STEAM-MiTiS: An MR Spectroscopy Method for the Detection of Scalar-Coupled Metabolites and Its Application to Glutamate at 7 T

被引:4
作者
Toncelli, Alessandra [1 ,2 ]
Noeske, Ralph [3 ]
Cosottini, Mirco [4 ,5 ]
Costagli, Mauro [5 ,6 ]
Domenici, Valentina [7 ]
Tiberi, Gianluigi [5 ,6 ]
Tosetti, Michela [5 ,6 ]
机构
[1] Univ Pisa, Ist Nazl Fis Nucl, I-56127 Pisa, Italy
[2] Univ Pisa, Dept Phys, I-56127 Pisa, Italy
[3] GE Healthcare, MR Applicat & Workflow Dev, Berlin, Germany
[4] Univ Pisa, Dipartimento Ric Traslaz & Nuove Tecnol Med & Chi, I-56127 Pisa, Italy
[5] Fdn IMAGO7, Pisa, Italy
[6] IRCCS Fdn Stella Maris, Lab Fis Med & Biotecnol Risonanza Magnet, Pisa, Italy
[7] Univ Pisa, Dipartimento Chim & Chim Ind, I-56127 Pisa, Italy
关键词
scalar-coupled metabolites; MR spectroscopy; ultra-high field; metabolite detection; MAGNETIC-RESONANCE-SPECTROSCOPY; HUMAN BRAIN; IN-VIVO; DIFFERENCE SPECTROSCOPY; RAT-BRAIN; H-1; MRS; GLUTATHIONE; FILTER; PRESS; QUANTIFICATION;
D O I
10.1002/mrm.25556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We herein present a spectroscopic technique for the detection of scalar-coupled metabolites based on stimulated echo acquisition mode (STEAM). The method is based on the time evolution of scalar-coupled metabolites at different mixing times and a constant echo time. The technique is optimized for targeting the metabolite glutamate at 7T. Methods: Numerical simulations were used to optimize the parameters to maximize the chosen metabolite signal. The maximum detection efficiency and metabolite signal as a function of echo time were used to identify the optimal parameters. In vitro and in vivo validations of the method were also performed. Results: This method canceled all the strong singlet lines and signals from macromolecules and preserved signals originating from the scalar-coupled metabolites. The subtracted spectrum was strongly simplified, but the complete spectral information of the traditional STEAM acquisition was retained in the sum spectrum. Conclusions: The simulations performed in this study were in agreement with the experimental results, and a clear detection of the metabolite of interest was obtained. The applicability in vivo was also demonstrated, with the selective detection of glutamate in human brain. This technique is simple, suitable for standard MR systems without sequence programming and could be used to detect other metabolites. (C) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1515 / 1522
页数:8
相关论文
共 41 条
[1]   Detection of Glutamate, Glutamine, and Glutathione by Radiofrequency Suppression and Echo Time Optimization at 7 Tesla [J].
An, Li ;
Li, Shizhe ;
Murdoch, James B. ;
Araneta, Maria Ferraris ;
Johnson, Christopher ;
Shen, Jun .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) :451-458
[2]   ASSIGNMENT OF RESONANCES IN THE H-1 SPECTRUM OF RAT-BRAIN BY 2-DIMENSIONAL SHIFT CORRELATED AND J-RESOLVED NMR-SPECTROSCOPY [J].
BEHAR, KL ;
OGINO, T .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :285-303
[3]   The Impact of Gabapentin Administration on Brain GABA and Glutamate Concentrations: A 7T 1H-MRS Study [J].
Cai, Kejia ;
Nanga, Ravi P. R. ;
Lamprou, Lisa ;
Schinstine, Claudia ;
Elliott, Mark ;
Hariharan, Hari ;
Reddy, Ravinder ;
Epperson, C. Neill .
NEUROPSYCHOPHARMACOLOGY, 2012, 37 (13) :2764-2771
[4]   Measurement of brain glutamate and glutamine by spectrally-selective refocusing at 3 tesla [J].
Choi, C ;
Coupland, NJ ;
Bhardwaj, PP ;
Malykhin, N ;
Gheorghiu, D ;
Allen, PS .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :997-1005
[5]   Improvement of resolution for brain coupled metabolites by optimized 1H MRS at 7 T [J].
Choi, Changho ;
Dimitrov, Ivan E. ;
Douglas, Deborah ;
Patel, Aditya ;
Kaiser, Lana G. ;
Amezcua, Carlos A. ;
Maher, Elizabeth A. .
NMR IN BIOMEDICINE, 2010, 23 (09) :1044-1052
[6]   Measurement of glutathione in human brain at 3T using an improved double quantum filter in vivo [J].
Choi, Changho ;
Zhao, Chenguang ;
Dimitrov, Ivan ;
Douglas, Deborah ;
Coupland, Nicholas J. ;
Kalra, Sanjay ;
Hawesa, Halima ;
Davis, Jeannie .
JOURNAL OF MAGNETIC RESONANCE, 2009, 198 (02) :160-166
[7]  
de Graaf R.A., 2007, IN VIVO NMR SPECTROS, DOI [DOI 10.1002/9780470512968, 10.1002/9781119382461, DOI 10.1002/9781119382461]
[8]  
de Graaf RA, 2001, CONCEPT MAGNETIC RES, V13, P32, DOI 10.1002/1099-0534(2001)13:1<32::AID-CMR4>3.0.CO
[9]  
2-J
[10]   Elevated Pontine and Putamenal GABA Levels in Mild-Moderate Parkinson Disease Detected by 7 Tesla Proton MRS [J].
Emir, Uzay E. ;
Tuite, Paul J. ;
Oez, Guelin .
PLOS ONE, 2012, 7 (01)