The evidence based practice for optimal sample quality for ammonia measurement

被引:35
作者
Nikolac, Nora [1 ]
Omazic, Jelena [1 ]
Simundic, Ana-Maria [1 ]
机构
[1] Univ Hosp Sestre Milosrdnice, Sch Med, Univ Dept Chem, Zagreb 10000, Croatia
关键词
Ammonia; Centrifugation; Phlebotomy; Preanalytical error; Storage conditions; BIOLOGICAL VARIATION; PLASMA AMMONIA; BLOOD; RECOMMENDATIONS; BIOCHEMISTRY;
D O I
10.1016/j.clinbiochem.2014.05.068
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Pre-analytical factors are a major source of variability in laboratory results. Failure to identify these factors can lead to falsely increased or decreased results and to erroneous clinical decisions. We aimed to investigate several pre-analytical factors influencing ammonia measurement, and to quantify their effect on the apparent increase in ammonia concentration. Design and methods: Blood samples were taken from 20 healthy volunteers and submitted to five different sets of conditions: placing sample on ice vs. room temperature immediately after phlebotomy; centrifugation at room temperature vs. 0 degrees C; measurement at 60 min vs. 30 min after sampling; storing sample at room temperature vs. 4 degrees C; and use of stopper (i.e. open vs. closed tube). Ammonia was measured in all samples. Additionally, alanine aminotransferase (ALT), gamma glutamyltransferase (GGT), free hemoglobin, and complete blood count were determined. Results: Samples placed on ice immediately after centrifugation, samples spun at 0 degrees C, and samples stored at 4 degrees C all had lower changes in ammonia concentration than samples with less favorable treatments (P = 0.008; P = 0.033, and P = 0.001, respectively). The observed biases exceeded clinically relevant acceptance criteria. Most of the tested parameters were significantly associated with increased ammonia. Multiple linear regression analysis identified only three variables that contributed significantly to the prediction of the dependent variable (i.e. increased NH3): ALT, GGT, and storage. Conclusion: Pre-analytical factors cause significant errors in ammonia measurement. An increase in ammonia concentration is most strongly associated with ALT and GGT activity and with storage temperature. (C) 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:991 / 995
页数:5
相关论文
共 18 条
[11]  
Nikolac N, 2013, BIOCHEM MEDICA, V23, P242
[12]  
Ricós C, 1999, SCAND J CLIN LAB INV, V59, P491
[13]   The stability of ethanol in unstoppered tubes [J].
Saracevic, Andrea ;
Simundic, Ana-Maria ;
Dukic, Lora .
CLINICAL BIOCHEMISTRY, 2014, 47 (1-2) :92-95
[14]   Bias in research [J].
Simundic, Ana-Maria .
BIOCHEMIA MEDICA, 2013, 23 (01) :12-15
[15]  
Simundic AM, 2012, BIOCHEM MEDICA, V22, P15
[16]   Valproate-associated hyperammonemic encephalopathy [J].
Wadzinski, Jim ;
Franks, Ronald ;
Roane, David ;
Bayard, Max .
JOURNAL OF THE AMERICAN BOARD OF FAMILY MEDICINE, 2007, 20 (05) :499-502
[17]   Ammonia metabolism, the brain and fatigue; revisiting the link [J].
Wilkinson, Daniel J. ;
Smeeton, Nicholas J. ;
Watt, Peter W. .
PROGRESS IN NEUROBIOLOGY, 2010, 91 (03) :200-219
[18]   Recurrent unexplained hyperammonemia in an adolescent with arginase deficiency [J].
Zhang, Yan ;
Landau, Yuval E. ;
Miller, David T. ;
Marsden, Deborah ;
Berry, Gerard T. ;
Kellogg, Mark D. .
CLINICAL BIOCHEMISTRY, 2012, 45 (18) :1583-1586