A Field Study to Determine the Effectiveness of Several Respiratory Protection Masks on the Styrene Exposure during Lamination Activities

被引:5
作者
Triebig, Gerhard [1 ]
Werner, Philipp [1 ]
Zimmer, Holger [1 ]
机构
[1] Univ Heidelberg Hosp, Inst & Outpatient Clin Occupat & Social Med, D-69115 Heidelberg, Germany
关键词
Styrene; Respiratory protection masks; Effectiveness; Biological monitoring; REINFORCED-PLASTICS INDUSTRY; WORKERS; EQUIPMENT;
D O I
10.2486/indhealth.47.145
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Purpose of the study: The purpose of this study is to examine the effectiveness of several types of personal respiratory protection equipment at styrene exposed laminators under real work place conditions. Subjects and method: 99 male styrene exposed workers were examined. During their lamination activities the average styrene concentrations in air ranged between 30 to 60 ppm (maximum: 205 ppm). The laminators were followed during an usual workweek from Monday to Thursday. The external styrene exposure was measured by means of passive active carbon badges. The excretion of mandelic acid (MA) and phenyl glyoxylic acid (PGA) in end-of-shift urine samples was used to quantify the internal styrene load. During the work shift some laminators did not use respiratory protection masks. The majority used either a half face mask with active carbon filter or an air purifying respirator. Results: The respiratory masks were worn during an average between 31% and 72% of the work time. The styrene concentrations of the ambient air were -depending on the activity- in the range of 30 to 60 ppm. The end-of-shift concentrations of MA and PGA in urine samples varied considerably, their means range from 153 to 606 mg/g creatinine. The comparison shows that workers with air purifying respirators experience the lowest internal styrene body burden in spite of high external exposures. Their effectiveness during usual working condition was around 83% whereas the use of half face masks with active carbon filters reduce styrene exposure only of 26% as an average. Conclusions: The use of styrene-containing resins in boatbuilding can be associated with increased external styrene exposure of the laminators. During the use of different types of respiratory protection masks it is shown that only the application of air purifying respirators leads to a significant reduction of the internal styrene body burden of 83% when worn during 72% of the total work time. In this way it is possible to comply with or to stay clearly below the biological limit value of 600 mg MA + PGA/g creatinine (BAT-value).
引用
收藏
页码:145 / 154
页数:10
相关论文
共 17 条
  • [1] BADER M, 2000, UNTERSUCHUNG AUSSERE
  • [2] Human neurobehavioral effects of long-term exposure to styrene: A meta-analysis
    Benignus, VA
    Geller, AM
    Boyes, WK
    Bushnell, PJ
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (05) : 532 - 538
  • [3] BROOKS SM, 1980, ARCH ENVIRON HEALTH, V35, P287
  • [4] *DFG, 1996, AN METH PRUF GES ARB, V1
  • [5] *DFG, 2008, LIST MAK BAT VAL MAX
  • [6] *DFG, 1997, AN HAZ SUBST BIOL MA, V5
  • [7] DGUV, 2007, GUID OCC MED EX
  • [8] Evaluation of half-mask respirator protection in styrene-exposed workers
    Gobba, F
    Ghittori, S
    Imbriani, M
    Cavalleri, A
    [J]. INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2000, 73 (01) : 56 - 60
  • [9] Biological monitoring of styrene in FRP-making small industries in Kumamoto, Japan - Winter-summer difference and effect of protective masks in practical working conditions
    Inaoka, T
    Nagano, M
    Kitano, T
    Ushijima, K
    Minamoto, K
    Tasaki, R
    Koyanagi, A
    [J]. JOURNAL OF OCCUPATIONAL HEALTH, 2002, 44 (02) : 83 - 88
  • [10] OCCUPATIONAL EXPOSURES TO STYRENE IN DENMARK 1955-88
    JENSEN, AA
    BREUM, NO
    BACHER, J
    LYNGE, E
    [J]. AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1990, 17 (05) : 593 - 606