Reproducibility of Spectral-Domain Optical Coherence Tomography Retinal Thickness Measurements and Conversion to Equivalent Time-Domain Metrics in Diabetic Macular Edema

被引:77
|
作者
Bressler, Susan B. [1 ]
Edwards, Allison R. [2 ]
Chalam, Kakarla V. [3 ]
Bressler, Neil M. [1 ]
Glassman, Adam R. [2 ]
Jaffe, Glenn J. [4 ]
Melia, Michele [2 ]
Saggau, David D. [5 ]
Plous, Oren Z. [6 ]
机构
[1] Johns Hopkins Univ, Sch Med, Wilmer Eye Inst, Baltimore, MD 21205 USA
[2] Jaeb Ctr Hlth Res, Tampa, FL 33647 USA
[3] Univ Florida, Coll Med, Hlth Sci Ctr Jacksonville, Dept Ophthalmol, Jacksonville, FL USA
[4] Duke Univ, Dept Ophthalmol, Durham, NC USA
[5] Wolfe Eye Clin, Des Moines, IA USA
[6] Gulf Coast Retina Ctr, Port Richey, FL USA
基金
美国国家卫生研究院;
关键词
OCT; VOLUME;
D O I
10.1001/jamaophthalmol.2014.1698
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE Understanding measurement variability and relationships between measurements obtained on different optical coherence tomography (OCT) machines is critical for clinical trials and clinical settings. OBJECTIVE To evaluate the reproducibility of retinal thickness measurements from OCT images obtained by time-domain (TD) (Stratus; Carl Zeiss Meditec) and spectral-domain (SD) (Cirrus; Carl Zeiss Meditec, and Spectralis; Heidelberg Engineering) instruments and formulate equations to convert retinal thickness measurements from SD-OCT to equivalent values on TD-OCT. DESIGN SETTING, AND PARTICIPANT A cross-sectional observational study was conducted in private and institutional practices. Persons with diabetes mellitus who had at least 1 eye with central-involved diabetic macular edema, defined as Stratus central subfield thickness (CST) of 250 pm or greater, participated. An additional normative cohort (individuals with diabetes but without diabetic macular edema) was enrolled. Each study eye underwent 2 replicate Stratus scans followed by 2 replicate Cirrus or Spectralis scans (real-time image registration used) centered on the fovea. MAIN OUTCOMES AND MEASURES Optical coherence tomography CST and macular volume, RESULTS The Bland-Altman coefficient of repeatability for relative change in CST (the degree of change that could be expected from measurement variability) was lower with Spectralis (7%) compared with Cirrus (14%) and Stratus (12% and 15% within Cirrus/Stratus and Spectralis/Stratus groups, respectively). For each cohort, the initial Stratus CST was within 10% of the replicate Stratus measurement nearly all of the time; the conversion equations predicted a Stratus CST within 10% of the observed thickness 86% and 89% of the time for Cirrus/Stratus and Spectralis/Stratus groups, respectively, which is similar to the agreement on Stratus test-retest. The Bland-Altman limits of agreement for relative change in CST between machines (the degree of change that could be expected from measurement variability [combining within and between instrument variability]) were 21% for Cirrus and 19% for Spectralis when comparing predicted vs actual Stratus measurement. CONCLUSIONS AND RELEVANCE Reproducibility appears to be better with Spectralis than with Cirrus and Stratus. Conversion equations to transform Cirrus or Spectralis measurements to Stratus-equivalent values, within 10% of the observed Stratus thickness values appear feasible. Central subfield thickness changes beyond 10% when using the same machine or 20% when switching machines' after conversion to Stratus equivalents, are likely due to a change in retinal thickness rather than measurement error.
引用
收藏
页码:1113 / 1122
页数:10
相关论文
共 50 条
  • [1] Comparison of Macular Thickness in Diabetic Macular Edema Using Spectral-Domain Optical Coherence Tomography and Time-Domain Optical Coherence Tomography
    Kakinoki, Masashi
    Miyake, Taichirou
    Sawada, Osamu
    Sawada, Tomoko
    Kawamura, Hajime
    Ohji, Masahito
    JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [2] Time-domain and spectral-domain optical coherence tomography in uveitic macular edema
    Roesel, Martin
    Henschel, Andreas
    Heinz, Carsten
    Spital, Georg
    Heiligenhaus, Arnd
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (04) : 626 - 627
  • [3] Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diabetic macular edema
    Patel, Nishal
    Chowdhury, Haziq
    Leung, Richard
    Sivaprasad, Sobha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (05) : 208 - 212
  • [4] Time-domain and spectral-domain optical coherence tomography in uveitic macular edema - Reply
    Gupta, Vishali
    Gupta, Pawan
    Gupta, Amod
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (04) : 627 - 628
  • [5] Segmentational Diurnal Analysis of Retinal Thickness in Diabetic Macular Edema with Spectral-domain Optical Coherence Tomography
    Sagong, Min
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Sensitivity and Specificity of Time-Domain versus Spectral-Domain Optical Coherence Tomography in the Diagnosis of Diabetic Macular Edema
    Patel, N.
    Chowdhury, H. R.
    Leung, R.
    Sivaprasad, S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [7] Reproducibility of Optovue RTVue Optical Coherence Tomography Retinal Thickness Measurements and Conversion to Equivalent Zeiss Stratus Metrics in Diabetic Macular Edema
    Bressler, Susan B.
    Edwards, Allison R.
    Andreoli, Christopher M.
    Edwards, Paul Andrew
    Glassman, Adam R.
    Jaffe, Glenn J.
    Melia, Michele
    Sun, Jennifer K.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2015, 4 (01):
  • [8] Repeatability and Reproducibility of Spectral-Domain Optical Coherence Tomography Measurements of Retinal Thickness in Rats
    Yang, Ji Ho
    Yu, Seung-Young
    Kim, Tae Gi
    Seo, Kyung Hoon
    Kwak, Hyung Woo
    CURRENT EYE RESEARCH, 2016, 41 (10) : 1346 - 1352
  • [9] Reproducibility of Spectral-Domain Optical Coherence Tomography Total Retinal Thickness Measurements in Mice
    Gabriele, Michelle L.
    Ishikawa, Hiroshi
    Schuman, Joel S.
    Bilonick, Richard A.
    Kim, Jongsick
    Kagemann, Larry
    Wollstein, Gadi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6519 - 6523
  • [10] Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema
    Ibrahim, M. A.
    Sepah, Y. J.
    Symons, R. C. A.
    Channa, R.
    Hatef, E.
    Khwaja, A.
    Bittencourt, M.
    Heo, J.
    Do, D. V.
    Nguyen, Q. D.
    EYE, 2012, 26 (03) : 454 - 462