Concept for 3D measurement of corneal donor tissue using a clinical OCT

被引:0
作者
Maeurer, Stephanie [1 ]
Asi, Fatema [3 ]
Rawer, Antonia [1 ,2 ]
Damian, Angela [1 ]
Seitz, Berthold [3 ]
Langenbucher, Achim [1 ]
Eppig, Timo [1 ,4 ]
机构
[1] Univ Saarland, Inst Expt Ophthalmol, Kirrberger Str 100,Geb 22, D-66421 Homburg, Saar, Germany
[2] Tech Univ Clausthal, Clausthal Zellerfeld, Germany
[3] Univ Klinikum Saarlandes, Klin Augenheilkunde, Homburg, Saar, Germany
[4] AMIPLANT GmbH, Schnaittach, Germany
来源
OPHTHALMOLOGE | 2019年 / 116卷 / 07期
关键词
Eye banks; Transplant; Donor cornea; Quality control; Optical coherence tomography; PRIOR REFRACTIVE SURGERY; IN-SITU KERATOMILEUSIS; ENDOTHELIAL KERATOPLASTY; PENETRATING KERATOPLASTY; SCREENING METHODS; PREVIOUS LASIK; TRANSPLANTATION; TOMOGRAPHY; SLITLAMP; SECTION;
D O I
10.1007/s00347-018-0801-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeWe present aconcept for non-contact tomographic measurement and characterization of corneal donor tissue within the cell culture medium. The purpose is to screen corneal tissue for pathologies or alterations after refractive surgery.MethodsImage acquisition is performed with the clinical anterior segment optical coherence tomography (OCT) Casia2 (Tomey Corp., Nagoya, Japan). An edge detection of the anterior and posterior surfaces of the donor cornea is performed after preprocessing and noise reduction of the data. Asphero-cylindrical surface model is then fitted to the detected surfaces in order to determine the radius of curvature, the surface refractive values, the keratometer readings and central thickness of the cornea. A cornea phantom with defined geometry was used to validate the algorithm and finally 74donor corneas were measured in the cell culture flask.ResultsThe large axial measurement range of the OCT enables measurement of the phantom and tissue samples within the culture flask with adiameter of approximately 7mm. The developed program reliably removes artifacts caused by the wall of the flask and those originating from the tissue holder and facilitates calculation of the sphero-cylindrical model for the anterior and posterior surfaces. The measurement results for the phantom show minimal deviations from the manufacturer's data. The measured radius of curvature of the corneas was within normal limits.ConclusionThe anterior OCT Casia2 enables rapid 3-dimensional measurement of corneal donor tissue in the culture medium. The measurable range covers approximately 7mm of the graft diameter, which is mainly limited by the holder used for the donor tissue. Topographical and pachymetric parameters could be derived from the volume data.
引用
收藏
页码:640 / 646
页数:7
相关论文
共 32 条
  • [11] Swelling of the Human Cornea Revealed by High-Speed, Ultrahigh-Resolution Optical Coherence Tomography
    Hutchings, Natalie
    Simpson, Trefford L.
    Hyun, Chulho
    Moayed, Alireza A.
    Hariri, Sepideh
    Sorbara, Luigina
    Bizheva, Kostadinka
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (09) : 4579 - 4584
  • [12] In Vitro Corneal Tomography of Donor Cornea Using Anterior Segment OCT
    Janunts, Edgar
    Langenbucher, Achim
    Seitz, Berthold
    [J]. CORNEA, 2016, 35 (05) : 647 - 653
  • [13] Donor Corneas Misidentified with Prior Laser In Situ Keratomileusis
    Kang, Shin Jeong
    Schmack, Ingo
    Edelhauser, Henry F.
    Grossniklaus, Hans E.
    [J]. CORNEA, 2010, 29 (06) : 670 - 673
  • [14] Detection of ectatic corneal diseases based on Pentacam
    Lopes, Bernardo T.
    Ramos, Isaac C.
    Dawson, Daniel G.
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (02): : 136 - 142
  • [15] Maharana P, 2014, OPTOMETRY VISION SCI, V91, pE59, DOI 10.1097/OPX.0000000000000162
  • [16] Darkfield biomicrography of eye bank donor corneas
    Merin, LM
    Brown, MF
    Howdeshell, LL
    [J]. CORNEA, 2001, 20 (02) : 210 - 213
  • [17] Two cases of a penetrating keratoplasty with tissue from a donor who had undergone LASIK surgery
    Michaeli-Cohen, A
    Lambert, AC
    Coloma, F
    Rootman, DS
    [J]. CORNEA, 2002, 21 (01) : 111 - 113
  • [18] Penetrating keratoplasty using tissue from a donor with previous LASIK surgery
    Mifflin, M
    Kim, M
    [J]. CORNEA, 2002, 21 (05) : 537 - 538
  • [19] Slitlamp, specular, and light microscopic findings of human donor corneas after laser-assisted in situ keratomileusis
    Mootha, VV
    Dawson, D
    Kumar, A
    Gleiser, J
    Qualls, C
    Albert, DM
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (05) : 686 - 692
  • [20] Descemet Stripping Automated Endothelial Keratoplasty Using Donor Corneas With Previous Laser In Situ Keratomileusis or Photorefractive Keratectomy: A Case Series and Donor Cap Histopathology
    Moshirfar, Majid
    Khalifa, Yousuf M.
    Davis, Don
    Fenzl, Carlton R.
    Espandar, Ladan
    Chang, JoAnn C.
    Mamalis, Nick
    Mifflin, Mark D.