4-(1H-imidazol-1-yl) aniline: A new ligand of mixed-mode chromatography for antibody purification

被引:34
作者
Shi, Qing-Hong
Cheng, Zheng
Sun, Yan [1 ]
机构
[1] Tianjin Univ, Dept Biochem Engn, Sch Chem Engn & Technol, Tianjin 300072, Peoples R China
关键词
Mixed-mode chromatography; Ligand; Antibody; Purification; Dual-selectivity; Albumin; PROTEIN-A; SYNTHETIC LIGAND; ADSORPTION; EQUILIBRIUM; SEPARATION; ADSORBENT; HISTIDINE; CAPTURE;
D O I
10.1016/j.chroma.2009.06.065
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
4-(1H-imidazol-1-yl) aniline (AN) was immobilized on Sepharose CL-6B (AN-Sepharose) for use as a new ligand of mixed-mode chromatography. Adsorption equilibria of immunoglobulin G (IgG) and bovine serum albumin (BSA) to AN-Sepharose were studied at extensive pH values (4.0-8.8) and salt concentrations (0-1.0 mol/L). Static binding studies indicated that AN-Sepharose had a good salt-tolerance property for IgG adsorption up to 1.0 mol/L NaCl. This was attributed to the combined ligand-protein interactions (hydrophobic interaction, hydrogen bonding and charge transfer interaction). By contrast with BSA, AN-Sepharose showed a high binding selectivity for IgG at NaCl > 0.2 mol/L. Dynamic binding capacities (DBC) of IgG and BSA at 10% breakthrough were measured at pH 4.0-8.8 by frontal analysis chromatography. IgG had DBC values over 40 mg/mL at pH 7.0-8.8, and the maximum reached 59 mg/mL at pH 8.0. At pH 5.0, a distinct drop in DBC to 8.5 mg/mL was observed, but that for BSA kept over 22 mg/mL. The result suggested that IgG could be selectively desorbed from AN-Sepharose by decreasing pH to about 5. Therefore, compared to BSA, AN-Sepharose exhibited a dual-selectivity for IgG in both adsorption and elution. Purification of IgG from bovine serum also confirmed the dual-selectivity. IgG purity of the pooled fractions by elution at pH 4.0. 4.5 and 5.0 reached 55% and the highest purity, 80%, was obtained at pH 4.5. The average purification factor of IgG was over 25. The results indicate that AN is a promising ligand of mixed-mode chromatography for antibody Purification from a complex feedstock. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:6081 / 6087
页数:7
相关论文
共 39 条
  • [1] MEP chromatography of antibody and Fc-fusion protein using aqueous arginine solution
    Arakawa, Tsutomu
    Kita, Yoshiko
    Sato, Haruna
    Ejima, Daisuke
    [J]. PROTEIN EXPRESSION AND PURIFICATION, 2009, 63 (02) : 158 - 163
  • [2] BARTFELD NS, 1990, J BIOL CHEM, V265, P21684
  • [3] Bonner P.L. R., 2007, PROTEIN PURIFICATION
  • [4] Antibody separation by hydrophobic charge induction chromatography
    Boschetti, E
    [J]. TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) : 333 - 337
  • [5] The use of thiophilic chromatography for antibody purification: a review
    Boschetti, E
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 49 (1-3): : 361 - 389
  • [6] BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
  • [7] Characterization of BSA adsorption on mixed mode adsorbent - I. Equilibrium study in a well-agitated contactor
    Chang, Yu-Kaung
    Chou, Shin-Ying
    Liu, Jyun-Liang
    Tasi, Jung-Chin
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2007, 35 (01) : 56 - 65
  • [8] Modeling of the salt effects on hydrophobic adsorption equilibrium of protein
    Chen, J
    Sun, Y
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 992 (1-2) : 29 - 40
  • [9] Comparison of standard and new generation hydrophobic interaction chromatography resins in the monoclonal antibody purification process
    Chen, Jie
    Tetrault, Jenifer
    Ley, Arthur
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1177 (02) : 272 - 281
  • [10] Evaluation of a novel agarose-based synthetic ligand adsorbent for the recovery of antibodies from ovine serum
    Chhatre, Sunil
    Francis, Richard
    Titchener-Hooker, Nigel J.
    Newcombe, Anthony R.
    Keshavarz-Moore, Eli
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 860 (02): : 209 - 217