A biomechanical comparison of 3.5 locking compression plate fixation to 3.5 limited contact dynamic compression plate fixation in a canine cadaveric distal humeral metaphyseal gap model

被引:29
作者
Filipowicz, D. [1 ]
Lanz, O. [2 ]
McLaughlin, R. [3 ]
Elder, S. [4 ]
Werre, S. [4 ]
机构
[1] Virginia Polytech Inst & State Univ, Virginia Maryland Reg Coll Vet Med, Dept Small Anim Clin Sci, Blacksburg, VA 24061 USA
[2] Virginia Polytech Inst & State Univ, Virginia Maryland Reg Coll Vet Med, Dept Biomed Sci & Pathobiol, Blacksburg, VA 24061 USA
[3] Mississippi State Univ, Coll Vet Med, Dept Clin Sci, Starkville, MS USA
[4] Mississippi State Univ, Dept Agr & Biol Engn, Starkville, MS USA
关键词
Fracture model; axial compression; cyclic torsion; LCP; LC-DCP; INTERNAL FIXATOR; FRACTURES; STABILITY; IMPLANTS; BONE; STRENGTH; CATS; DOGS;
D O I
10.3415/VCOT-08-05-0042
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
3.5 locking compression plate (LCP) fixation was compared to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model. Thirty paired humeri from adult, large breed dogs were separated into equal groups based on testing: static compression, cyclic compression, and cyclic torsion. Humeral constructs stabilised with LCP were significantly stiffer than those plated with LC-DCP when loaded in static axial compression (P = 0.0004). When cyclically loaded in axial compression, the LCP constructs were significantly less stiff than the LC-DCP constructs (P = 0.0029). Constructs plated with LCP were significantly less resistant to torsion over 500 cycles than those plated with LC-DCP (P<0.0001). The increased stiffness of LCP constructs in monotonic loading compared to constructs stabilised with non-locking plates may be attributed to the stability afforded by the plate-screw interface of locking plates. The LCP constructs demonstrated less stiffness in dynamic testing in this model, likely due to plate-bone offset secondary to non-anatomic contouring and occasional incomplete seating of the locking screws when using the torque-limiting screw driver. Resolution of these aspects of LCP application may help improve the stiffness of fixation in fractures modeled by the experimental set-up of this investigation.
引用
收藏
页码:270 / 277
页数:8
相关论文
共 27 条
[1]  
Aguila AZ, 2005, VET COMP ORTHOPAED, V18, P220
[2]   Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? [J].
Ahmad, M. ;
Nanda, R. ;
Bajwa, A. S. ;
Candal-Couto, J. ;
Green, S. ;
Hui, A. C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03) :358-364
[3]   Influence of the design for fixation implants on local infection: Experimental study of dynamic compression plates versus point contact fixators in rabbits [J].
Arens, S ;
Eijer, H ;
Schlegel, U ;
Printzen, G ;
Perren, SM ;
Hansis, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (07) :470-476
[4]   EXVIVO BIOMECHANICS OF KIRSCHNER-EHMER EXTERNAL SKELETAL FIXATION APPLIED TO CANINE TIBIAE [J].
BOUVY, BM ;
MARKEL, MD ;
CHELIKANI, S ;
EGGER, EL ;
PIERMATTEI, DL ;
VANDERBY, R .
VETERINARY SURGERY, 1993, 22 (03) :194-207
[5]   Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures [J].
Charalambous, C. P. ;
Siddique, I. ;
Valluripalli, K. ;
Kovacevic, M. ;
Panose, P. ;
Srinivasan, M. ;
Marynissen, H. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (03) :205-210
[6]   Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493
[7]   Assessment of stiffness and strength of 4 different implants available for equine fracture treatment:: A study on a 20° oblique long-bone fracture model using a bone substitute [J].
Florin, M ;
Arzdorf, M ;
Linke, B ;
Auer, JA .
VETERINARY SURGERY, 2005, 34 (03) :231-238
[8]  
Frigg R, 2001, Injury, V32 Suppl 2, P63, DOI 10.1016/S0020-1383(01)00127-9
[9]   Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques [J].
Fulkerson, E ;
Egol, KA ;
Kubiak, EN ;
Liporace, F ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (04) :830-835
[10]  
Gardner Michael J, 2005, J Orthop Trauma, V19, P597, DOI 10.1097/01.bot.0000174033.30054.5f