Reliability of timed walking tests and temporo-spatial gait parameters in youths with neurological gait disorders

被引:36
作者
Graser, Judith V. [1 ,2 ,3 ]
Letsch, Claudia [1 ,4 ]
van Hedel, Hubertus J. A. [1 ,2 ,3 ]
机构
[1] Univ Childrens Hosp Zurich, Rehabil Ctr, Paediat Rehab Res Grp, Affoltern Am Albis, Switzerland
[2] Univ Childrens Hosp Zurich, Childrens Res Ctr, Zurich, Switzerland
[3] Neurosci Ctr Zurich ZNZ, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Inst Human Movement Sci & Sports, Zurich, Switzerland
关键词
Gait capacity; 6 Minute walk test; 10 Meter walk test; Paediatric neurorehabilitation; Psychometric properties; GAITRite; Gait symmetry; Child; Cerebral palsy; TEST-RETEST RELIABILITY; CEREBRAL-PALSY; CHILDREN; EPIDEMIOLOGY; VALIDITY;
D O I
10.1186/s12883-016-0538-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The 10-Meter Walk Tests (10MWT) and the 6-Minute Walk Test (6MinWT) are applied to assess gait capacity in paediatric patients. To better objectify changes in qualitative aspects of gait, temporo-spatial parameters like stride length or step symmetry could be simultaneously assessed with a GAITRite system. Reliability has not yet been evaluated in a heterogeneous sample of children with various neurological gait disorders such as is representative for paediatric neuro-rehabilitation. The aim of this study was to assess test-retest reliability of the 10MWT, the 6MinWT and simultaneously recorded gait parameters captured with the GAITRite system in children with neurological gait disorders. Methods: This is a cross-sectional study with two measurement time-points. Thirty participants (9 females; mean (standard deviation) age 13.0 (3.6) years, 10 with cerebral palsy, 6 after stroke, among other diagnoses) performed the 10MWT at preferred (10MWTpref) and maximum speed (10MWTmax) and the 6MinWT on two occasions (mean time interval: 7.0 (1.9) days). Relative reliability was quantified with an intra-class correlation coefficient (ICC); the measurement error reflecting absolute reliability was quantified with the standard error of measurement and the smallest real difference. Results: ICCs of timed walking tests (time measured with a stopwatch, step count for the 10MWT and walking distance for the 6MinWT) ranged from 0.89-0.97. ICCs of temporo-spatial gait parameters ranged from 0.81-0.95 (10MWTpref), from 0.61-0.90 (10MWTmax) and from 0.88-0.97 (6MinWT). In general, absolute reliability was greatest in the 6MinWT. Conclusion: Timed walking tests and temporo-spatial gait parameters obtained from the GAITRite system appear reliable in children with neurological gait disorders. However, especially in children with poorer walking ability, the reliability of temporo-spatial parameters might have been positively influenced, as unclear steps had to be removed using the GAITRite software. As absolute reliability is rather low, the responsiveness of these measures needs to be further evaluated.
引用
收藏
页数:12
相关论文
共 31 条
  • [1] Balzer J, 2015, DEV MED CHILD NEUROL
  • [2] The Six-Minute Walk Test in Chronic Pediatric Conditions: A Systematic Review of Measurement Properties
    Bartels, Bart
    de Groot, Janke F.
    Terwee, Caroline B.
    [J]. PHYSICAL THERAPY, 2013, 93 (04): : 529 - 541
  • [3] Gait symmetry improves in childhood-A 4-year follow-up of foot loading data
    Bosch, Kerstin
    Rosenbaum, Dieter
    [J]. GAIT & POSTURE, 2010, 32 (04) : 464 - 468
  • [4] Influence of virtual reality soccer game on walking performance in robotic assisted gait training for children
    Bruetsch, Karin
    Schuler, Tabea
    Koenig, Alexander
    Zimmerli, Lukas
    Merillat , Susan
    Luenenburger, Lars
    Riener, Robert
    Jaencke, Lutz
    Meyer-Heim, Andreas
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2010, 7
  • [5] Reliability of videotaped observational gait analysis in patients with orthopedic impairments
    Brunnekreef, JJ
    van Uden, CJT
    van Moorsel, S
    Kooloos, JGM
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2005, 6 (1)
  • [6] Carter R, 2005, REHABILITATION RES P
  • [7] ATS statement: Guidelines for the six-minute walk test
    Crapo, RO
    Casaburi, R
    Coates, AL
    Enright, PL
    MacIntyre, NR
    McKay, RT
    Johnson, D
    Wanger, JS
    Zeballos, RJ
    Bittner, V
    Mottram, C
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (01) : 111 - 117
  • [8] Six-minute walk test in children and adolescents with cystic fibrosis
    Cunha, Maristela Trevisan
    Rozov, Tatiana
    de Oliveira, Rosangela Caitano
    Jardim, Jose R.
    [J]. PEDIATRIC PULMONOLOGY, 2006, 41 (07) : 618 - 622
  • [9] Reproducibility of Maximal and Submaximal Exercise Testing in "Normal Ambulatory" and "Community Ambulatory" Children and Adolescents With Spina Bifida: Which Is Best for the Evaluation and Application of Exercise Training?
    de Groot, Janke Frederike
    Takken, Tim
    Gooskens, Rob H. J. M.
    Schoenmakers, Marja A. G. C.
    Wubbels, Manon
    Vanhees, Luc
    Helders, Paul J. M.
    [J]. PHYSICAL THERAPY, 2011, 91 (02): : 267 - 276
  • [10] When to use agreement versus reliability measures
    de Vet, Henrica C. W.
    Terwee, Caroline B.
    Knol, Dirk L.
    Bouter, Lex M.
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2006, 59 (10) : 1033 - 1039