomography Retinal Thickness Measurements and Conversion to Equivalent Time-Domain Metrics in Diabetic Macular Edema

被引:81
作者
Bressler, Susan B. [1 ]
Edwards, Allison R. [2 ]
Chalam, Kakarla V. [3 ]
Bressler, Neil M. [1 ]
Glassman, Adam R. [2 ]
Jaffe, Glenn J. [4 ]
Melia, Michele [2 ]
Saggau, David D. [5 ]
Plous, Oren Z. [6 ]
机构
[1] Johns Hopkins Univ, Sch Med, Wilmer Eye Inst, Baltimore, MD 21205 USA
[2] Jaeb Ctr Hlth Res, Tampa, FL 33647 USA
[3] Univ Florida, Coll Med, Hlth Sci Ctr Jacksonville, Dept Ophthalmol, Jacksonville, FL USA
[4] Duke Univ, Dept Ophthalmol, Durham, NC USA
[5] Wolfe Eye Clin, Des Moines, IA USA
[6] Gulf Coast Retina Ctr, Port Richey, FL USA
基金
美国国家卫生研究院;
关键词
OCT; VOLUME;
D O I
10.1001/jamaophthalmol.2014.1698
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE Understanding measurement variability and relationships between measurements obtained on different optical coherence tomography (OCT) machines is critical for clinical trials and clinical settings. OBJECTIVE To evaluate the reproducibility of retinal thickness measurements from OCT images obtained by time-domain (TD) (Stratus; Carl Zeiss Meditec) and spectral-domain (SD) (Cirrus; Carl Zeiss Meditec, and Spectralis; Heidelberg Engineering) instruments and formulate equations to convert retinal thickness measurements from SD-OCT to equivalent values on TD-OCT. DESIGN SETTING, AND PARTICIPANT A cross-sectional observational study was conducted in private and institutional practices. Persons with diabetes mellitus who had at least 1 eye with central-involved diabetic macular edema, defined as Stratus central subfield thickness (CST) of 250 pm or greater, participated. An additional normative cohort (individuals with diabetes but without diabetic macular edema) was enrolled. Each study eye underwent 2 replicate Stratus scans followed by 2 replicate Cirrus or Spectralis scans (real-time image registration used) centered on the fovea. MAIN OUTCOMES AND MEASURES Optical coherence tomography CST and macular volume, RESULTS The Bland-Altman coefficient of repeatability for relative change in CST (the degree of change that could be expected from measurement variability) was lower with Spectralis (7%) compared with Cirrus (14%) and Stratus (12% and 15% within Cirrus/Stratus and Spectralis/Stratus groups, respectively). For each cohort, the initial Stratus CST was within 10% of the replicate Stratus measurement nearly all of the time; the conversion equations predicted a Stratus CST within 10% of the observed thickness 86% and 89% of the time for Cirrus/Stratus and Spectralis/Stratus groups, respectively, which is similar to the agreement on Stratus test-retest. The Bland-Altman limits of agreement for relative change in CST between machines (the degree of change that could be expected from measurement variability [combining within and between instrument variability]) were 21% for Cirrus and 19% for Spectralis when comparing predicted vs actual Stratus measurement. CONCLUSIONS AND RELEVANCE Reproducibility appears to be better with Spectralis than with Cirrus and Stratus. Conversion equations to transform Cirrus or Spectralis measurements to Stratus-equivalent values, within 10% of the observed Stratus thickness values appear feasible. Central subfield thickness changes beyond 10% when using the same machine or 20% when switching machines' after conversion to Stratus equivalents, are likely due to a change in retinal thickness rather than measurement error.
引用
收藏
页码:1113 / 1122
页数:10
相关论文
共 13 条
[1]   Transitioning from stratus OCT to cirrus OCT: a comparison and a proposed equation to convert central subfield macular thickness measurements in healthy subjects [J].
Abedi, Gelareh ;
Patal, Payal ;
Doros, Gheorghe ;
Subramanian, Manju L. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (09) :1353-1357
[2]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[3]   Retinal Thickness in People with Diabetes and Minimal or No Diabetic Retinopathy: Heidelberg Spectralis Optical Coherence Tomography [J].
Chalam, Kakarla V. ;
Bressler, Susan B. ;
Edwards, Allison R. ;
Berger, Brian B. ;
Bressler, Neil M. ;
Glassman, Adam R. ;
Grover, Sandeep ;
Gupta, Shailesh K. ;
Nielsen, Jared S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (13) :8154-8161
[4]   Repeatability of Spectralis OCT Measurements of Macular Thickness and Volume in Diabetic Macular Edema [J].
Comyn, Oliver ;
Heng, Ling Zhi ;
Ikeji, Felicia ;
Bibi, Kanom ;
Hykin, Philip G. ;
Bainbridge, James W. ;
Patel, Praveen J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (12) :7754-7759
[5]  
Domalpally Amitha, 2010, Ophthalmic Surg Lasers Imaging, V41 Suppl, pS34, DOI 10.3928/15428877-20100325-01
[6]   Randomized Trial Evaluating Ranibizumab Plus Prompt or Deferred Laser or Triamcinolone Plus Prompt Laser for Diabetic Macular Edema [J].
Elman, Michael J. ;
Aiello, Lloyd Paul ;
Beck, Roy W. ;
Bressler, Neil M. ;
Bressler, Susan B. ;
Edwards, Allison R. ;
Ferris, Frederick L., III ;
Friedman, Scott M. ;
Glassman, Adam R. ;
Miller, Kellee M. ;
Scott, Ingrid U. ;
Stockdale, Cynthia R. ;
Sun, Jennifer K. .
OPHTHALMOLOGY, 2010, 117 (06) :1064-U65
[7]   Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema [J].
Forooghian, Farzin ;
Cukras, Catherine ;
Meyerle, Catherine B. ;
Chew, Emily Y. ;
Wong, Wai T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4290-4296
[8]   RANDOMIZEDTRIAL EVALUATING SHORT-TERM EFFECTS OF INTRAVITREAL RANIBIZUMAB OR TRIAMCINOLONE ACETONIDE ON MACULAR EDEMA AFTER FOCAL/GRID LASER FOR DIABETIC MACULAR EDEMA IN EYES ALSO RECEIVING PANRETINAL PHOTOCOAGULATION [J].
Googe, Joseph ;
Brucker, Alexander J. ;
Bressler, Neil M. ;
Qin, Haijing ;
Aiello, Lloyd P. ;
Antoszyk, Andrew ;
Beck, Roy W. ;
Bressler, Susan B. ;
Ferris, Frederick L., III ;
Glassman, Adam R. ;
Marcus, Dennis ;
Stockdale, Cynthia R. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (06) :1009-1027
[9]   Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema [J].
Ibrahim, M. A. ;
Sepah, Y. J. ;
Symons, R. C. A. ;
Channa, R. ;
Hatef, E. ;
Khwaja, A. ;
Bittencourt, M. ;
Heo, J. ;
Do, D. V. ;
Nguyen, Q. D. .
EYE, 2012, 26 (03) :454-462
[10]   Conversion of Stratus optical coherence tomography (OCT) retinal thickness to Cirrus OCT values in age-related macular degeneration [J].
Krebs, Ilse ;
Hagen, Stefan ;
Smretschnig, Eva ;
Womastek, Irene ;
Brannath, Werner ;
Binder, Susanne .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (11) :1552-1554