Indirect zirconia-reinforced lithium silicate ceramic CAD/CAM restorations: Preliminary clinical results after 12 months

被引:21
作者
Zimmermann, Moritz [1 ]
Koller, Christina [2 ]
Mehl, Albert [1 ]
Hickel, Reinhard [2 ]
机构
[1] Univ Zurich, Ctr Dent Med, Dept Computerized Restorat Dent, Plattenstr 11, CH-8032 Zurich, Switzerland
[2] Univ Munich, Dept Restorat Dent & Periodontol, Marchioninistr 15, D-81377 Munich, Germany
来源
QUINTESSENCE INTERNATIONAL | 2017年 / 48卷 / 01期
关键词
CAD/CAM; CEREC; clinical study; zirconia-reinforced lithium silicate ceramic; WORLD DENTAL FEDERATION; CRITERIA; RECOMMENDATIONS; EXAMPLES; UPDATE; CROWNS;
D O I
10.3290/j.qi.a37017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: No clinical data are available for the new computer-aided design/computer-assisted manufacture (CAD/CAM) material zirconia-reinforced lithium silicate (ZLS) ceramic. This study describes preliminary clinical results for indirect ZLS CAD/CAM restorations after 12 months. Method and Materials: Indirect restorations were fabricated, using the CEREC method and intraoral scanning (CEREC Omnicam, CEREC MCXL). Sixty-seven restorations were seated adhesively (baseline). Sixty restorations were evaluated after 12 months (follow-up), using modified FDI criteria. Two groups were established, according to ZLS restorations' post-processing procedure prior to adhesive seating: group I (three-step polishing, n = 32) and group II (fire glazing, n = 28). Statistical ana-lysis was performed with Mann-Whitney U test and Wilcoxon test (P <.05). Results: The success rate of indirect ZLS CAD/CAM restorations after 12 months was 96.7%. Two restorations clinically failed as a result of bulk fracture (failure rate 3.3%). No statistically significant differences were found for baseline and follow-up criteria (Wilcoxon test, P >.05). Statistically significant differences were found for criteria surface gloss for group I and group II (Mann-Whitney U test, P <.05). Conclusion: This study demonstrates ZLS CAD/CAM restorations have a high clinical success rate after 12 months. A longer clinical evaluation period is necessary to draw further conclusions.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 19 条
[1]  
Ahlers M O, 2009, Int J Comput Dent, V12, P309
[2]  
Brown D, 1998, Dent Update, V25, P23
[3]  
Ender A, 2011, Int J Comput Dent, V14, P11
[4]   A clinical evaluation of chairside lithium disilicate CAD/CAM crowns A two-year report [J].
Fasbinder, Dennis J. ;
Dennison, Joseph B. ;
Heys, Donald ;
Neiva, Gisele .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 :10S-14S
[5]   Recommendations for conducting controlled clinical studies of dental restorative materials [J].
Hickel, R. ;
Roulet, J. -F. ;
Bayne, S. ;
Heintze, S. D. ;
Mjor, I. A. ;
Peters, M. ;
Rousson, V. ;
Randall, R. ;
Schmalz, G. ;
Tyas, M. ;
Vanherle, G. .
CLINICAL ORAL INVESTIGATIONS, 2007, 11 (01) :5-33
[6]  
Hickel R, 2007, J ADHES DENT, V9, P121
[7]   FDI World Dental Federation - Clinical Criteria for the Evaluation of Direct and Indirect Restorations Update and Clinical Examples [J].
Hickel, Reinhard ;
Peschke, Arnd ;
Tyas, Martin ;
Mjoer, Ivar ;
Bayne, Stephen ;
Peters, Mathilde ;
Hiller, Karl-Anton ;
Randall, Ross ;
Vanherle, Guido ;
Heintze, Siegward D. .
JOURNAL OF ADHESIVE DENTISTRY, 2010, 12 (04) :259-272
[8]   FDI World Dental Federation: clinical criteria for the evaluation of direct and indirect restorations-update and clinical examples [J].
Hickel, Reinhard ;
Peschke, Arnd ;
Tyas, Martin ;
Mjoer, Ivar ;
Bayne, Stephen ;
Peters, Mathilde ;
Hiller, Karl-Anton ;
Randall, Ross ;
Vanherle, Guido ;
Heintze, Siegward D. .
CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) :349-366
[9]  
Kappert HF, 2005, DENT MAT CURRICULUM, P607
[10]  
Kappert HF, 2008, FULLCERAMIC SYSTEMS, V1, P326