The radiological excision of high risk and malignant lesions using the INTACT breast lesion excision system. A case series with an imaging follow up of at least 5 years

被引:11
作者
Allen, S. D. [1 ]
Osin, P. [2 ]
Nerurkar, A. [2 ]
机构
[1] Royal Marsden NHS Fdn Trust, Dept Imaging, Sutton, Surrey, England
[2] Royal Marsden NHS Fdn Trust, Dept Pathol, Sutton, Surrey, England
来源
EJSO | 2014年 / 40卷 / 07期
关键词
INTACT; BLES; Ultrasound; Stereotactic; Breast; Radiofrequency; PERCUTANEOUS EXCISION; SURGICAL EXCISION; BIOPSY; ULTRASOUND; EXPERIENCE; REMOVAL; DEVICE;
D O I
10.1016/j.ejso.2014.03.022
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the efficacy of a BLES procedure as a primary excisional biopsy rather than a surgical wide local excision for treatment of a high risk or a malignant lesion. Methods: 41 patients underwent a BLES procedure in order to attempt to remove a small breast lesion using a 15 mm or 20 mm wand from August 2007 to January 2009. The lesions were either proven on prior core biopsy to show high risk or malignant pathology or were considered to be indeterminate or suspicious on ultrasound or mammography. The pathology was reviewed to include the final status of lesion excision. If margin involvement was demonstrated then a formal surgical excision was subsequently recommended. Follow up mammography or ultrasound was performed annually in patients following the final pathological diagnosis. Results: 9 patients had a primary diagnosis of atypia (columnar cell change with atypia or atypical ductal hyperplasia (ADH)), 23 patients had ductal carcinoma in situ (DCIS) and 9 had an invasive carcinoma (IC) at the original BLES pathology. Clear BLES margins of >1 mm were obtained in 3/9 atypia lesions, 15/23 DCIS and 0/9 IC. 12/13 low grade DCIS were completely excised. Subsequent surgical margin excisions were undertaken in 20 patients. After at least 5 years of follow up (mean 66 months), 1 lesion had recurred on imaging. Conclusion: A BLES excision has potential as an alternative technique to traditional surgical wide local excision in the management of certain small breast lesions with high risk and low grade malignant potential. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:824 / 829
页数:6
相关论文
共 15 条
[1]  
Al-Harethee WA, 2013, BREAST CANC, V20
[2]   Complications of percutaneous stereotactic vacuum assisted breast biopsy system utilizing radio frequency [J].
Al-Harethee, Wasim ;
Theodoropoulos, George ;
Filippakis, Georgios Michael ;
Papapanagiotou, Ioannis ;
Matiatou, Maria ;
Georgiou, Georgia ;
Kalles, Vasileios ;
Koulocheri, Dimitra ;
Nonni, Afroditi ;
Konstadoulakis, Manousos M. ;
Manouras, Andreas ;
Zografos, George C. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) :623-626
[3]   The breast lesion excision system (BLES): a novel technique in the diagnostic and therapeutic management of small indeterminate breast lesions? [J].
Allen, Steven D. ;
Nerurkar, Ashish ;
Della Rovere, Guidabaldo U. Querci .
EUROPEAN RADIOLOGY, 2011, 21 (05) :919-924
[4]   Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision:: Utility and cost study in probably benign lesions [J].
Alonso-Bartolomé, P ;
Vega-Bolívar, A ;
Torres-Tabanera, M ;
Ortega, E ;
Acebal-Blanco, M ;
Garijo-Ayensa, F ;
Rodrigo, I ;
Muñoz-Cacho, P .
ACTA RADIOLOGICA, 2004, 45 (04) :390-396
[5]  
Gotzsche PC, 2013, LANCET, V381, P799, DOI 10.1016/S0140-6736(13)60618-2
[6]   Long-term outcome of benign fibroadenomas treated by ultrasound-guided percutaneous excision [J].
Grady, Ian ;
Gorsuch, Heidi ;
Wilburn-Bailey, Shelly .
BREAST JOURNAL, 2008, 14 (03) :275-278
[7]   Comparison of the diagnostic accuracy of a vacuum-assisted percutaneous intact specimen sampling device to a vacuum-assisted core needle sampling device for breast biopsy: Initial experience [J].
Killebrew, Larry K. ;
Oneson, Ruth H. .
BREAST JOURNAL, 2006, 12 (04) :302-308
[8]   Factors affecting the efficacy of ultrasound-guided vacuum-assisted percutaneous excision for removal of benign breast lesions [J].
Ko, Eun Young ;
Bae, Young-A ;
Kim, Min-Jeong ;
Lee, Kwan Seop ;
Lee, Yul ;
Kim, Lee Su .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (01) :65-73
[9]   Breast Lesion Excision Sample (BLES Biopsy) Combining Stereotactic Biopsy and Radiofrequency: Is it a Safe and Accurate Procedure in Case of BIRADS 4 and 5 Breast Lesions? [J].
Medjhoul, Aicha ;
Canale, Sandra ;
Mathieu, Marie-Christine ;
Uzan, Catherine ;
Garbay, Jean-Remi ;
Dromain, Clarisse ;
Balleyguier, Corinne .
BREAST JOURNAL, 2013, 19 (06) :590-594
[10]  
National Institute for Health and Care Excellence (NICE), 2006, INT PROC GUID 156