Dual-purpose corneal tissue for anterior lamellar keratoplasty and Descemet's membrane endothelial keratoplasty

被引:5
|
作者
Menant-Tay, C. Larena [1 ,2 ]
Conlon, Ronan [1 ,2 ]
Teja, Salina [3 ]
Yeung, Season [1 ,2 ]
Teichman, Joshua [1 ,2 ]
Ziai, Setareh [1 ,2 ]
Baig, Kashif [1 ,2 ]
机构
[1] Ottawa Hosp, Vis Res Ctr, Res Inst, Regenerat Med Program, Ottawa, ON, Canada
[2] Univ Ottawa, Fac Med, Dept Ophthalmol, Ottawa, ON, Canada
[3] Univ British Columbia, Fac Med, Dept Ophthalmol, Vancouver, BC, Canada
来源
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE | 2016年 / 51卷 / 06期
关键词
PENETRATING KERATOPLASTY; TRANSPLANTATION; OPHTHALMOLOGY;
D O I
10.1016/j.jcjo.2016.05.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To assess the intraoperative issues and surgical outcomes of preparing a single-donor corneal tissue for same-day use in both deep anterior lamellar keratoplasty (DALK) and Descemet's membrane endothelial keratoplasty (DMEK). Design: Consecutive retrospective case series. Participants: Ten eyes of 10 patients who underwent DALK (5 patients) or DMEK (5 patients) surgery using dual-purpose corneal tissue. Methods: Five dual-purpose corneoscleral rims were used to prepare tissue for 5 DMEK and 5 DALK procedures. The submerged cornea using backgrounds away technique was first used to harvest the 5 DMEK grafts, and the remaining tissue was used for the 5 DALK grafts. Tissue preparation and operative use occurred on the same day. Tissue preparation challenges, intraoperative complications, and visual recovery were assessed. Results: There were no difficulties in preparing the 5 dual-purpose tissues, and all 10 lamellar transplants were completed successfully. At the 6-month follow-up, the mean best-corrected distance visual acuity improved from 20/250 to 20/80 in the DALK patients, and from 20/300 to 20/25 in the DMEK patients. Postoperative complications after DALK included retained viscoelastic agent at the interface in 1 patient and a double anterior chamber managed with rebubbling in another. After DMEK, a peripheral partial graft detachment occurred in 1 patient and was managed successfully with rebubbling. All corneas demonstrated clarity on slit-lamp examination. Conclusions: Single-donor corneal tissue can be effectively used for both DALK and DMEK, and may represent a more efficient use of corneal tissue. Complications with the preparation of dual-purpose tissue were not encountered.
引用
收藏
页码:408 / 411
页数:4
相关论文
共 50 条
  • [1] Simultaneous Deep Anterior Lamellar Keratoplasty and Descemet Membrane Endothelial Keratoplasty for Corneal Endothelial Failure With Stromal Scarring
    Kara, Necip
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (08): : 371 - 373
  • [2] Visual outcome of penetrating keratoplasty, deep anterior lamellar keratoplasty and Descemet membrane endothelial keratoplasty
    Garrido, Claudia
    Cardona, Genis
    Guell, Josep L.
    Pujol, Jaume
    JOURNAL OF OPTOMETRY, 2018, 11 (03) : 174 - 181
  • [3] Descemet Membrane Endothelial Keratoplasty for Failed Deep Anterior Lamellar Keratoplasty: A Case Series
    Einan-Lifshitz, Adi
    Sorkin, Nir
    Boutin, Tanguy
    Mednick, Zale
    Kreimei, Mohammad
    Chan, Clara C.
    Rootman, David S.
    CORNEA, 2018, 37 (06) : 682 - 686
  • [4] Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty
    Tausif, Hassan N.
    Johnson, Lauren
    Titus, Michael
    Mavin, Kyle
    Chandrasekaran, Navasuja
    Woodward, Maria A.
    Shtein, Roni M.
    Mian, Shahzad I.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (91):
  • [5] Endothelial keratoplasty: is Descemet membrane endothelial keratoplasty the Holy Grail of lamellar surgery? No
    M Tsatsos
    V S Liarakos
    C MacGregor
    I Athanasiadis
    E T Detorakis
    M M Moschos
    P Hossain
    D F Anderson
    Eye, 2017, 31 : 1333 - 1336
  • [6] Endothelial keratoplasty: is Descemet membrane endothelial keratoplasty the Holy Grail of lamellar surgery? No
    Tsatsos, M.
    Liarakos, V. S.
    MacGregor, C.
    Athanasiadis, I.
    Detorakis, E. T.
    Moschos, M. M.
    Hossain, P.
    Anderson, D. F.
    EYE, 2017, 31 (09) : 1333 - 1336
  • [7] Deep lamellar keratoplasty - Surgical techniques for anterior lamellar keratoplasty with and without baring of Descemet's membrane
    Anwar, M
    Teichmann, KD
    CORNEA, 2002, 21 (04) : 374 - 383
  • [8] A Comparison of the Corneal Thickness Following Descemet's Stripping Automated Endothelial Keratoplasty and Descemet's Membrane Endothelial Keratoplasty
    Sunouchi, Chihiro
    Hayashi, Takahiko
    Shimizu, Toshiki
    Hara, Yusuke
    Kurita, Junki
    Kobashigawa, Hiroko
    Oyakawa, Itaru
    Ida, Yasutsugu
    Kobayashi, Akira
    Shoji, Jun
    Yamagami, Satoru
    CURRENT EYE RESEARCH, 2023, 48 (08) : 712 - 718
  • [9] Deep Anterior Lamellar Keratoplasty After Descemet Stripping Automated Endothelial Keratoplasty
    Busin, Massimo
    Beltz, Jacqueline
    CORNEA, 2011, 30 (09) : 1048 - 1050
  • [10] Deep Anterior Lamellar Keratoplasty After Descemet Stripping Automated Endothelial Keratoplasty
    Gutfreund, Shay
    Leon, Pia
    Graffi, Shmuel
    Busin, Massimo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 175 : 129 - 136