PELVIC RADIOTHERAPY FOR CANCER OF THE CERVIX: IS WHAT YOU PLAN ACTUALLY WHAT YOU DELIVER?

被引:99
作者
Lim, Karen [1 ,2 ]
Kelly, Valerie [1 ,2 ]
Stewart, James [1 ,2 ]
Xie, Jason [1 ,2 ]
Cho, Young-Bin [1 ,2 ]
Moseley, Joanne [1 ,2 ]
Brock, Kristy [1 ,2 ,3 ]
Fyles, Anthony [1 ,2 ,4 ]
Lundin, Anna [5 ]
Rehbinder, Henrik [5 ]
Milosevic, Michael [1 ,2 ,4 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Hlth Network, Ontario Canc Inst, Toronto, ON, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[4] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[5] RaySearch Labs AB, Stockholm, Sweden
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2009年 / 74卷 / 01期
关键词
Cervical cancer; Intensity-modulated radiotherapy; IMRT; Magnetic resonance imaging; MRI; Organ movement dosimetry; MODULATED RADIATION-THERAPY; LATE TOXICITY; LYMPH-NODES; BONE-MARROW; TUMOR; IMRT; DELINEATION; ORGANS; TARGET; MRI;
D O I
10.1016/j.ijrobp.2008.12.043
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Whole pelvic intensity-modulated radiotherapy (IMRT) is increasingly being used to treat cervix cancer and other gynecologic tumors. However, tumor and normal organ movement during treatment can substantially detract from the benefits of this approach. This study explored the effect of internal anatomic changes on the dose delivered to the tumor and organs at risk using a strategy integrating deformable soft-tissue modeling with simulated dose accumulation. Methods and Materials: Twenty patients with cervix cancer underwent baseline and weekly pelvic magnetic resonance imaging during treatment. Interfraction organ motion and delivered (accumulated) dose was modeled for three treatment scenarios: four-field box, large-margin whole pelvic IMRT (20-mm planning target volume, but 10 mm inferiorly) and small-margin IMRT (5-mm planning target volume). Results: Individually, the planned dose was not the same as the simulated delivered dose; however, when taken as a group, this was not statistically significant for the four-field box and large-margin IMRT plans. The small-margin IMRT plans yielded adequate target coverage in most patients; however, significant target underdosing occurred in I patient who displayed excessive, unpredictable internal target movement. The delivered doses to the organs at risk were significantly reduced with the small-margin plan, although substantial variability was present among the patients. Conclusion: Simulated dose accumulation might provide a more accurate depiction of the target and organ at risk coverage during fractionated whole pelvic IMRT for cervical cancer. The adequacy of primary tumor coverage using 5-mm planning target volume margins is contingent on the use of daily image-guided setup. (C) 2009 Elsevier Inc.
引用
收藏
页码:304 / 312
页数:9
相关论文
共 16 条
[1]   Intensity-modulated radiation therapy after hysterectomy: Comparison with conventional treatment and sensitivity of the normal-tissue-sparing effect to margin size [J].
Ahamad, A ;
D'Souza, W ;
Salehpour, M ;
Iyer, R ;
Tucker, SL ;
Jhingran, A ;
Eifel, PJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :1117-1124
[2]   IMRT dose escalation for positive para-aortic lymph nodes in patients with locally advanced cervical cancer while reducing dose to bone marrow and other organs at risk [J].
Ahmed, RS ;
Kim, RY ;
Duan, J ;
Meleth, S ;
De Los Santos, JF ;
Fiveash, JB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02) :505-512
[3]   Comparison of late toxicity between continuous low-dose-rate and pulsed-dose-rate brachytherapy in cervical cancer patients [J].
Bachtiary, B ;
Dewitt, A ;
Pintilie, M ;
Jezioranski, J ;
Ahonen, S ;
Levin, W ;
Manchul, L ;
Yeung, I ;
Milosevic, M ;
Fyles, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (04) :1077-1082
[4]   Inter- and intrafractional tumor and organ movement in patients with cervical cancer undergoing radiotherapy: A cinematic-MRI point-of-interest study [J].
Chan, Philip ;
Dinniwell, Robert ;
Haider, Masoom A. ;
Cho, Young-Bin ;
Jaffray, David ;
Lockwood, Gina ;
Levin, Wilfred ;
Manchul, Lee ;
Fyles, Anthony ;
Milosevic, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (05) :1507-1515
[5]   Systematic evaluation of MRI findings in different stages of treatment of cervical cancer:: Potential of MRI on delineation of target, pathoanatomic structures, and organs at risk [J].
Dimopoulos, JCA ;
Schard, G ;
Berger, D ;
Lang, S ;
Goldner, G ;
Helbich, T ;
Pötter, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05) :1380-1388
[6]   Concomitant chemotherapy and radiation therapy for cancer of the uterine cervix - art. no. CD00225.pub2 [J].
Green, J ;
Kirwan, J ;
Tierney, J ;
Vale, C ;
Symonds, P ;
Fresco, L ;
Williams, C ;
Collingwood, M .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2005, (03)
[7]  
*INT COMM RAD UN M, 1999, 62 ICRU INT COMM RAD
[8]  
*INT COMM RAD UN M, 1993, 50 ICRU INT COMM RAD
[9]   A systematic review of acute and late toxicity of concomitant chemoradiation for cervical cancer [J].
Kirwan, JM ;
Symonds, P ;
Greene, JA ;
Tierney, J ;
Collingwood, M ;
Williams, CJ .
RADIOTHERAPY AND ONCOLOGY, 2003, 68 (03) :217-226
[10]   Cervical cancer regression measured using weekly magnetic resonance imaging during fractionated radiotherapy: Radiobiologic modeling and correlation with tumor hypoxia [J].
Lim, Karen ;
Chan, Philip ;
Dinniwell, Robert ;
Fyles, Anthony ;
Haider, Masoom ;
Cho, Young-Bin ;
Jaffray, David ;
Manchul, Lee ;
Levin, Wilfred ;
Hill, Richard P. ;
Milosevic, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01) :126-133