Field vibration tests of bridge stay cables incorporated with magneto-rheological (MR) dampers

被引:27
作者
Ko, JM [1 ]
Zheng, G [1 ]
Chen, ZQ [1 ]
Ni, YQ [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Kowloon, Hong Kong, Peoples R China
来源
SMART STRUCTURES AND MATERIALS 2002: SMART SYSTEMS FOR BRIDGES, STRUCTURES, AND HIGHWAYS | 2002年 / 4696卷
关键词
bridge stay cable; vibration control; magneto-rheological (MR) damper; field vibration test; equivalent modal damping; optimal voltage input;
D O I
10.1117/12.472567
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Working towards full implementation of semi-active MR dampers to over 200 cables in the cable-stayed Dongting Lake Bridge, a few selected stay cables were installed with both MR dampers and vibration sensors for trial testing before full implementation. This paper reports the field vibration tests of a typical stay cable of 115 in long before and after being installed with MR dampers. The field vibration tests were conducted by using ambient vibration excitation, and sinusoidal excitation followed by free vibration decay, respectively. The resonant frequencies and equivalent modal damping of the first twenty in-plane modes of the cable with and without MR dampers are identified. The relationship between the equivalent modal damping ratio and the applied voltage strength to MR dampers is experimentally determined. The test results show that the modal damping ratios of the free cable without dampers conform to a combined Rayleigh and frequency-independent damping model, and are almost unvaried with vibration amplitude within the tested range. Installation of MR dampers results in a slight change of resonant frequencies in comparison with the free cable, but variation in applied voltage almost does not affect the resonant frequencies. ne equivalent modal damping ratios of the cable-damper system are found to be dependent on the installation location of MR dampers, voltage strength applied to the dampers, and the cable vibration level. The optimal voltage input, which achieves maximum system damping, is obtained for different modes under different vibration amplitudes. With optimal voltage applied to the dampers, the resulting system damping should be high enough to suppress both wind-rain-induced vibration and wake galloping of cables.
引用
收藏
页码:30 / 40
页数:11
相关论文
共 15 条
[1]   Wind- and rain-induced oscillations of cables of stayed bridges [J].
Bosdogianni, A ;
Olivari, D .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 64 (2-3) :171-185
[2]   RAIN-WIND INDUCED VIBRATIONS OF CABLES IN CABLE STAYED BRIDGES [J].
HIKAMI, Y ;
SHIRAISHI, N .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1988, 29 (1-3) :409-418
[3]   Mitigating stay cable oscillation using semiactive damping [J].
Johnson, EA ;
Baker, GA ;
Spencer, BF ;
Fujino, Y .
SMART STRUCTURES AND MATERIALS 2000: SMART SYSTEMS FOR BRIDGES, STRUCTURES, AND HIGHWAYS, 2000, 3988 :207-216
[4]  
JOHNSON EA, 1999, P 17 INT MOD AN C KI, V1, P417
[5]   Modal damping and stepping-switch control of stay cables with magnetorheological fluid dampers [J].
Lou, WJ ;
Ni, YQ ;
Ko, JM .
SMART STRUCTURES AND MATERIALS 2001: SMART SYSTEMS FOR BRIDGES, STRUCTURES, AND HIGHWAYS, 2001, 4330 :354-365
[6]   The effects of mechanical dampers on stay cables with high-damping rubber [J].
Nakamura, A ;
Kasuga, A ;
Arai, H .
CONSTRUCTION AND BUILDING MATERIALS, 1998, 12 (2-3) :115-123
[7]   Neuro-control of cable vibration using semi-active magneto-rheological dampers [J].
Ni, YQ ;
Chen, Y ;
Ko, JM ;
Cao, DQ .
ENGINEERING STRUCTURES, 2002, 24 (03) :295-307
[8]  
NI YQ, 2002, IN PRESS SMART STRUC, V4696
[9]   ESTIMATION CURVE FOR MODAL DAMPING IN STAY CABLES WITH VISCOUS DAMPER [J].
PACHECO, BM ;
FUJINO, Y ;
SULEKH, A .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (06) :1961-1979
[10]  
PERSOON AJ, 1999, WIND ENG 21 CENTURY, V2, P1019