Comparison of Flat Field Correction Methods for Photon-Counting Spectral CT Images

被引:0
作者
Kim, Donghyeok [1 ,2 ,3 ]
Baek, Jongduk [1 ,2 ]
机构
[1] Yonsei Univ, Sch Integrated Technol, Incheon, South Korea
[2] Yonsei Univ, Yonsei Inst Convergence Technol, Incheon, South Korea
[3] Samsung Elect, DR R&D Grp, Hlth & Med Equipment Business, Suwon, South Korea
来源
2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC) | 2018年
基金
新加坡国家研究基金会;
关键词
PULSE PILEUP; RAY; DETECTOR;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For the practical usage of the photon-counting detector (PCD) in medical imaging, conductor material stability, photon counting efficiency, and energy separation accuracy must reach a certain level. Besides the pulse pile-up phenomenon, PCD has a non-linear response of the incident X-ray energies, and thus without proper energy calibration, the reconstructed images produce significant ring artifacts. In this study, we propose a water gain correction method for energy calibration of the PCD. To calculate the gain of each detector pixel, we measured the ratio of the sinogram between a water cylinder phantom and an ideal water cylinder phantom, and then averaged the ratio over all views. Then, this gain was multiplied to the projection data acquired from the traditional flat field correction method. The performance of the proposed method was compared to flat field correction methods that use averaged air shots and scan data of a water cylinder phantom. Our results show that the proposed method reduces the ring artifacts effectively without increasing the noise in the final image. It is also observed that the proposed method provides improved SNR and CNR by 45 to 55% compared to the flat field correction using scan data of a water cylinder phantom.
引用
收藏
页数:3
相关论文
共 12 条
[1]   Assessment of a photon-counting detector for a dual-energy C-arm angiographic system [J].
Ahmad, Moiz ;
Fahrig, Rebecca ;
Pung, Leland ;
Spahn, Martin ;
Koester, Niko S. ;
Reitz, Silke ;
Moore, Teri ;
Choi, Jang-Hwan ;
Hinshaw, Waldo ;
Xia, Yan ;
Mueller, Kerstin .
MEDICAL PHYSICS, 2017, 44 (11) :5938-5948
[2]   Raw data normalization for a multi source inverse geometry CT system [J].
Baek, Jongduk ;
De Man, Bruno ;
Harrison, Daniel ;
Pelc, Norbert J. .
OPTICS EXPRESS, 2015, 23 (06) :7514-7526
[3]   Image-based spectral distortion correction for photon-counting x-ray detectors [J].
Ding, Huanjun ;
Molloi, Sabee .
MEDICAL PHYSICS, 2012, 39 (04) :1864-1876
[4]   An improved method for flat-field correction of flat panel x-ray detector [J].
Kwan, ALC ;
Seibert, JA ;
Boone, JM .
MEDICAL PHYSICS, 2006, 33 (02) :391-393
[5]   Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors [J].
Le, Huy Q. ;
Ducote, Justin L. ;
Molloi, Sabee .
MEDICAL PHYSICS, 2010, 37 (03) :1225-1236
[6]   How does real offset and gain correction affect the DQE in images from X-ray flat detectors? [J].
Moy, JP ;
Bosset, B .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :90-97
[7]   Flat-field correction technique for digital detectors [J].
Seibert, JA ;
Boone, JM ;
Lindfors, KK .
PHYSICS OF MEDICAL IMAGING, 1998, 3336 :348-354
[8]   Energy-sensitive photon counting detector-based X-ray computed tomography [J].
Taguchi K. .
Radiological Physics and Technology, 2017, 10 (1) :8-22
[9]   Vision 20/20: Single photon counting x-ray detectors in medical imaging [J].
Taguchi, Katsuyuki ;
Iwanczyk, Jan S. .
MEDICAL PHYSICS, 2013, 40 (10) :100901
[10]   Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects [J].
Taguchi, Katsuyuki ;
Zhang, Mengxi ;
Frey, Eric C. ;
Wang, Xiaolan ;
Iwanczyk, Jan S. ;
Nygard, Einar ;
Hartsough, Neal E. ;
Tsui, Benjamin M. W. ;
Barber, William C. .
MEDICAL PHYSICS, 2011, 38 (02) :1089-1102