Sensitive voltammetric determination of neohesperidin dihydrochalcone based on SWNTs modified glassy carbon electrode

被引:1
|
作者
Yang, Lingxi [1 ]
Wang, Lu [1 ,2 ]
Li, Kunjing [1 ]
Ye, Baoxian [1 ]
机构
[1] Zhengzhou Univ, Coll Chem & Mol Engn, Zhengzhou 450001, Peoples R China
[2] Luoyang Inst Sci & Technol, Dept Environm Engn & Chem, Luoyang 471023, Peoples R China
基金
中国国家自然科学基金;
关键词
LIQUID-CHROMATOGRAPHY; FLAVONOIDS; ADSORPTION; FOODSTUFFS; NARINGIN;
D O I
10.1039/c4ay02004a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new voltammetric sensor, based on single-walled carbon nanotubes (SWNTs) modified glassy carbon electrode, was established and used for the determination of neohesperidin dihydrochalcone (NHDC). The electrochemical characterization of NHDC on this sensor was studied systematically by cyclic voltammetry, and the kinetics parameters were calculated for the first time. Compared with a bare GCE, the proposed sensor exhibited excellent redox activity towards NHDC, and a new voltammetric analytical method for NHDC was proposed with a wide linear range from 5 x 10(-8) mol L-1 to 8 x 10(-6) mol L-1 and a low detection limit of 2 x 10(-8) mol L-1. In addition, a reasonable mechanism was also proposed and discussed. Finally, the developed method was successfully applied for the quantitative determination of NHDC in beverages with high accuracy and satisfactory recovery results.
引用
收藏
页码:9410 / 9418
页数:9
相关论文
共 50 条
  • [31] Sensitive Adsorption Stripping Voltammetric Determination of Reserpine by a Glassy Carbon Electrode Modified with Multi-Wall Carbon Nanotubes
    Huajie Zhang
    Kangbing Wu
    Microchimica Acta, 2005, 149 : 73 - 78
  • [32] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    ANALYST, 2002, 127 (01) : 129 - 134
  • [33] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &
  • [34] Voltammetric determination of paracetamol on the glassy carbon electrode
    毕淑云
    王桂芬
    朴元哲
    王大力
    殷晓萍
    延边大学学报(自然科学版), 2000, (02) : 110 - 112
  • [35] Voltammetric Determination of Caffeine at Pt/Carbon Nanotubes Composite Modified Glassy Carbon Electrode
    Wei, Yingliang
    Zhang, Luping
    Shao, Chen
    Li, Chao
    CHEMIA ANALITYCZNA, 2009, 54 (04): : 607 - 617
  • [36] Highly Sensitive and Selective Voltammetric Sensor Fullerene Modified Glassy Carbon Electrode for Determination of Cefitizoxime in Solubilized System
    Jain, Rajeev
    Rather, Jahangir Ahmad
    Dwivedi, Ashish
    Vikas
    ELECTROANALYSIS, 2010, 22 (21) : 2600 - 2606
  • [37] Voltammetric sensitive determination of metronidazole at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Saglikoglu, Gulsen
    Yilmaz, Selehattin
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2015, 51 (09) : 862 - 866
  • [38] Sensitive Voltammetric Determination of Paracetamol on Poly(4-Aminobenzene Sulfonic Acid) Modified Glassy Carbon Electrode
    Yilmaz, Selehattin
    Bas, Zeynep
    Sadikoglu, Murat
    Yagmur, Sultan
    Saglikoglu, Gulsen
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (07): : 6244 - 6255
  • [39] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [40] Voltammetric sensitive determination of metronidazole at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Gulsen Saglikoglu
    Selehattin Yilmaz
    Russian Journal of Electrochemistry, 2015, 51 : 862 - 866