Application of nafion/cobalt hexacyanoferrate chemically modified electrodes for the determination of electroinactive cations by ion chromatography

被引:0
|
作者
Xu, JM [1 ]
Xian, YZ [1 ]
Shi, GY [1 ]
Li, JH [1 ]
Jin, LT [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
关键词
ion chromatography; electrochemical detection; water analysis;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An amperometric detector based on the chemical modification of Nafion and cobalt (II) hexacyanoferrate (II, III) thin Mm (Nafion/Co-CN-Fe) onto a glassy carbon (GC) electrode was firstly developed for the determination of electroinactive cations (Li+, Na+, K+, Rb+, Cs+ and NH4+) in single column ion chromatography. A set of well-defined peaks of electroinactive cation was obtained. The relative standard deviations (RSDs) of chromatographic peak height (nA) for these cations were all below 3.8%. The cations were detected conveniently in the linear concentration range of 6.0 x 10(-6)-5.0 x 10(-3) mol/L and their correlation coefficients were all above 0.99. The detection limits of the cations were 9.2 x 10(-6) mol/L for Li+, 3.4 x 10(-6) mol/L for Na+, 6.3 x 10(-7) mol/L for K+, 7.8 x 10(-7) mol/L for Rb+, 6.2 x 10(-7) mol/L for Cs+ and 6.2 x 10(-6) mol/L for NW, at a signal-noise ratio of 3. The method was quick, sensitive, simple and was successfully applied to the analysis of rainwater samples. The electrode was stable for a 2 week period of operation with no evidence of chemical or mechanical deterioration.
引用
收藏
页码:771 / 776
页数:6
相关论文
共 50 条
  • [41] THE APPLICATION OF CHEMICALLY MODIFIED ELECTRODES IN ANALYTICAL-CHEMISTRY
    DONG, SJ
    WANG, YD
    ELECTROANALYSIS, 1989, 1 (02) : 99 - 106
  • [42] Electrochemical redox processes at cobalt hexacyanoferrate modified electrodes: An in situ Raman spectroelectrochemical study
    Mazeikiene, Regina
    Niaura, Gediminas
    Malinauskas, Albertas
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 719 : 60 - 71
  • [43] Evaluation of cobalt(II)tetrapyridinoporphyrazine, cobalt(II)phthalocyanine, and cobalt(II)tetranitrophthalocyanine chemically modified electrodes
    Telesford, J
    Voegel, PD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U789 - U789
  • [44] Lead determination on MWNT/Nafion composite modified glassy carbon electrodes
    Xu, Q
    Liu, NN
    Zhu, JJ
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (11) : 1510 - 1514
  • [45] Electrocatalytical oxidation and determination of dopamine at redox polymer/nafion modified electrodes
    Ju, HX
    Ni, JG
    Gong, Y
    Chen, HY
    Leech, D
    ANALYTICAL LETTERS, 1999, 32 (15) : 2951 - 2964
  • [46] Cobalt hexacyanoferrate adsorbed on TiO2 nanoparticles and their modified glassy carbon electrodes for electrocatalytic oxidation and amperometric determination of hydrazine
    Marimuthu, Alexander
    Arunagiri, Saravanan
    Pandian, Arjun
    Kannaiyan, Pandian
    ANALYTICAL SCIENCES, 2023, 39 (07) : 1081 - 1088
  • [47] Cobalt hexacyanoferrate adsorbed on TiO2 nanoparticles and their modified glassy carbon electrodes for electrocatalytic oxidation and amperometric determination of hydrazine
    Alexander Marimuthu
    Saravanan Arunagiri
    Arjun Pandian
    Pandian Kannaiyan
    Analytical Sciences, 2023, 39 : 1081 - 1088
  • [48] SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACYANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
    Mattos, I. L.
    Padilla, F.
    Zagal, J. H.
    Falcao, E. H. L.
    Segura, R.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2011, 56 (03): : 803 - 807
  • [49] Mixed ion-exchanger chemically modified carbon paste ion-selective electrodes for determination of triprolidine hydrochloride
    Issa, Y. M.
    Abu Attia, F. M.
    Ismail, N. S.
    JOURNAL OF ADVANCED RESEARCH, 2010, 1 (01) : 79 - 85
  • [50] Determination of cations in fruit juices and purees by ion chromatography
    Trifiro, A
    Saccani, G
    Zanotti, A
    Gherardi, S
    Cavalli, S
    Reschiotto, C
    JOURNAL OF CHROMATOGRAPHY A, 1996, 739 (1-2) : 175 - 181