A Novel Weighted Total Difference Based Image Reconstruction Algorithm for Few-View Computed Tomography

被引:25
|
作者
Yu, Wei [1 ,3 ]
Zeng, Li [1 ,2 ]
机构
[1] Chongqing Univ, Educ Minist China, Key Lab Optoelect Technol & Syst, Chongqing 630044, Peoples R China
[2] Chongqing Univ, Coll Math & Stat, Chongqing 630044, Peoples R China
[3] Chongqing Univ, Educ Minist China, Engn Res Ctr Ind Computed Tomog Nondestruct Testi, Chongqing 630044, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 10期
基金
中国国家自然科学基金;
关键词
LINEAR INVERSE PROBLEMS; THRESHOLDING ALGORITHM;
D O I
10.1371/journal.pone.0109345
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In practical applications of computed tomography (CT) imaging, due to the risk of high radiation dose imposed on the patients, it is desired that high quality CT images can be accurately reconstructed from limited projection data. While with limited projections, the images reconstructed often suffer severe artifacts and the edges of the objects are blurred. In recent years, the compressed sensing based reconstruction algorithm has attracted major attention for CT reconstruction from a limited number of projections. In this paper, to eliminate the streak artifacts and preserve the edge structure information of the object, we present a novel iterative reconstruction algorithm based on weighted total difference (WTD) minimization, and demonstrate the superior performance of this algorithm. The WTD measure enforces both the sparsity and the directional continuity in the gradient domain, while the conventional total difference (TD) measure simply enforces the gradient sparsity horizontally and vertically. To solve our WTD-based few-view CT reconstruction model, we use the soft-threshold filtering approach. Numerical experiments are performed to validate the efficiency and the feasibility of our algorithm. For a typical slice of FORBILD head phantom, using 40 projections in the experiments, our algorithm outperforms the TD-based algorithm with more than 60% gains in terms of the root-mean-square error (RMSE), normalized root mean square distance (NRMSD) and normalized mean absolute distance (NMAD) measures and with more than 10% gains in terms of the peak signal-to-noise ratio (PSNR) measure. While for the experiments of noisy projections, our algorithm outperforms the TD-based algorithm with more than 15% gains in terms of the RMSE, NRMSD and NMAD measures and with more than 4% gains in terms of the PSNR measure. The experimental results indicate that our algorithm achieves better performance in terms of suppressing streak artifacts and preserving the edge structure information of the object.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] 3D FEW-VIEW CT IMAGE RECONSTRUCTION WITH DEEP LEARNING
    Xie, Huidong
    Shan, Hongming
    Wang, Ge
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING WORKSHOPS (IEEE ISBI WORKSHOPS 2020), 2020,
  • [42] A fast iterative soft-threshold algorithm for few-view CT reconstruction
    Wu, Junfeng
    Mou, Xuanqin
    Zhang, Yanbo
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2012, 46 (12): : 24 - 29
  • [43] Two-stage deep learning network-based few-view image reconstruction for parallel-beam projection tomography
    Wang, Huiyuan
    Wang, Nan
    Xie, Hui
    Wang, Lin
    Zhou, Wangting
    Yang, Defu
    Cao, Xu
    Zhu, Shouping
    Liang, Jimin
    Chen, Xueli
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (04) : 2535 - +
  • [44] RISING: A new framework for model-based few-view CT image reconstruction with deep learning
    Evangelista, Davide
    Morotti, Elena
    Piccolomini, Elena Loli
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2023, 103
  • [45] An algorithm for computed tomography image reconstruction from limited-view projections
    Wang Lin-Yuan
    Li Lei
    Yan Bin
    Jiang Cheng-Shun
    Wang Hao-Yu
    Bao Shang-Lian
    CHINESE PHYSICS B, 2010, 19 (08)
  • [46] An algorithm for computed tomography image reconstruction from limited-view projections
    王林元
    李磊
    闫镔
    江成顺
    王浩宇
    包尚联
    Chinese Physics B, 2010, 19 (08) : 642 - 647
  • [47] Monte Carlo simulation of sensitivity functions for few-view computed tomography of strongly absorbing media
    Konovalov, Alexander
    Vlasov, Vitaly
    Kolchugin, Sergey
    Malyshkin, Gennady
    Mukhamadiyev, Rim
    MONTE CARLO METHODS AND APPLICATIONS, 2022, 28 (03): : 269 - 278
  • [48] Article Sparse-View Computed Tomography Reconstruction Based on a Novel Improved Prior Image Constrained Compressed Sensing Algorithm
    Li, Xuru
    Sun, Xueqin
    Li, Fuzhong
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [49] A First-Order Primal-Dual Reconstruction Algorithm for Few-View SPECT
    Wolf, Paul
    Jorgensen, Jakob H.
    Schmidt, Taly Gilat
    Sidky, Emil Y.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2381 - 2385
  • [50] Investigation of fragment reconstruction accuracy with in situ few-view flash x-ray high-speed computed tomography (HSCT)
    Moser, Stefan
    Nau, Siegfried
    Heusinger, Victoria
    Fiederle, Michael
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (06)