Numerical investigation of flow through inclined fins under the absorber plate of solar air heater

被引:37
作者
Qader, Bootan S. [1 ,3 ]
Supeni, E. E. [1 ]
Ariffin, M. K. A. [1 ]
Abu Talib, A. R. [2 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Dept Mech & Mfg Engn, Serdang 43400, Selangor, Malaysia
[2] Univ Putra Malaysia, Fac Engn, Dept Aerosp Engn, Aerodynam Heat Transfer & Prop AHTP Grp, Serdang 43400, Selangor, Malaysia
[3] Minist Municipal & Tourism, Erbil Municipal, Directorate Engn Pk Erbil, Erbil, Kurdistan Regio, Iraq
关键词
CFD; Solar air heater; Inclined fins; THPP; FRICTION FACTOR CORRELATIONS; SHAPED RIB ROUGHNESS; THERMOHYDRAULIC PERFORMANCE; TRANSFER AUGMENTATION; TRANSFER COEFFICIENT; DUCT; CHANNEL;
D O I
10.1016/j.renene.2019.04.024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The world today is going through a phase of uncertainty in terms of provision of power and energy because of shortages of fossil fuels, and these issues are increasing the costs as well as developing uncertain economic conditions worldwide. Hence, there is a dire necessity to find a solution to this problem by finding sustainable alternative power and energy solutions. However, the thermal performance of the conventional SAH is found to be poor due to low convective heat transfer coefficient between the heat collecting surface and working fluid. Therefore, increasing the convection heat transfer coefficient is essential so that thermal system performance can also be increased. In the present research, a numerical evaluation was carried out on the heat transfer and the flow friction processes in a SAH coupled with inclined fins underneath the absorber plate. With a constant heat flux application (1000 W/m(2)), the average Nusselt number (Nu) and friction factor, as well as the thermo-hydraulic performance parameter (THPP), were comprehensively investigated. The research covered different slant angle (alpha) of fins in the range of 30 degrees-75 degrees, different pitch (P) of fin in the range of 15-25 mm and a range of 4000-24000 for the Reynolds numbers (Re). For the current CFD evaluation, ANSYS FLUENT (v16.1) with renormalization group k - epsilon turbulence model is selected for computational domain analysis. In general, a significant improvement of the heat transfer in a SAH having inclined fins has been achieved. Moreover, with a view to analyzing the total effect of the slant angle and pitch of fin, the THPP subjected to similar pumping power constraint was calculated. From the investigated range, a maximum THPP of 1.916 was achieved by utilizing fins with alpha = 45 degrees and P = 20 mm at Re = 20,000. Finally, the proposed inclined fin's THPP was compared to other geometries such as, L-shaped (THPP = 1.90), square (THPP = 1.80), and circle (THPP = 1.65). As a result, a better THPP of 1.916 was observed for this study. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:468 / 481
页数:14
相关论文
共 33 条
[1]   Investigation of effect of the circular ring turbulators on heat transfer augmentation and fluid flow characteristic of solar air heater [J].
Acir, Adem ;
Ata, Ismail ;
Canli, Mehmet Emin .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 77 :45-54
[2]   A general optimized geometry of angled ribs for enhancing the thermo-hydraulic behavior of a solar air heater channel - A Taguchi approach [J].
Aghaie, Alireza Zamani ;
Rahimi, Asghar B. ;
Akbarzadeh, Alireza .
RENEWABLE ENERGY, 2015, 83 :47-54
[3]   Effect of circularity of perforation holes in V-shaped blockages on heat transfer and friction characteristics of rectangular solar air heater duct [J].
Alam, Tabish ;
Saini, R. P. ;
Saini, J. S. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 86 :952-963
[4]   Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate [J].
Bhagoria, JL ;
Saini, JS ;
Solanki, SC .
RENEWABLE ENERGY, 2002, 25 (03) :341-369
[5]   CFD based analysis of heat transfer enhancement in solar air heater provided with transverse rectangular ribs [J].
Boulemtafes-Boukadoum, A. ;
Benzaoui, A. .
TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 :761-772
[6]   Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater [J].
Chaube, A ;
Sahoo, PK ;
Solanki, SC .
RENEWABLE ENERGY, 2006, 31 (03) :317-331
[7]  
Fox R., 1998, Introduction to Fluid Mechanics
[8]   Experimental and CFD investigation of convection heat transfer in solar air heater with reverse L-shaped ribs [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
SOLAR ENERGY, 2016, 131 :275-295
[9]   Investigations on thermo-hydraulic performance of broken arc rib in a rectangular duct of solar air heater [J].
Gill, R. S. ;
Hans, V. S. ;
Singh, Sukhmeet .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 88 :20-27
[10]   Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs [J].
Hans, V. S. ;
Saini, R. P. ;
Saini, J. S. .