Electrochemical determination of lead ion with DNA oligonucleotide-based biosensor using anionic redox marker

被引:23
作者
Bala, Agnieszka [1 ]
Pietrzak, Mariusz [1 ]
Gorski, Lukasz [1 ]
Malinowska, Elzbieta [1 ]
机构
[1] Warsaw Univ Technol, Fac Chem, Dept Microbioanalyt, Inst Biotechnol, PL-00664 Warsaw, Poland
关键词
Electrochemical sensor; DNA-based biosensor; Metal ion determination; G-QUADRUPLEX; SENSORS; LIGANDS; PB2+;
D O I
10.1016/j.electacta.2015.08.162
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The development of DNA-modified electrodes for the determination of lead cation is described. The performance of anionic (AQMS) and cationic (methylene blue) redox markers for this aim is compared. It is shown that the use of anionic marker results in a significantly better analytical parameters, as compared to measurements with cationic marker. The optimized sensor distinguishes itself with high selectivity towards lead cation and lower detection limit of 0.42 10(-8) mol dm(-3). The interaction between lead ion and DNA strands were studied using electrochemical impedance spectroscopy (EIS) and surface plasmon resonance with imaging (SPRi). (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:763 / 769
页数:7
相关论文
共 22 条
[1]  
Babkina S.S., 2003, J ANAL CHEM+, V58, P731
[2]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[3]  
Erdem A, 2001, ELECTROANAL, V13, P219, DOI 10.1002/1521-4109(200103)13:3<219::AID-ELAN219>3.0.CO
[4]  
2-7
[5]   dsDNA modified carbon nanofiber-solidified paste electrodes: probing Ni(II)-dsDNA interactions [J].
Ferancova, Adriana ;
Rassaei, Liza ;
Marken, Frank ;
Labuda, Jan ;
Sillanpaa, Mika .
MICROCHIMICA ACTA, 2010, 170 (1-2) :155-164
[6]   Using receptor conformational change to detect low molecular weight analytes by surface plasmon resonance [J].
Gestwicki, JE ;
Hsieh, HV ;
Pitner, JB .
ANALYTICAL CHEMISTRY, 2001, 73 (23) :5732-5737
[7]   Y-type, C-rich DNA probe for electrochemical detection of silver ion and cysteine [J].
Gong, He ;
Li, Xiaohong .
ANALYST, 2011, 136 (11) :2242-2246
[8]   A G-quadruplex based label-free fluorescent biosensor for lead ion [J].
Guo, Liangqia ;
Nie, Dandan ;
Qiu, Chunyan ;
Zheng, Qishan ;
Wu, Haiyan ;
Ye, Peirong ;
Hao, Yanli ;
Fu, FengFu ;
Chen, Guonan .
BIOSENSORS & BIOELECTRONICS, 2012, 35 (01) :123-127
[9]   A regenerative electrochemical sensor based on oligonucleotide for the selective determination of mercury(II) [J].
Han, Donghoon ;
Kim, Yang-Rae ;
Oh, Jeong-Wook ;
Kim, Tae Hyun ;
Mahajan, Rakesh Kumar ;
Kim, Jong Seung ;
Kim, Hasuck .
ANALYST, 2009, 134 (09) :1857-1862
[10]   Electrochemical oligonucleotide-based biosensor for the determination of lead ion [J].
Jarczewska, Marta ;
Kierzkowska, Ewa ;
Ziolkowski, Robert ;
Gorski, Lukasz ;
Malinowska, Elzbieta .
BIOELECTROCHEMISTRY, 2015, 101 :35-41