Concept for 3D measurement of corneal donor tissue using a clinical OCT

被引:0
作者
Maeurer, Stephanie [1 ]
Asi, Fatema [3 ]
Rawer, Antonia [1 ,2 ]
Damian, Angela [1 ]
Seitz, Berthold [3 ]
Langenbucher, Achim [1 ]
Eppig, Timo [1 ,4 ]
机构
[1] Univ Saarland, Inst Expt Ophthalmol, Kirrberger Str 100,Geb 22, D-66421 Homburg, Saar, Germany
[2] Tech Univ Clausthal, Clausthal Zellerfeld, Germany
[3] Univ Klinikum Saarlandes, Klin Augenheilkunde, Homburg, Saar, Germany
[4] AMIPLANT GmbH, Schnaittach, Germany
来源
OPHTHALMOLOGE | 2019年 / 116卷 / 07期
关键词
Eye banks; Transplant; Donor cornea; Quality control; Optical coherence tomography; PRIOR REFRACTIVE SURGERY; IN-SITU KERATOMILEUSIS; ENDOTHELIAL KERATOPLASTY; PENETRATING KERATOPLASTY; SCREENING METHODS; PREVIOUS LASIK; TRANSPLANTATION; TOMOGRAPHY; SLITLAMP; SECTION;
D O I
10.1007/s00347-018-0801-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeWe present aconcept for non-contact tomographic measurement and characterization of corneal donor tissue within the cell culture medium. The purpose is to screen corneal tissue for pathologies or alterations after refractive surgery.MethodsImage acquisition is performed with the clinical anterior segment optical coherence tomography (OCT) Casia2 (Tomey Corp., Nagoya, Japan). An edge detection of the anterior and posterior surfaces of the donor cornea is performed after preprocessing and noise reduction of the data. Asphero-cylindrical surface model is then fitted to the detected surfaces in order to determine the radius of curvature, the surface refractive values, the keratometer readings and central thickness of the cornea. A cornea phantom with defined geometry was used to validate the algorithm and finally 74donor corneas were measured in the cell culture flask.ResultsThe large axial measurement range of the OCT enables measurement of the phantom and tissue samples within the culture flask with adiameter of approximately 7mm. The developed program reliably removes artifacts caused by the wall of the flask and those originating from the tissue holder and facilitates calculation of the sphero-cylindrical model for the anterior and posterior surfaces. The measurement results for the phantom show minimal deviations from the manufacturer's data. The measured radius of curvature of the corneas was within normal limits.ConclusionThe anterior OCT Casia2 enables rapid 3-dimensional measurement of corneal donor tissue in the culture medium. The measurable range covers approximately 7mm of the graft diameter, which is mainly limited by the holder used for the donor tissue. Topographical and pachymetric parameters could be derived from the volume data.
引用
收藏
页码:640 / 646
页数:7
相关论文
共 32 条
  • [1] [Anonymous], 2018, JAHR 2017
  • [2] Endothelial keratoplasty using donor tissue not suitable for full-thickness penetrating keratoplasty
    Armour, Rebecca L.
    Ousley, Paula J.
    Wall, Jennifer
    Hoar, Karen
    Stoeger, Chris
    Terry, Mark A.
    [J]. CORNEA, 2007, 26 (05) : 515 - 519
  • [3] Use of Fourier-Domain Optical Coherence Tomography to Evaluate Anterior Stromal Opacities in Donor Corneas
    Bald, Matthew R.
    Stoeger, Christopher
    Galloway, Joshua
    Tang, Maolong
    Holiman, Jeffrey
    Huang, David
    [J]. JOURNAL OF OPHTHALMOLOGY, 2013, 2013
  • [4] Refractive index measurements of poly(methyl methacrylate) (PMMA) from 0.4-1.6 μm
    Beadie, G.
    Brindza, Michael
    Flynn, Richard A.
    Rosenberg, A.
    Shirk, James S.
    [J]. APPLIED OPTICS, 2015, 54 (31) : F139 - F143
  • [5] Bundesarztekammer, 2018, DTSCH ARZTEBL, DOI [10.3238/arztebl.2018.rl_augenhornhautbank_02., DOI 10.3238/ARZTEBL.2018.RL_AUGENHORNHAUTBANK_02, 10.3238/arztebl.2018.rl_augenhornhautbank_02]
  • [6] Optical coherence tomography-based topography determination of corneal grafts in eye bank cultivation
    Damian, Angela
    Seitz, Berthold
    Langenbucher, Achim
    Eppig, Timo
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (01)
  • [7] Eppig T, 2018, CLIN APPL OCT OPHTHA
  • [8] Cornea donors who have had prior refractive surgery: data from the Eye Bank Association of America
    Fargione, Robert A.
    Channa, Prabjot
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (04) : 323 - 326
  • [9] Farias Roberta Jansen de Mello, 2005, Arq. Bras. Oftalmol., V68, P266, DOI 10.1590/S0004-27492005000200022
  • [10] Trends in Corneal Transplantation from 2001 to 2016 in Germany: A Report of the DOG-Section Cornea and its Keratoplasty Registry
    Flockerzi, Elias
    Maier, Philip
    Boehringer, Daniel
    Reinshagen, Helga
    Kruse, Friedrich
    Cursiefen, Claus
    Reinhard, Thomas
    Geerling, Gerd
    Torun, Necip
    Seitz, Berthold
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 188 : 91 - 98