Quantification of clenbuterol in equine plasma, urine and tissue by liquid chromatography coupled on-line with quadrupole time-of-flight mass spectrometry

被引:34
作者
Guan, FY
Uboh, CE
Soma, LR
Luo, Y
Li, RB
Birks, EK
Teleis, D
Rudy, JA
Tsang, DS
机构
[1] Univ Penn, Sch Vet Med, Dept Clin Studies, Kennett Sq, PA 19348 USA
[2] W Chester Univ, Dept Chem, PA Equine Toxicol & Res Lab, W Chester, PA 19382 USA
关键词
D O I
10.1002/rcm.748
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/ 0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 mug/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1642 / 1651
页数:10
相关论文
共 38 条
[1]   COMPARISON OF TIME-RESOLVED FLUOROIMMUNOASSAY AND IMMUNOENZYMOMETRIC ASSAY FOR CLENBUTEROL [J].
BACIGALUPO, MA ;
IUS, A ;
MERONI, G ;
DOVIS, M ;
PETRUZZELLI, E .
ANALYST, 1995, 120 (08) :2269-2271
[2]   DETECTION OF CLENBUTEROL RESIDUES IN BOVINE LIVER, MUSCLE, RETINA AND URINE USING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLANCHFLOWER, WJ ;
HEWITT, SA ;
CANNAVAN, A ;
ELLIOTT, CT ;
KENNEDY, DG .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (06) :326-330
[3]   MATRIX SOLID-PHASE DISPERSION AS A MULTIRESIDUE EXTRACTION TECHNIQUE FOR BETA-AGONISTS IN BOVINE LIVER-TISSUE [J].
BOYD, D ;
OKEEFFE, M ;
SMYTH, MR .
ANALYST, 1994, 119 (07) :1467-1470
[4]   Dexamethasone and clenbuterol detection by enzyme immunoassay in bovine liver tissue: A new multiresidue extraction procedure [J].
Cerni, L ;
Biancotto, G ;
Tondolo, A ;
Bogoni, P .
FOOD AND AGRICULTURAL IMMUNOLOGY, 1998, 10 (04) :307-315
[5]  
De Wasch K, 1998, ANALYST, V123, P2701, DOI 10.1039/a805039b
[6]   DETERMINATION OF CLENBUTEROL IN BOVINE-TISSUES AND URINE BY ENZYME-IMMUNOASSAY [J].
DEGAND, G ;
BERNESDUYCKAERTS, A ;
MAGHUINROGISTER, G .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1992, 40 (01) :70-75
[7]   Detection and confirmation of beta-agonists in bovine retina using LC/APCI-MS [J].
Doerge, DR ;
Churchwell, MI ;
Holder, CL ;
Rowe, L ;
Bajic, S .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1918-1923
[8]   SCREENING AND CONFIRMATORY ANALYSIS OF BETA-AGONISTS, BETA-ANTAGONISTS AND THEIR METABOLITES IN HORSE URINE BY CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
DUMASIA, MC ;
HOUGHTON, E .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (02) :503-513
[9]   Stereoselective determination of clenbuterol in human urine by capillary electrophoresis [J].
Gausepohl, C ;
Blaschke, G .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (02) :443-446
[10]   DETERMINATION OF CLENBUTEROL IN BOVINE PLASMA AND TISSUES BY GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
GIRAULT, J ;
FOURTILLAN, JB .
JOURNAL OF CHROMATOGRAPHY, 1990, 518 (01) :41-52