Increased Signal Intensity in the Dentate Nucleus on Unenhanced T1-Weighted Images After Gadobenate Dimeglumine Administration

被引:159
|
作者
Weberling, Lukas D. [1 ,2 ]
Kieslich, Pascal J. [3 ]
Kickingereder, Philipp [1 ]
Wick, Wolfgang [4 ]
Bendszus, Martin [1 ]
Schlemmer, Heinz-Peter [2 ]
Radbruch, Alexander [1 ,2 ]
机构
[1] Heidelberg Univ, Med Ctr, Dept Neuroradiol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Radiol, Heidelberg, Germany
[3] Univ Mannheim, Dept Psychol, D-68131 Mannheim, Germany
[4] Heidelberg Univ, Neurol Clin, Heidelberg, Germany
关键词
gadolinium retention; gadolinium deposition; linear gadolinium-based contrast agents; gadobenate dimeglumine; dentate nucleus; HEALTHY RATS DIFFERENCE; DEEP CEREBELLAR NUCLEI; CONTRAST AGENTS; MACROCYCLIC-AGENTS; GLOBUS-PALLIDUS; SAFETY; SPECTROSCOPY; HYPERSIGNAL; GADODIAMIDE; RETENTION;
D O I
10.1097/RLI.0000000000000206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study was to compare changes in signal intensity (SI) ratios of the dentate nucleus (DN) to pons and cerebrospinal fluid (CSF) on unenhanced T1-weighted magnetic resonance imaging (MRI) scans between the first and last MRI using the linear gadolinium-based contrast agent gadobenate dimeglumine. Materials and Methods The study was approved by the ethical committee of the University of Heidelberg (S-324/2014), and written informed consent was waived due to the retrospective character of the study. Fifty patients who underwent at least 5 consecutive MRI examinations (plus an additional last MRI for reference) with the exclusive use of gadobenate dimeglumine were analyzed retrospectively. The difference of DN-to-pons and DN-to-CSF mean SI ratios was calculated on unenhanced T1-weighted images between the first and last examination. Results were compared with previously published data on gadopentetate dimeglumine and gadoterate meglumine. Results Signal intensity ratio differences for DN-to-pons and DN-to-CSF were significantly greater than 0 (pons: 0.0399 0.0307, P < 0.001; CSF: 0.1439 +/- 0.1524, P < 0.001). No control variable consistently predicted the SI ratio difference for the DN-to-pons and the DN-to-CSF ratio. Compared with previously published data, the difference in SI increase between gadopentetate dimeglumine and gadobenate dimeglumine was not significant for the DN-to-pons ratio (P = 0.906). In contrast, the DN-to-CSF ratio difference was significantly lower (P < 0.001) for gadobenate dimeglumine. Dentate nucleus-to-pons (P < 0.001) and DN-to-CSF (P = 0.017) ratio differences were both significantly higher for gadobenate dimeglumine than for gadoterate meglumine. Conclusions The present study found an increase in SI in the DN after serial injections of gadobenate dimeglumine. Further studies are needed to clarify the potential of different linear gadolinium-based contrast agents to cause SI increase in the DN.
引用
收藏
页码:743 / 748
页数:6
相关论文
共 50 条
  • [31] Linear gadolinium-based contrast agent (gadodiamide and gadopentetate dimeglumine)-induced high signal intensity on unenhanced T1-weighted images in pediatric patients
    Ichikawa, Shintaro
    Omiya, Yoshie
    Onishi, Hiroshi
    Motosugi, Utaroh
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (04) : 1046 - 1052
  • [32] Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children
    Maria Camilla Rossi Espagnet
    Bruno Bernardi
    Luca Pasquini
    Lorenzo Figà-Talamanca
    Paolo Tomà
    Antonio Napolitano
    Pediatric Radiology, 2017, 47 : 1345 - 1352
  • [33] Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children
    Espagnet, Maria Camilla Rossi
    Bernardi, Bruno
    Pasquini, Luca
    Figa-Talamanca, Lorenzo
    Toma, Paolo
    Napolitano, Antonio
    PEDIATRIC RADIOLOGY, 2017, 47 (10) : 1345 - 1352
  • [34] High Signal Intensity of the Cochlear Modiolus on Unenhanced T1-Weighted Images in Classical Infratentorial Superficial Siderosis
    Matsusue, Eiji
    Inoue, Chie
    Matsumoto, Kensuke
    Tanino, Tomohiko
    Nakamura, Kazuhiko
    Fujii, Shinya
    YONAGO ACTA MEDICA, 2022, 65 (04) : 270 - 277
  • [35] Repeated intravenous administration of gadobutrol does not lead to increased signal intensity on unenhanced T1-weighted images-a voxel-based whole brain analysis
    Langner, Soenke
    Kromrey, Marie-Luise
    Kuehn, Jens-Peter
    Grothe, Matthias
    Domin, Martin
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3687 - 3693
  • [36] Repeated administrations of macrocyclic gadolinium based contrast agents do not cause increased signal intensity in dentate nucleus and globus pallidus on T1-weighted unenhanced magnetic resonance images: confirmed safety in multiple sclerosis
    Sartori, A.
    Gennari, A. G.
    Zorzenon, I.
    Dinoto, A.
    Bratina, A.
    Ukmar, M.
    Bosco, A.
    Cova, M. A.
    Manganotti, P.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 1009 - 1010
  • [37] Development of High Signal Intensity within the Globus Pallidus and Dentate Nucleus following Multiple Administrations of Gadobenate Dimeglumine
    Bolles, G. M.
    Yazdani, M.
    Stalcup, S. T.
    Creeden, S. G.
    Collins, H. R.
    Nietert, P. J.
    Roberts, D. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (03) : 415 - 420
  • [38] Erratum to: Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children
    Maria Camilla Rossi Espagnet
    Bruno Bernardi
    Luca Pasquini
    Lorenzo Figà-Talamanca
    Paolo Tomà
    Antonio Napolitano
    Pediatric Radiology, 2017, 47 : 1366 - 1366
  • [39] Pediatric Brain Gadolinium Deposition in Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images Is Dependent on the Type of Contrast Agent
    Ryu, Young Jin
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, Woo-Jin
    Park, Subin
    Park, Ji Eun
    Kim, Woo Sun
    Kim, In-One
    INVESTIGATIVE RADIOLOGY, 2018, 53 (04) : 246 - 255
  • [40] Changes in signal intensity in the dentate nucleus at unenhanced T1-weighted magnetic resonance imaging depending on class of previously used gadolinium-based contrast agent
    Kasper, Eileen
    Schemuth, Haemi Phaedra
    Horry, Samantha
    Kinner, Sonja
    PEDIATRIC RADIOLOGY, 2018, 48 (05) : 686 - 693