Achievable dose reduction using iterative reconstruction for chest computed tomography: A systematic review

被引:49
作者
den Harder, Annemarlie M. [1 ]
Willemink, Martin J. [1 ]
de Ruiter, Quirina M. B. [2 ]
Schilham, Arnold M. R. [1 ]
Krestin, Gabriel P. [3 ]
Leiner, Tim [1 ]
de Jong, Pim A. [1 ]
Budde, Ricardo P. J. [3 ]
机构
[1] Univ Utrecht, Med Ctr, Dept Radiol, POB 85500,E01-132, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[3] Erasmus MC, Dept Radiol, NL-3000 CA Rotterdam, Netherlands
关键词
Thorax; CT; Diagnostic imaging; Imaging; Three-dimensional; Respiratory tract diseases; FILTERED BACK-PROJECTION; IMAGE QUALITY ASSESSMENT; CT; ANGIOGRAPHY; OPTIMIZATION; VOLTAGE; NOISE; 3D;
D O I
10.1016/j.ejrad.2015.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Iterative reconstruction (IR) allows for dose reduction with maintained image quality in CT imaging. In this systematic review the reported effective dose reductions for chest CT and the effects on image quality are investigated. Methods: A systematic search in PubMed and EMBASE was performed. Primary outcome was the reported local reference and reduced effective dose and secondary outcome was the image quality with IR. Both non contrast-enhanced and enhanced studies comparing reference dose with reduced dose were included. Results: 24 studies were included. The median number of patients per study was 66 (range 23-200) with in total 1806 patients. The median reported local reference dose of contrast-enhanced chest CT with FBP was 2.6 (range 1.5-21.8) mSv. This decreased to 1.4 (range 0.4-7.3) mSv at reduced dose levels using IR. With non contrast-enhanced chest CT the dose decreased from 3.4 (range 0.7-7.8) mSv to 0.9 (range 0.1-4.5) mSv. Objective mage quality and diagnostic confidence and acceptability remained the same or improved with IR compared to FBP in most studies while data on diagnostic accuracy was limited. Conclusion: Radiation dose can be reduced to less than 2 mSv for contrast-enhanced chest CT and non contrast-enhanced chest CT is possible at a submillisievert dose using IR algorithms. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2307 / 2313
页数:7
相关论文
共 46 条
  • [1] AAPM, 2008, MEASUREMENT REPORTIN
  • [2] Low-dose CT of the lung: potential value of iterative reconstructions
    Baumueller, Stephan
    Winklehner, Anna
    Karlo, Christoph
    Goetti, Robert
    Flohr, Thomas
    Russi, Erich W.
    Frauenfelder, Thomas
    Alkadhi, Hatem
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (12) : 2597 - 2606
  • [3] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [4] Combining Automatic Tube Current Modulation with Adaptive Statistical Iterative Reconstruction for Low-Dose Chest CT Screening
    Chen, Jiang-Hong
    Jin, Er-Hu
    He, Wen
    Zhao, Li-Qin
    [J]. PLOS ONE, 2014, 9 (04):
  • [5] Iterative reconstructed ultra high pitch CT pulmonary angiography with cardiac bowtie-shaped filter in the acute setting: Effect on dose and image quality
    Co, Steven J.
    Mayo, John
    Liang, Teresa
    Krzymyk, Karl
    Yousefi, Masoud
    Nicolaou, Savvas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (09) : 1571 - 1576
  • [6] Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product
    Deak, Paul D.
    Smal, Yulia
    Kalender, Willi A.
    [J]. RADIOLOGY, 2010, 257 (01) : 158 - 166
  • [7] CT screening for lung cancer: countdown to implementation
    Field, John K.
    Hansell, David M.
    Duffy, Stephen W.
    Baldwin, David R.
    [J]. LANCET ONCOLOGY, 2013, 14 (13) : E591 - E600
  • [8] Pushing the Envelope New Computed Tomography Techniques for Cardiothoracic Imaging
    Flohr, Thomas G.
    Klotz, Ernst
    Allmendinger, Thomas
    Raupach, Rainer
    Bruder, Herbert
    Schmidt, Bernhard
    [J]. JOURNAL OF THORACIC IMAGING, 2010, 25 (02) : 100 - 111
  • [9] Evaluation of radiation doses delivered in different chest CT protocols
    Gorycki, Tomasz
    Lasek, Iwona
    Kaminski, Kamil
    Studniarek, Michal
    [J]. POLISH JOURNAL OF RADIOLOGY, 2014, 79 : 1 - 5
  • [10] Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part II: Assessment of Radiologists' Preferences Using Dual Source CT
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Jin Seong
    Song, Jae-Woo
    Kim, Song Soo
    Lee, Hyun Joo
    Lim, Chae Hun
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) : 720 - 727