Detection of calcium pyrophosphate dihydrate crystals in knee meniscus by dual-energy computed tomography

被引:41
作者
Tanikawa, Hidenori [1 ]
Ogawa, Ryo [2 ]
Okuma, Kazunari [3 ]
Harato, Kengo [2 ]
Niki, Yasuo [2 ]
Kobayashi, Shu [2 ]
Nagura, Takeo [4 ]
机构
[1] Saiseikai Yokohamashi Tobu Hosp, Dept Orthopaed Surg, 3-6-1 Shimosueyoshi, Yokohama, Kanagawa, Japan
[2] Keio Univ, Sch Med, Dept Orthopaed Surg, Shinjuku Ku, 35 Shinamomachi, Tokyo, Japan
[3] Saitama City Hosp, Dept Orthopaed Surg, Midori Ku, 2460 Minuma, Saitamashi, Saitama, Japan
[4] Keio Univ, Sch Med, Dept Clin Biomech, Shinjyuku Ku, 35 Shinamomachi, Tokyo, Japan
关键词
Dual-energy computed tomography; Calcium pyrophosphate; Knee joint meniscus; Pseudogout; CARTILAGE CALCIFICATION; ARTICULAR-CARTILAGE; DEPOSITION DISEASE; URIC-ACID; CT; VALIDATION; ACCURACY; GOUT;
D O I
10.1186/s13018-018-0787-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Calcium pyrophosphate dihydrate (CPPD) crystals are commonly observed in osteoarthritic joints. The aim of our study was to investigate the efficacy of a dual-energy computed tomography (DECT) for detecting CPPD crystals in knee meniscus. Methods: Twenty-six patients undergoing primary total knee arthroplasty were included in the study. Radiographs of knee joint and synovial fluid specimens were analyzed for the presence of CPPD crystals. Meniscus extracted during surgery was scanned using DECT. Sensitivity and specificity of DECT and radiograph for detecting CPPD crystals were calculated against a reference standard (polarizing light microscopy of synovial fluid aspirate). Meniscus in which CPPD crystals were suspected with DECT was further examined to confirm the crystals using a polarized microscopy. Results: CPPD crystals in synovial fluid were observed in 9 (36%) patients. The sensitivity and specificity of DECT in the detection of CPPD crystals, against microscopic identification, were 77.8 and 93.8%, respectively. The sensitivity and specificity of conventional radiography in the detection of CPPD crystals were 44.4 and 100%, respectively. DECT was able to detect the area where CPPD crystals were deposited in the meniscus. Conclusion: DECT provides good diagnostic sensitivity and specificity for detection of CPPD crystals in knee meniscus as well as spatial information about CPPD crystals. DECT is currently a research tool, but we believe that DECT can be a useful instrument to diagnose CPPD deposition disease, especially for the regions where aspiration is difficult to be performed such as pubic symphysis, atlantoaxial joint, interphalangeal joint.
引用
收藏
页数:6
相关论文
共 29 条
[1]   Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889
[2]   Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study [J].
Bongartz, Tim ;
Glazebrook, Katrina N. ;
Kavros, Steven J. ;
Murthy, Naveen S. ;
Merry, Stephen P. ;
Franz, Walter B., III ;
Michet, Clement J. ;
Veetil, Barath M. Akkara ;
Davis, John M., III ;
Mason, Thomas G., II ;
Warrington, Kenneth J. ;
Ytterberg, Steven R. ;
Matteson, Eric L. ;
Crowson, Cynthia S. ;
Leng, Shuai ;
McCollough, Cynthia H. .
ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 (06) :1072-1077
[3]   Dual energy CT in gout: a prospective validation study [J].
Choi, Hyon K. ;
Burns, Lindsay C. ;
Shojania, Kamran ;
Koenig, Nicole ;
Reid, Graham ;
Abufayyah, Mohammed ;
Law, Genevieve ;
Kydd, Alison S. ;
Ouellette, Hugue ;
Nicolaou, Savvas .
ANNALS OF THE RHEUMATIC DISEASES, 2012, 71 (09) :1466-1471
[4]  
DICHIRO G, 1979, RADIOLOGY, V130, P661
[5]   First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference [J].
Diekhoff, Torsten ;
Ziegeler, Katharina ;
Feist, Eugen ;
Kiefer, Tobias ;
Mews, Jurgen ;
Hamm, Bernd ;
Hermann, Kay-Geert A. .
SKELETAL RADIOLOGY, 2015, 44 (11) :1573-1577
[6]   Articular Cartilage Calcification in Osteoarthritis Insights Into Crystal-Induced Stress [J].
Ea, Hang-Korng ;
Nguyen, Christelle ;
Bazin, Dominique ;
Bianchi, Arnaud ;
Guicheux, Jerome ;
Reboul, Pascal ;
Daudon, Michel ;
Liote, Frederic .
ARTHRITIS AND RHEUMATISM, 2011, 63 (01) :10-18
[7]  
FISSELER-ECKHOFF A, 1992, Arthroscopy, V8, P98, DOI 10.1016/0749-8063(92)90142-X
[8]   Calcification of Articular Cartilage in Human Osteoarthritis [J].
Fuerst, M. ;
Bertrand, J. ;
Lammers, L. ;
Dreier, R. ;
Echtermeyer, F. ;
Nitschke, Y. ;
Rutsch, F. ;
Schaefer, F. K. W. ;
Niggemeyer, O. ;
Steinhagen, J. ;
Lohmann, C. H. ;
Pap, T. ;
Ruether, W. .
ARTHRITIS AND RHEUMATISM, 2009, 60 (09) :2694-2703
[9]   Investigation of calcium crystals in OA knees [J].
Fuerst, Martin ;
Lammers, L. ;
Schaefer, F. ;
Niggemeyer, O. ;
Steinhagen, J. ;
Lohmann, C. H. ;
Ruether, W. .
RHEUMATOLOGY INTERNATIONAL, 2010, 30 (05) :623-631
[10]   DETECTION OF CRYSTALS IN SYNOVIAL-FLUIDS BY LIGHT-MICROSCOPY - SENSITIVITY AND RELIABILITY [J].
GORDON, C ;
SWAN, A ;
DIEPPE, P .
ANNALS OF THE RHEUMATIC DISEASES, 1989, 48 (09) :737-742