Sol-gel based metal-organic framework zeolite imidazolate framework-8 fibers for solid-phase microextraction of nitro polycyclic aromatic hydrocarbons and polycyclic aromatic hydrocarbons in water samples

被引:68
|
作者
Kong, Jijie [1 ]
Zhu, Fengxi [1 ]
Huang, Wen [1 ]
He, Huan [2 ,3 ]
Hui, Jiapeng [3 ]
Sun, Cheng [1 ]
Xian, Qiming [1 ]
Yang, Shaogui [2 ]
机构
[1] Nanjing Univ, Sch Environm, State Key Lab Pollut Control & Resource Reuse, Nanjing 210023, Jiangsu, Peoples R China
[2] Nanjing Normal Univ, Sch Environm, Nanjing 210023, Jiangsu, Peoples R China
[3] Wuyi Univ, Coll Ecol & Resource Engn, Fujian Prov Key Lab Ecoind Green Technol, Wuyishan 354300, Peoples R China
基金
中国国家自然科学基金;
关键词
Zeolite imidazolate framework-8; Nitro polycyclic aromatic hydrocarbons and polycyclic aromatic hydrocarbons; Solid phase microextraction; Sol-gel technology; Gas chromatography-mass spectrometry; SITU HYDROTHERMAL GROWTH; ROOM-TEMPERATURE SYNTHESIS; STAINLESS-STEEL WIRE; COATED FIBER; SOLVOTHERMAL SYNTHESIS; LIQUID-CHROMATOGRAPHY; EXTRACTION; SORBENT; NANOTUBES; TRENDS;
D O I
10.1016/j.chroma.2019.06.063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, three kinds of Zeolite imidazolate framework-8 (ZIF-8), synthesized by solvothermal, stirring and ball-milling method, were fabricated on the stainless steel wire via sol-gel technique. These fibers were used as solid phase microextraction (SPME) coating materials and applied for analyzing 16 polycyclic aromatic hydrocarbons (PAHs) and 11 nitro polycyclic aromatic hydrocarbons (NPAHs) in environmental water samples by gas chromatography-tandem mass spectrometry (GC-MS). The optimal pH, ionic strength, extraction time, extraction temperature, desorption temperature and desorption time were 6.0, without salt addition, 45 min, 35 degrees C, 260 degrees C and 5 min, respectively. The extraction mechanism of the ZIF-8 fiber might be the hydrophobicity, molecular penetration and pi-pi stacking interactions. Under the optimized conditions, the as-proposed fiber provides a wide linearity range from 10 to 20,000 ng L-1 and a low detection limit of 0.3-27.0 ng L-1 for PAHs and NPAHs analysis. The single fiber and fiber to fiber relative standard deviations were observed in the range of 3.0%-13.9% and 3.5%-12.3%, respectively. The method shows great potential in environmental analysis field. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 101
页数:10
相关论文
共 50 条
  • [31] Zeolite Imidazolate Framework Nanocrystals Electrodeposited on Stainless Steel Fiber for Determination of Polycyclic Aromatic Hydrocarbons
    Hajializadeh, Afsaneh
    Ansari, Mehdi
    Foroughi, Mohammad Mehdi
    Jahani, Shohreh
    Kazemipour, Maryam
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2022, 41 (02): : 368 - 379
  • [32] Magnetic metal-organic framework MIL-100(Fe) microspheres for the magnetic solid-phase extraction of trace polycyclic aromatic hydrocarbons from water samples
    Du, Fuyou
    Qin, Qun
    Deng, Jianchao
    Ruan, Guihua
    Yang, Xianqing
    Li, Laihao
    Li, Jianping
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (12) : 2356 - 2364
  • [33] A sol-gel based solid phase microextraction fiber for analysis of aromatic hydrocarbons
    Farhadi, Khalil
    Mamaghanian, Maliheh
    Maleki, Ramin
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (02) : 677 - 682
  • [34] Graphitic carbon nitride derivative with large mesopores as sorbent for solid-phase microextraction of polycyclic aromatic hydrocarbons
    Feng, Zunmei
    Huang, Chuanhui
    Guo, Yuheng
    Liu, Wei
    Zhang, Lan
    TALANTA, 2020, 209
  • [35] Barium Sulfate Nanoparticles as a Coating for Solid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons in Aqueous Samples
    Jiaqing Feng
    Min Sun
    Xiuqin Wang
    Yu Tian
    Chuannan Luo
    Juanjuan Feng
    Chromatographia, 2018, 81 : 1287 - 1292
  • [36] Porous carbon derived from aluminum-based metal organic framework as a fiber coating for the solid-phase microextraction of polycyclic aromatic hydrocarbons from water and soil
    Xi Zhang
    Xiao Huan Zang
    Jun Tao Wang
    Chun Wang
    Qiu Hua Wu
    Zhi Wang
    Microchimica Acta, 2015, 182 : 2353 - 2359
  • [37] Polyoxotungstate nanoclusters supported on silica as an efficient solid-phase microextraction fiber of polycyclic aromatic hydrocarbons
    Abolghasemi, Mir Mahdi
    Yousefi, Vahid
    Rafiee, Ezzat
    MICROCHIMICA ACTA, 2014, 181 (15-16) : 1807 - 1814
  • [38] Carbon nanospheres as solid-phase microextraction coating for the extraction of polycyclic aromatic hydrocarbons from water and soil samples
    Chang, Qingyun
    Wang, Mengting
    Zhang, Guijiang
    Zang, Xiaohuan
    Li, Hongda
    Zhang, Shuaihua
    Wang, Chun
    Wang, Zhi
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (13) : 2594 - 2601
  • [39] Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples by Microwave-Assisted Headspace Solid-Phase Microextraction
    Hsieh, Ping-Chieh
    Jen, Jen-Fon
    Lee, Chon-Lin
    Chang, Kuei-Chen
    ENVIRONMENTAL ENGINEERING SCIENCE, 2015, 32 (04) : 301 - 309
  • [40] Boron nitride nanotubes as novel sorbent for solid-phase microextraction of polycyclic aromatic hydrocarbons in environmental water samples
    Meizhen Fu
    Hanzhu Xing
    Xiangfeng Chen
    Rusong Zhao
    Chunyi Zhi
    Chiman Lawrence Wu
    Analytical and Bioanalytical Chemistry, 2014, 406 : 5751 - 5754