Application of nafion/cobalt hexacyanoferrate chemically modified electrodes for the determination of electroinactive cations by ion chromatography

被引:0
|
作者
Xu, JM [1 ]
Xian, YZ [1 ]
Shi, GY [1 ]
Li, JH [1 ]
Jin, LT [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
关键词
ion chromatography; electrochemical detection; water analysis;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An amperometric detector based on the chemical modification of Nafion and cobalt (II) hexacyanoferrate (II, III) thin Mm (Nafion/Co-CN-Fe) onto a glassy carbon (GC) electrode was firstly developed for the determination of electroinactive cations (Li+, Na+, K+, Rb+, Cs+ and NH4+) in single column ion chromatography. A set of well-defined peaks of electroinactive cation was obtained. The relative standard deviations (RSDs) of chromatographic peak height (nA) for these cations were all below 3.8%. The cations were detected conveniently in the linear concentration range of 6.0 x 10(-6)-5.0 x 10(-3) mol/L and their correlation coefficients were all above 0.99. The detection limits of the cations were 9.2 x 10(-6) mol/L for Li+, 3.4 x 10(-6) mol/L for Na+, 6.3 x 10(-7) mol/L for K+, 7.8 x 10(-7) mol/L for Rb+, 6.2 x 10(-7) mol/L for Cs+ and 6.2 x 10(-6) mol/L for NW, at a signal-noise ratio of 3. The method was quick, sensitive, simple and was successfully applied to the analysis of rainwater samples. The electrode was stable for a 2 week period of operation with no evidence of chemical or mechanical deterioration.
引用
收藏
页码:771 / 776
页数:6
相关论文
共 50 条
  • [31] ELUENT SELECTION FOR THE DETERMINATION OF CATIONS IN ION CHROMATOGRAPHY
    GJERDE, DT
    JOURNAL OF CHROMATOGRAPHY, 1988, 439 (01): : 49 - 61
  • [32] SIMULTANEOUS DETERMINATION OF ANIONS AND CATIONS BY ION CHROMATOGRAPHY
    NESTERENKO, PN
    TARASENKO, DA
    SHPIGUN, OA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (03) : 222 - 233
  • [33] Determination of Cesium on Nickel Hexacyanoferrate-Aluminum Oxide Modified Electrodes
    Delgado, Luis
    Carrero, Hermes
    Fernandez, Lenys
    ELECTROANALYSIS, 2009, 21 (24) : 2713 - 2717
  • [34] Electrocatalytic determination of oxalate ions on chemically modified electrodes
    Shaidarova, LG
    Zaripova, SA
    Tikhonova, LN
    Budnikov, GK
    Fitsev, IM
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2001, 74 (05) : 750 - 754
  • [35] Electrocatalytic Determination of Oxalate Ions on Chemically Modified Electrodes
    L. G. Shaidarova
    S. A. Zaripova
    L. N. Tikhonova
    G. K. Budnikov
    I. M. Fitsev
    Russian Journal of Applied Chemistry, 2001, 74 : 750 - 754
  • [36] CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW
    BALDWIN, RP
    THOMSEN, KN
    TALANTA, 1991, 38 (01) : 1 - 16
  • [37] GAS-CHROMATOGRAPHY ON METHACRYLATE POLYMERS MODIFIED BY COBALT CATIONS
    PLATONOVA, NP
    ULOGOV, VO
    GRADIL, I
    SHVETS, F
    ZHURNAL FIZICHESKOI KHIMII, 1992, 66 (04): : 1043 - 1048
  • [38] POLYPYRROLE DODECYL-SULFATE ELECTRODE AS A MICROSENSOR FOR ELECTROINACTIVE CATIONS IN FLOW-INJECTION ANALYSIS AND ION CHROMATOGRAPHY
    MARTINEZ, RC
    DOMINGUEZ, FB
    GONZALEZ, FM
    MENDEZ, JH
    ORELLANA, RC
    ANALYTICA CHIMICA ACTA, 1993, 279 (02) : 299 - 307
  • [39] Electrochemical preparation, characterization and application of electrodes modified with nickel-cobalt hexacyanoferrate/graphene oxide-carbon nanotubes
    Deng, Keqin
    Li, Chunxiang
    Qiu, Xiyang
    Zhou, Jianhong
    Hou, Zhaohui
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 755 : 197 - 202
  • [40] APPLICATION OF CHEMICALLY MODIFIED ELECTRODES TO ORGANIC VOLTAMMETRIC ANALYSIS
    BALDWIN, RP
    PRICE, JF
    SIRIA, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 18 - 18