Prediction of fluid responsiveness: an update

被引:360
作者
Monnet, Xavier [1 ]
Marik, Paul E. [2 ]
Teboul, Jean-Louis [1 ]
机构
[1] Univ Paris Sud, Paris Sud Univ Hosp, Bicetre Hosp, INSERM,UMR S999,Med Intens Care Unit, 78 Rue Gen Leclerc, F-94270 Le Kremlin Bicetre, France
[2] Eastern Virginia Med Sch, Dept Med, Div Pulm & Crit Care Med, Norfolk, VA 23501 USA
关键词
Pulse pressure variation; Stroke volume variation; Pulse contour analysis; Heart-lung interactions; Passive leg raising; Fluid responsiveness; Cardiac preload; Stroke volume; Volume expansion; Fluid therapy; Haemodynamic monitoring; Critical care; Echocardiography; ICU; Operating room; PULSE PRESSURE VARIATION; CRITICALLY-ILL PATIENTS; INFERIOR VENA-CAVA; END-EXPIRATORY OCCLUSION; PLETH VARIABILITY INDEX; INCREASED INTRAABDOMINAL PRESSURE; MECHANICALLY VENTILATED PATIENTS; EXTRAVASCULAR LUNG WATER; STROKE VOLUME VARIATION; CENTRAL VENOUS-PRESSURE;
D O I
10.1186/s13613-016-0216-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
In patients with acute circulatory failure, the decision to give fluids or not should not be taken lightly. The risk of overzealous fluid administration has been clearly established. Moreover, volume expansion does not always increase cardiac output as one expects. Thus, after the very initial phase and/or if fluid losses are not obvious, predicting fluid responsiveness should be the first step of fluid strategy. For this purpose, the central venous pressure as well as other "static" markers of preload has been used for decades, but they are not reliable. Robust evidence suggests that this traditional use should be abandoned. Over the last 15 years, a number of dynamic tests have been developed. These tests are based on the principle of inducing short-term changes in cardiac preload, using heart-lung interactions, the passive leg raise or by the infusion of small volumes of fluid, and to observe the resulting effect on cardiac output. Pulse pressure and stroke volume variations were first developed, but they are reliable only under strict conditions. The variations in vena caval diameters share many limitations of pulse pressure variations. The passive leg-raising test is now supported by solid evidence and is more frequently used. More recently, the end-expiratory occlusion test has been described, which is easily performed in ventilated patients. Unlike the traditional fluid challenge, these dynamic tests do not lead to fluid overload. The dynamic tests are complementary, and clinicians should choose between them based on the status of the patient and the cardiac output monitoring technique. Several methods and tests are currently available to identify preload responsiveness. All have some limitations, but they are frequently complementary. Along with elements indicating the risk of fluid administration, they should help clinicians to take the decision to administer fluids or not in a reasoned way.
引用
收藏
页数:11
相关论文
共 90 条
[1]   Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients? [J].
Airapetian, Norair ;
Maizel, Julien ;
Alyamani, Ola ;
Mahjoub, Yazine ;
Lorne, Emmanuel ;
Levrard, Melanie ;
Ammenouche, Nacim ;
Seydi, Aziz ;
Tinturier, Francois ;
Lobjoie, Eric ;
Dupont, Herve ;
Slama, Michel .
CRITICAL CARE, 2015, 19
[2]  
[Anonymous], 2016, AM J RESP CRIT CARE
[3]  
Aya HD, 2016, CRIT CARE M IN PRESS
[4]   Fluid Therapy: Double-Edged Sword during Critical Care? [J].
Benes, Jan ;
Kirov, Mikhail ;
Kuzkov, Vsevolod ;
Lainscak, Mitja ;
Molnar, Zsolt ;
Voga, Gorazd ;
Monnet, Xavier .
BIOMED RESEARCH INTERNATIONAL, 2015, 2015
[5]   Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids? [J].
Bentzer, Peter ;
Griesdale, Donald E. ;
Boyd, John ;
MacLean, Kelly ;
Sirounis, Demetrios ;
Ayas, Najib T. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (12) :1298-1309
[6]   Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients [J].
Biais, Matthieu ;
Cottenceau, Vincent ;
Petit, Laurent ;
Masson, Francoise ;
Cochard, Jean-Francois ;
Sztark, Francois .
CRITICAL CARE, 2011, 15 (04)
[7]   Fluid accumulation, survival and recovery of kidney function in critically ill patients with acute kidney injury [J].
Bouchard, Josee ;
Soroko, Sharon B. ;
Chertow, Glenn M. ;
Himmelfarb, Jonathan ;
Ikizler, T. Alp ;
Paganini, Emil P. ;
Mehta, Ravindra L. .
KIDNEY INTERNATIONAL, 2009, 76 (04) :422-427
[8]   Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients [J].
Boulain, T ;
Achard, JM ;
Teboul, JL ;
Richard, C ;
Perrotin, D ;
Ginies, G .
CHEST, 2002, 121 (04) :1245-1252
[9]   Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality [J].
Boyd, John H. ;
Forbes, Jason ;
Nakada, Taka-aki ;
Walley, Keith R. ;
Russell, James A. .
CRITICAL CARE MEDICINE, 2011, 39 (02) :259-265
[10]  
Campaign SS, UPDATED BUNDLES RESP