Osseointegration of metallic devices: Current trends based on implant hardware design

被引:117
作者
Coelho, Paulo G. [1 ,2 ]
Jimbo, Ryo [3 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet & Periodontol & Implantol, New York, NY USA
[2] NYU Abu Dhabi, Div Engn, Abu Dhabi, U Arab Emirates
[3] Malmo Univ, Fac Odontol, Dept Prosthodont, Malmo, Sweden
关键词
Bone; Osseointegration; Metallic devices; Design; ROOT FORM IMPLANTS; BONE-FORMATION ADJACENT; HUMAN DENTAL IMPLANTS; HISTOMORPHOMETRIC EVALUATION; PRIMARY STABILITY; DRILL SPEED; IN-VIVO; BIOMECHANICAL STABILITY; MECHANICAL-PROPERTIES; ENDOSSEOUS IMPLANTS;
D O I
10.1016/j.abb.2014.06.033
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Osseointegration of metallic devices has been one of the most successful treatments in rehabilitative dentistry and medicine over the past five decades. While highly successful, the quest for designing surgical instrumentation and associated implantable devices that hastens osseointegration has been perpetual and has often been approached as single variable preclinical investigations. The present manuscript presents how the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration, but may also be key in how efficient smaller length scale designing (at the micrometer and nanometer scale levels) may be in hastening early stages of osseointegration. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 99 条
[1]   Effect of drill speed on bone temperature [J].
Abouzgia, MB ;
Symington, JM .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 25 (05) :394-399
[2]   Early bone formation adjacent to rough and turned endosseous implant surfaces - An experimental study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Linder, E ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :381-392
[3]   Implant stability in relation to osseointegration: an experimental study in the Labrador dog [J].
Abrahamsson, Ingemar ;
Linder, Elena ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) :313-318
[4]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[5]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[6]  
Albrektsson T, 2004, INT J PROSTHODONT, V17, P544
[7]   Osteoinduction, osteoconduction and osseointegration [J].
Albrektsson, T ;
Johansson, C .
EUROPEAN SPINE JOURNAL, 2001, 10 (Suppl 2) :S96-S101
[8]   Thermal osteonecrosis and bone drilling parameters revisited [J].
Augustin, Goran ;
Davila, Slavko ;
Mihoci, Kristijan ;
Udiljak, Toma ;
Vedrina, Denis Stjepan ;
Antabak, Anko .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (01) :71-77
[9]   Mechanical properties of human bone surrounding plateau root form implants retrieved after 0.3-24 years of function [J].
Baldassarri, Marta ;
Bonfante, Estevam A. ;
Suzuki, Marcelo ;
Marin, Charles ;
Granato, Rodrigo ;
Tovar, Nick ;
Coelho, Paulo G. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (07) :2015-2021
[10]   Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704