Increased Signal Intensity in the Dentate Nucleus on Unenhanced T1-Weighted Images After Gadobenate Dimeglumine Administration

被引:159
|
作者
Weberling, Lukas D. [1 ,2 ]
Kieslich, Pascal J. [3 ]
Kickingereder, Philipp [1 ]
Wick, Wolfgang [4 ]
Bendszus, Martin [1 ]
Schlemmer, Heinz-Peter [2 ]
Radbruch, Alexander [1 ,2 ]
机构
[1] Heidelberg Univ, Med Ctr, Dept Neuroradiol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Radiol, Heidelberg, Germany
[3] Univ Mannheim, Dept Psychol, D-68131 Mannheim, Germany
[4] Heidelberg Univ, Neurol Clin, Heidelberg, Germany
关键词
gadolinium retention; gadolinium deposition; linear gadolinium-based contrast agents; gadobenate dimeglumine; dentate nucleus; HEALTHY RATS DIFFERENCE; DEEP CEREBELLAR NUCLEI; CONTRAST AGENTS; MACROCYCLIC-AGENTS; GLOBUS-PALLIDUS; SAFETY; SPECTROSCOPY; HYPERSIGNAL; GADODIAMIDE; RETENTION;
D O I
10.1097/RLI.0000000000000206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study was to compare changes in signal intensity (SI) ratios of the dentate nucleus (DN) to pons and cerebrospinal fluid (CSF) on unenhanced T1-weighted magnetic resonance imaging (MRI) scans between the first and last MRI using the linear gadolinium-based contrast agent gadobenate dimeglumine. Materials and Methods The study was approved by the ethical committee of the University of Heidelberg (S-324/2014), and written informed consent was waived due to the retrospective character of the study. Fifty patients who underwent at least 5 consecutive MRI examinations (plus an additional last MRI for reference) with the exclusive use of gadobenate dimeglumine were analyzed retrospectively. The difference of DN-to-pons and DN-to-CSF mean SI ratios was calculated on unenhanced T1-weighted images between the first and last examination. Results were compared with previously published data on gadopentetate dimeglumine and gadoterate meglumine. Results Signal intensity ratio differences for DN-to-pons and DN-to-CSF were significantly greater than 0 (pons: 0.0399 0.0307, P < 0.001; CSF: 0.1439 +/- 0.1524, P < 0.001). No control variable consistently predicted the SI ratio difference for the DN-to-pons and the DN-to-CSF ratio. Compared with previously published data, the difference in SI increase between gadopentetate dimeglumine and gadobenate dimeglumine was not significant for the DN-to-pons ratio (P = 0.906). In contrast, the DN-to-CSF ratio difference was significantly lower (P < 0.001) for gadobenate dimeglumine. Dentate nucleus-to-pons (P < 0.001) and DN-to-CSF (P = 0.017) ratio differences were both significantly higher for gadobenate dimeglumine than for gadoterate meglumine. Conclusions The present study found an increase in SI in the DN after serial injections of gadobenate dimeglumine. Further studies are needed to clarify the potential of different linear gadolinium-based contrast agents to cause SI increase in the DN.
引用
收藏
页码:743 / 748
页数:6
相关论文
共 50 条
  • [41] Changes in signal intensity in the dentate nucleus at unenhanced T1-weighted magnetic resonance imaging depending on class of previously used gadolinium-based contrast agent
    Eileen Kasper
    Haemi Phaedra Schemuth
    Samantha Horry
    Sonja Kinner
    Pediatric Radiology, 2018, 48 : 686 - 693
  • [42] Signal intensity increases in dentate nucleus/globus pallidus/pulvinar on unenhanced T1WI MR images after multiple examinations with gadodiamide
    Koiso, Takao
    Yamamoto, Masaaki
    Watanabe, Shinya
    Barfod, Bierta E.
    NEURORADIOLOGY JOURNAL, 2019, 32 (03): : 215 - 224
  • [43] Gadolinium deposition within the paediatric brain: no increased intrinsic T1-weighted signal intensity within the dentate nucleus following the administration of a minimum of four doses of the macrocyclic agent gadobutrol
    Jonathan R. Young
    Joe Qiao
    Iren Orosz
    Noriko Salamon
    Mark A. Franke
    Hyun J. Kim
    Whitney B. Pope
    European Radiology, 2018, 28 : 4882 - 4889
  • [44] Gadolinium Deposition within the Pediatric Brain: No Increased Intrinsic T1-Weighted Signal Intensity within the Dentate Nucleus following the Administration of a Minimum of 4 Doses of the Macrocyclic Agent Gadoteridol
    Young, J. R.
    Pope, W. B.
    Bobinski, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (09) : 1604 - 1608
  • [45] Gadolinium deposition within the paediatric brain: no increased intrinsic T1-weighted signal intensity within the dentate nucleus following the administration of a minimum of four doses of the macrocyclic agent gadobutrol
    Young, Jonathan R.
    Qiao, Joe
    Orosz, Iren
    Salamon, Noriko
    Franke, Mark A.
    Kim, Hyun J.
    Pope, Whitney B.
    EUROPEAN RADIOLOGY, 2018, 28 (11) : 4882 - 4889
  • [46] Breast lesions with high signal intensity on T1-weighted MR images
    Durur-Subasi, Irmak
    Durur-Karakaya, Afak
    Alper, Fatih
    Karaman, Adem
    Kilic, Rabia Mihriban
    Sipal, Sare
    Demirci, Elif
    Akcay, Mufide Nuran
    JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (10) : 653 - 661
  • [47] Breast lesions with high signal intensity on T1-weighted MR images
    Irmak Durur-Subasi
    Afak Durur-Karakaya
    Fatih Alper
    Adem Karaman
    Rabia Mihriban Kılıc
    Sare Sipal
    Elif Demirci
    Mufide Nuran Akcay
    Japanese Journal of Radiology, 2013, 31 : 653 - 661
  • [48] Increased signal intensity in the pulvinar on T1-weighted images: A pathognomonic MR imaging sign of Fabry disease
    Moore, DF
    Ye, F
    Schiffmann, R
    Butman, JA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (06) : 1096 - 1101
  • [49] Weekly enhanced T1-weighted MRI with Gadobutrol injections in MS patients: Is there a signal intensity increase in the dentate nucleus and the globus pallidus?
    Jaulent, Paul
    Hannoun, Salem
    Kocevar, Gabriel
    Rollot, Fabien
    Durand-Dubief, Francoise
    Vukusic, Sandra
    Brisset, Jean-Christophe
    Sappey-Marinier, Dominique
    Cotton, Francois
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 204 - 208
  • [50] Effect of Exposure to Gadodiamide and Brain Irradiation on T1-Weighted Images and ADC Maps of the Dentate Nucleus
    Mallio, Carlo A.
    Parillo, Marco
    Zobel, Bruno Beomonte
    Parizel, Paul M.
    Quattrocchi, Carlo C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (05) : 1525 - 1530