摘要
Purpose Component orientations and positions in total hip arthroplasty (THA) are important parameters in restoring hip function. However, measurements using plain radiographs and 2D computed tomography (CT) slices are affected by patient position during imaging. This study used 3D CT to determine whether contemporary THA restores native hip geometry. Methods Fourteen patients with unilateral THA underwent CT scan for 3D hip reconstruction. Hip models of the nonoperated side were mirrored with the implanted side to quantify the differences in hip geometry between sides. Results The study demonstrated that combined hip anteversion (sum of acetabular and femoral anteversion) and vertical hip offset significantly increased by 25.3 degrees +/- 29.3 degrees (range, -25.7 degrees to 55.9 degrees, p = 0.003) and 4.1 +/- 4.7 mm (range, -7.1 to 9.8 mm, p = 0.009) in THAs. Conclusions These data suggest that hip anatomy is not fully restored following THA compared with the contralateral native hip.
引用
收藏
页码:1577 / 1583
页数:7
相关论文
共 21 条
[1]  
Barrack Robert L, 2003, J Am Acad Orthop Surg, V11, P89
[2]   Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate? [J].
Craiovan, Benjamin ;
Renkawitz, Tobias ;
Weber, Markus ;
Grifka, Joachim ;
Nolte, Lutz ;
Zheng, Guoyan .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (10) :2009-2015
[3]   Effect of superior and superolateral relocations of the hip center on hip joint forces - An experimental and analytical analysis [J].
Doehring, TC ;
Rubash, HE ;
Shelley, FJ ;
Schwendeman, LJ ;
Donaldson, TK ;
Navalgund, YA .
JOURNAL OF ARTHROPLASTY, 1996, 11 (06) :693-703
[4]   Increased Anteversion of Press-fit Femoral Stems Compared With Anatomic Femur [J].
Emerson, Roger H., Jr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :477-481
[5]  
Girard J, 2006, J BONE JOINT SURG BR, V88B, P721, DOI 10.1302/0301-620X.88B6
[6]   TOTAL HIP AND TOTAL KNEE REPLACEMENT .2. [J].
HARRIS, WH ;
SLEDGE, CB .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (12) :801-807
[7]   Edge Loading Has a Paradoxical Effect on Wear in Metal-on-Polyethylene Total Hip Arthroplasties [J].
Harris, William H. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) :3077-3082
[8]   Using a calliper to restore the centre of the femoral head during total hip replacement [J].
Hill, J. C. ;
Archbold, H. A. P. ;
Diamond, O. J. ;
Orr, J. F. ;
Jaramaz, B. ;
Beverland, D. E. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11) :1468-1474
[9]   Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :530-534
[10]   In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours [J].
Kwon, Y-M. ;
Mellon, S. J. ;
Monk, P. ;
Murray, D. W. ;
Gill, H. S. .
BONE & JOINT RESEARCH, 2012, 1 (04) :42-49