The Direct Antiglobulin Test

被引:70
作者
Parker, Victoria [2 ]
Tormey, Christopher A. [1 ,2 ]
机构
[1] Yale Univ, Sch Med, Dept Lab Med, 333 Cedar St,POB 208035, New Haven, CT 06520 USA
[2] VA Connecticut Healthcare Syst, Pathol & Lab Med Serv, New Haven, CT 06520 USA
关键词
FLOW-CYTOMETRY; BLOOD-DONORS; ERYTHROCYTES; MANAGEMENT; HEMOLYSIS; ELUTION; IGA;
D O I
10.5858/arpa.2015-0444-RS
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The direct antiglobulin test (DAT; sometimes referred to as the ''Coombs'' test) continues to be one of the most widely used assays in laboratory medicine. First described about 70 years ago, it is elegantly simple in design, yet it is widely complex in its applications and interpretations, and it is prone to false- positive and false-negative results. The overall objective of our review is to provide practicing pathologists with a guide to identify situations when the DAT is useful and to highlight disease-specific shortcomings as well as general pitfalls of the test. To accomplish these goals, this review will discuss the following: (1) the history of the DAT, (2) how the test is performed in the clinical laboratory, (3) clinical situations for its use, (4) its interpretation, and (5) the pitfalls associated with DAT assays, including causes of false positivity.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 46 条
  • [1] Alvarez A, 2000, HAEMATOLOGICA, V85, P186
  • [2] Evaluation of the Use of Gel Card System for Assessment of Direct Coombs Test: Weighing the Pros and Cons
    Alwar, Vanamala
    Devi, A. M. Shanthala
    Sitalakshmi, S.
    Karuna, R. K.
    [J]. INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2012, 28 (01) : 15 - 18
  • [3] Simultaneous detection of IgG, IgM, IgA complexes and C3d attached to erythrocytes by flow cytometry
    Alzate, M. A.
    Manrique, L. G.
    Bolanos, N. I.
    Duarte, M.
    Coral-Alvarado, P.
    Gonzalez, J. M.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2015, 37 (03) : 382 - 389
  • [4] [Anonymous], IMM PACK INS
  • [5] [Anonymous], TRANSFUSION REACTION
  • [6] [Anonymous], ZENTRALBL BAKT
  • [7] [Anonymous], THE TECHNICAL MANUAL
  • [8] [Anonymous], 1985, LAB MED
  • [9] A Critical Review of Published Methods for Analysis of Red Cell Antigen-Antibody Reactions by Flow Cytometry, and Approaches for Resolving Problems with Red Cell Agglutination
    Arndt, Patricia A.
    Garratty, George
    [J]. TRANSFUSION MEDICINE REVIEWS, 2010, 24 (03) : 172 - 194
  • [10] Serologic findings in autoimmune hemolytic anemia associated with immunoglobulin M warm autoantibodies
    Arndt, Patricia A.
    Leger, Regina M.
    Garratty, George
    [J]. TRANSFUSION, 2009, 49 (02) : 235 - 242