Whole-body surface assessment - implementation and experiences with 360° 3D whole-body scans: opportunities to objectively monitor the extremities and the body trunk

被引:6
作者
Etzel, Lucas [1 ]
Koban, Konstantin Christoph [1 ]
Li, Zhouxiao [1 ]
Frank, Konstantin [1 ]
Giunta, Riccardo Enzo [1 ]
Schenck, Thilo Ludwig [1 ]
机构
[1] LMU Munchen, Klinikum Univ Munchen, Abt Hand Plast & Asthet Chirurg, Munich, Germany
关键词
3D surface imaging; whole-body; scanning; lipoedema; PLASTIC-SURGERY; ACCURACY; SYSTEM; VALIDATION; SYMMETRY; LIPEDEMA;
D O I
10.1055/a-0836-2683
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Three-dimensional surface imaging (3DSI) has proven to be useful in providing objective aid to the planning process and documentation of various plastic-surgical procedures. Although this technology is routinely used in the surface and volume analysis of the face and breast, it has been of limited use in registering and quantifying the resulting changes to the entire body surface. The aim of this study was the clinical implementation of 360 degrees whole-body scans to evaluate the treatment of lipoedema. Patients, materials and methods Three 3DSI devices (Eva, Thor and Sense) were tested for precision and reproducibility regarding whole-body scans. Using a standardised setup consisting of an automatic turntable and predetermined body poses, human subjects were analysed by measuring axial circumferences and quantifying defined layers of body volume. The relevant statistical and clinical deviations were subsequently evaluated. Results A standardised procedure for 360 degrees scans was successfully implemented. All tested scanners yielded sufficient results with respect to intraindividual reproducibility (p > 0.05). The Eva and Thor scanners delivered comparable results for axial circumference and volume analysis (p > 0.05). The Sense scanner allowed for a precise analysis in the area of the body trunk, but had significant deficits regarding the lower extremity (p < 0.05). The data analysis was then successfully applied to selected clinical cases. Conclusion A procedure to reproducibly capture and analyse the human body was successfully established for clinical use in plastic surgery. Two of the tested 3DSI devices allowed for an objective surface and volume analysis of the human body. The third scanner (Sense) offered the ability to perform 360 degrees scans at a low cost, albeit lacking in precision when applied to certain areas of the body. These findings may help to objectively evaluate the effects of different procedures on the entirety of the body surface in the future.
引用
收藏
页码:240 / 248
页数:9
相关论文
共 28 条
[11]   A study of scan garment accuracy and reliability [J].
Kim, Dong-Eun ;
LaBat, Karen ;
Bye, Elizabeth ;
Sohn, MyungHee ;
Ryan, Karen .
JOURNAL OF THE TEXTILE INSTITUTE, 2015, 106 (08) :853-861
[12]   Comparison of three-dimensional scanner systems for craniomaxillofacial imaging [J].
Knoops, Paul G. M. ;
Beaumont, Caroline A. A. ;
Borghi, Alessandro ;
Rodriguez-Florez, Naiara ;
Breakey, Richard W. F. ;
Rodgers, William ;
Angullia, Freida ;
Jeelani, N. U. Owase ;
Schievano, Silvia ;
Dunaway, David J. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2017, 70 (04) :441-449
[13]   En Route for Objective Evaluation of Form, Volume, and Symmetry in Plastic Surgery using 3-D Intraoperative Scans [J].
Koban, K. C. ;
Schenck, T. ;
Metz, P. M. ;
Volkmer, E. ;
Haertnagl, F. ;
Titze, V. ;
Giunta, R. E. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2016, 48 (02) :78-84
[14]   3D-Imaging and Analysis for Plastic Surgery by Smartphone and Tablet: An Alternative to Professional Systems? [J].
Koban, K. C. ;
Leitsch, S. ;
Holzbach, T. ;
Volkmer, E. ;
Metz, P. M. ;
Giunta, R. E. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2014, 46 (02) :97-104
[15]   Precision in 3-Dimensional Surface Imaging of the Face: A Handheld Scanner Comparison Performed in a Cadaveric Model [J].
Koban, Konstantin C. ;
Cotofana, Sebastian ;
Frank, Konstantin ;
Green, Jeremy B. ;
Etzel, Lucas ;
Li, Zhouxiao ;
Giunta, Riccardo E. ;
Schenck, Thilo L. .
AESTHETIC SURGERY JOURNAL, 2019, 39 (04) :NP36-NP44
[16]   Quantitative volumetric analysis of the lower extremity: validation against established tape measurement and water displacement [J].
Koban, Konstantin Christoph ;
Titze, Virginia ;
Etzel, Lucas ;
Frank, Konstantin ;
Schenck, Thilo ;
Giunta, Riccardo .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2018, 50 (06) :393-399
[17]   Validating three-dimensional imaging of the breast [J].
Losken, A ;
Seify, H ;
Denson, DD ;
Paredes, AA ;
Carlson, GW .
ANNALS OF PLASTIC SURGERY, 2005, 54 (05) :471-476
[18]   Validity of the 3D VECTRA photogrammetric surface imaging system for cranio-maxillofacial anthropometric measurements [J].
Metzler P. ;
Sun Y. ;
Zemann W. ;
Bartella A. ;
Lehner M. ;
Obwegeser J.A. ;
Kruse-Gujer A.L. ;
Lübbers H.-T. .
Oral and Maxillofacial Surgery, 2014, 18 (3) :297-304
[19]  
Modabber Ali, 2016, J Oral Maxillofac Res, V7, pe4, DOI 10.5037/jomr.2016.7404
[20]   Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning [J].
Modabber, Ali ;
Peters, Florian ;
Kniha, Kristian ;
Goloborodko, Evgeny ;
Ghassemi, Alireza ;
Lethaus, Bernd ;
Hoelzle, Frank ;
Moehlhenrich, Stephan Christian .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (10) :1719-1724