Quantification in proteomics through stable isotope coding: A review

被引:272
作者
Julka, S [1 ]
Regnier, F [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
quantification; expression; post-translational modifications; protein; protein interactions; single amino acid polymorphism; absolute quantification;
D O I
10.1021/pr0340734
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review focuses on techniques for quantification and identification in proteomics by stable isotope coding. Methods are examined for analyzing expression, post-translational modifications, protein:protein interactions, single amino acid polymorphism, and absolute quantification. The bulk of the quantification literature in proteomics focuses on expression analysis, where a wide variety of methods targeting different features of proteins are described. Methods for the analysis of post-translational modification (PTM) focus primarily on phosphorylation and glycosylation, where quantification is achieved in two ways, either by substitution or tagging of the PTM with an isotopically coded derivatizing agent in a single process or by coding and selecting PTM modified peptides in separate operations. Absolute quantification has been achieved by age-old internal standard methods, in which an isotopically labeled isoform of an analyte is synthesized and added to a mixture at a known concentration. One of the surprises is that isotope coding can be a valuable aid in the examination of intermolecular association of proteins through stimulus:response studies. Preliminary efforts to recognize single amino acid polymorphism are also described. The review ends with the conclusion that (1) isotope ratio analysis of protein concentration between samples does not necessarily relate directly to protein expression and rate of PTM and (2) that multiple new methods must be developed and applied simultaneously to make existing stable isotope quantification methods more meaningful. Although stable isotope coding is a powerful, wonderful new technique, multiple analytical issues must be solved for the technique to reach its full potential as a tool to Study biological systems.
引用
收藏
页码:350 / 363
页数:14
相关论文
共 176 条
  • [91] 2-M
  • [92] Yeast microarrays for genome wide parallel genetic and gene expression analysis
    Lashkari, DA
    DeRisi, JL
    McCusker, JH
    Namath, AF
    Gentile, C
    Hwang, SY
    Brown, PO
    Davis, RW
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (24) : 13057 - 13062
  • [93] Development of high-throughput liquid chromatography injected ion mobility quadrupole time-of-flight techniques for analysis of complex peptide mixtures
    Lee, YJ
    Hoaglund-Hyzera, CS
    Barnes, CAS
    Hilderbrand, AE
    Valentine, SJ
    Clemmer, DE
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 782 (1-2): : 343 - 351
  • [94] Characterization of transthyretin variants in familial transthyretin amyloidosis by mass spectrometric peptide mapping and DNA sequence analysis
    Lim, A
    Prokaeva, T
    McComb, ME
    O'Connor, PB
    Théberge, R
    Connors, LH
    Skinner, M
    Costello, CE
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (04) : 741 - 751
  • [95] Recognizing single amino acid polymorphism in proteins
    Liu, PR
    Regnier, FE
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (19) : 4956 - 4963
  • [96] An isotope coding strategy for proteomics involving both amine and carboxyl group labeling
    Liu, PR
    Regnier, FE
    [J]. JOURNAL OF PROTEOME RESEARCH, 2002, 1 (05) : 443 - 450
  • [97] MAHMOUD H, 2002, MASS SPECTROM REV, V21, P287
  • [98] Selective incorporation acids for identification proteome-wide level
    Martinovic, S
    Veenstra, TD
    Anderson, GA
    Pasa-Tolic, L
    Smith, RD
    [J]. JOURNAL OF MASS SPECTROMETRY, 2002, 37 (01): : 99 - 107
  • [99] Quantitative analysis of modified proteins by LC-MS/MS of peptides labeled with phenyl isocyanate
    Mason, DE
    Liebler, DC
    [J]. JOURNAL OF PROTEOME RESEARCH, 2003, 2 (03) : 265 - 272
  • [100] MASTERS CL, 1995, ARZNEIMITTEL-FORSCH, V45-1, P410