A Novel Weighted Total Difference Based Image Reconstruction Algorithm for Few-View Computed Tomography

被引:25
|
作者
Yu, Wei [1 ,3 ]
Zeng, Li [1 ,2 ]
机构
[1] Chongqing Univ, Educ Minist China, Key Lab Optoelect Technol & Syst, Chongqing 630044, Peoples R China
[2] Chongqing Univ, Coll Math & Stat, Chongqing 630044, Peoples R China
[3] Chongqing Univ, Educ Minist China, Engn Res Ctr Ind Computed Tomog Nondestruct Testi, Chongqing 630044, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 10期
基金
中国国家自然科学基金;
关键词
LINEAR INVERSE PROBLEMS; THRESHOLDING ALGORITHM;
D O I
10.1371/journal.pone.0109345
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In practical applications of computed tomography (CT) imaging, due to the risk of high radiation dose imposed on the patients, it is desired that high quality CT images can be accurately reconstructed from limited projection data. While with limited projections, the images reconstructed often suffer severe artifacts and the edges of the objects are blurred. In recent years, the compressed sensing based reconstruction algorithm has attracted major attention for CT reconstruction from a limited number of projections. In this paper, to eliminate the streak artifacts and preserve the edge structure information of the object, we present a novel iterative reconstruction algorithm based on weighted total difference (WTD) minimization, and demonstrate the superior performance of this algorithm. The WTD measure enforces both the sparsity and the directional continuity in the gradient domain, while the conventional total difference (TD) measure simply enforces the gradient sparsity horizontally and vertically. To solve our WTD-based few-view CT reconstruction model, we use the soft-threshold filtering approach. Numerical experiments are performed to validate the efficiency and the feasibility of our algorithm. For a typical slice of FORBILD head phantom, using 40 projections in the experiments, our algorithm outperforms the TD-based algorithm with more than 60% gains in terms of the root-mean-square error (RMSE), normalized root mean square distance (NRMSD) and normalized mean absolute distance (NMAD) measures and with more than 10% gains in terms of the peak signal-to-noise ratio (PSNR) measure. While for the experiments of noisy projections, our algorithm outperforms the TD-based algorithm with more than 15% gains in terms of the RMSE, NRMSD and NMAD measures and with more than 4% gains in terms of the PSNR measure. The experimental results indicate that our algorithm achieves better performance in terms of suppressing streak artifacts and preserving the edge structure information of the object.
引用
收藏
页数:10
相关论文
共 50 条
  • [22] Accurate image reconstruction from few-view and limited-angle data in diffraction tomography
    LaRoque, Samuel J.
    Sidky, Emil Y.
    Pan, Xiaochuan
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (07) : 1772 - 1782
  • [23] Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model
    Wolf, Paul A.
    Jorgensen, Jakob S.
    Schmidt, Taly G.
    Sidky, Emil Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16): : 5629 - 5652
  • [24] Few-view CT reconstruction via a novel non-local means algorithm
    Chen, Zijia
    Qi, Hongliang
    Wu, Shuyu
    Xu, Yuan
    Zhou, Linghong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (10): : 1276 - 1283
  • [25] Multigrid Iterative Method with Adaptive Spatial Support for Computed Tomography Reconstruction from Few-View Data
    Lee, Ping-Chang
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [26] FBP Initialized Few-view CT Reconstruction Algorithm Using Similar Prior Image Constraint
    Zhang, Weikang
    Li, Jiansen
    Sun, Jianqi
    Zhao, Jun
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 3949 - 3952
  • [27] A study on projection distribution of few-view reconstruction with total variation constraint
    Zhang, Li
    Duan, Xinhui
    Xing, Yuxiang
    Chen, Zhiqiang
    Cheng, Jianping
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [28] A resolution-enhancing image reconstruction method for few-view differential phase-contrast tomography
    Guan, Huifeng
    Anastasio, Mark A.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [29] Data Driven Tight Frames Regularization for Few-view Image Reconstruction
    Li, Jie
    Zhang, Wenkun
    Zhang, Hanming
    Li, Lei
    Yan, Bin
    2017 13TH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, FUZZY SYSTEMS AND KNOWLEDGE DISCOVERY (ICNC-FSKD), 2017, : 815 - 820
  • [30] Artificial neural network enhanced total generalized variation regularization few-view CT image reconstruction
    Li, Kuai
    Wu, Haoying
    PROCEEDINGS OF 2019 IEEE 8TH JOINT INTERNATIONAL INFORMATION TECHNOLOGY AND ARTIFICIAL INTELLIGENCE CONFERENCE (ITAIC 2019), 2019, : 1601 - 1605