Breast cancer screening using digital breast tomosynthesis compared to digital mammography alone for Japanese women

被引:3
作者
Ban, Kanako [1 ]
Tsunoda, Hiroko [2 ]
Togashi, Seiko [1 ]
Kawaguchi, Yuko [1 ]
Sato, Takanobu [1 ]
Takahashi, Yoko [1 ]
Nagatsuka, Yoshitaka [1 ]
机构
[1] Tokyo Hlth Serv Assoc, Shinjuku Ku, 1-2 Ichigaya Sadohara Cho, Tokyo 1628402, Japan
[2] St Lukes Int Hosp, Chuo Ku, 9-1 Akashi Cho, Tokyo 1048560, Japan
关键词
Breast cancer screening; Mammography; Digital breast tomosynthesis; 3D mammography; SYNTHESIZED 2-DIMENSIONAL MAMMOGRAPHY; IMPLEMENTATION; COMBINATION; IMAGES;
D O I
10.1007/s12282-020-01180-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background The purpose of this study is to confirm the position of DBT in breast cancer screening in Japan, to assess cancer detection rates, recall rates, positive predictive value (PPV), and to evaluate the type of mammographic findings of cancer with the use of digital mammography alone (2DDM) and combined with digital breast tomosynthesis (DBT). Methods 11,894 examinations of the opportunistic breast cancer screening using only 2DDM and 2DDM plus DBT were performed from May 1, 2017 to March 31, 2019. The 11,894 women [3535 women who received DBT in addition to 2DDM (3D group) and 8359 who received 2DDM only (2D group)] participated in this study. The study was approved by the Institute's Ethics Committee and all participants provided written informed consent. Results The recall rate was 2.6% for the 3D group and 3.6% for the 2D group (p < 0.01). The cancer detection rate was 0.17% in both 3D and 2D groups (p = 0.978). The positive predictive value (PPV) was 6.5% for the 3D group and 4.7% for the 2D group (p = 0.484). The cause of the decrease in recall rate was due to a decrease in the finding of focal asymmetric density (FAD). Conclusion The recall rate was improved by using DBT for breast cancer screening in Japanese women. Cancer detection rates were exactly the same in DBT and 2DDM groups, so only DBT non-inferiority could be verified. We have verified that breast cancer screening combined with DBT is useful even for Japanese women to reduce unnecessary further examination.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 17 条
[1]   Clinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population [J].
Aujero, Mireille P. ;
Gavenonis, Sara C. ;
Benjamin, Ron ;
Zhang, Zugui ;
Holt, Jacqueline S. .
RADIOLOGY, 2017, 283 (01) :70-76
[2]   Digital Breast Tomosynthesis with Synthesized Two-Dimensional Images versus Full-Field Digital Mammography for Population Screening: Outcomes from the Verona Screening Program [J].
Caumo, Francesca ;
Zorzi, Manuel ;
Brunelli, Silvia ;
Romanucci, Giovanna ;
Rella, Rossella ;
Cugola, Loredana ;
Bricolo, Paola ;
Fedato, Chiara ;
Montemezzi, Stefania ;
Houssami, Nehmat .
RADIOLOGY, 2018, 287 (01) :37-46
[3]   Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study [J].
Ciatto, Stefano ;
Houssami, Nehmat ;
Bernardi, Daniela ;
Caumo, Francesca ;
Pellegrini, Marco ;
Brunelli, Silvia ;
Tuttobene, Paola ;
Bricolo, Paola ;
Fanto, Carmine ;
Valentini, Marvi ;
Montemezzi, Stefania ;
Macaskill, Petra .
LANCET ONCOLOGY, 2013, 14 (07) :583-589
[4]   Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium [J].
Conant, Emily F. ;
Beaber, Elisabeth F. ;
Sprague, Brian L. ;
Herschorn, Sally D. ;
Weaver, Donald L. ;
Onega, Tracy ;
Tosteson, Anna N. A. ;
McCarthy, Anne Marie ;
Poplack, Steven P. ;
Haas, Jennifer S. ;
Armstrong, Katrina ;
Schnall, Mitchell D. ;
Barlow, William E. .
BREAST CANCER RESEARCH AND TREATMENT, 2016, 156 (01) :109-116
[5]   Clinical Digital Breast Tomosynthesis System: Dosimetric Characterization [J].
Feng, Steve Si Jia ;
Sechopoulos, Ioannis .
RADIOLOGY, 2012, 263 (01) :35-42
[6]   Clinical implementation of synthesized mammography with digital breast tomosynthesis in a routine clinical practice [J].
Freer, Phoebe E. ;
Riegert, Joanna ;
Eisenmenger, Laura ;
Ose, Dominik ;
Winkler, Nicole ;
Stein, Matthew A. ;
Stoddard, Gregory J. ;
Hess, Rachel .
BREAST CANCER RESEARCH AND TREATMENT, 2017, 166 (02) :501-509
[7]   Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography [J].
Friedewald, Sarah M. ;
Rafferty, Elizabeth A. ;
Rose, Stephen L. ;
Durand, Melissa A. ;
Plecha, Donna M. ;
Greenberg, Julianne S. ;
Hayes, Mary K. ;
Copit, Debra S. ;
Carlson, Kara L. ;
Cink, Thomas M. ;
Barke, Lora D. ;
Greer, Linda N. ;
Miller, Dave P. ;
Conant, Emily F. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (24) :2499-2507
[8]   Radiation dose with digital breast tomosynthesis compared to digital mammography: per-view analysis [J].
Gennaro, Gisella ;
Bernardi, D. ;
Houssami, N. .
EUROPEAN RADIOLOGY, 2018, 28 (02) :573-581
[9]  
Ohnuki K., 2019, Jpn J Breast Cancer, V34, P55
[10]   Digital Mammography versus Digital Mammography Plus Tomosynthesis for Breast Cancer Screening: The Reggio Emilia Tomosynthesis Randomized Trial [J].
Pattacini, Pierpaolo ;
Nitrosi, Andrea ;
Rossi, Paolo Giorgi ;
Iotti, Valentina ;
Ginocchi, Vladimiro ;
Ravaioli, Sara ;
Vacondio, Rita ;
Braglia, Luca ;
Cavuto, Silvio ;
Campari, Cinzia .
RADIOLOGY, 2018, 288 (02) :375-385