Fundamental limits of scintillation detector timing precision

被引:68
作者
Derenzo, Stephen E. [1 ]
Choong, Woon-Seng [1 ]
Moses, William W. [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Div Life Sci, Berkeley, CA 94720 USA
关键词
scintillator; timing precision; timing resolution; Monte Carlo; photodetector; scintillation detector; TIME-RESOLUTION; DEPTH;
D O I
10.1088/0031-9155/59/13/3261
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we review the primary factors that affect the timing precision of a scintillation detector. Monte Carlo calculations were performed to explore the dependence of the timing precision on the number of photoelectrons, the scintillator decay and rise times, the depth of interaction uncertainty, the time dispersion of the optical photons (modeled as an exponential decay), the photodetector rise time and transit time jitter, the leading-edge trigger level, and electronic noise. The Monte Carlo code was used to estimate the practical limits on the timing precision for an energy deposition of 511 keV in 3 mm x 3 mm x 30 mm Lu2SiO5:Ce and LaBr3:Ce crystals. The calculated timing precisions are consistent with the best experimental literature values. We then calculated the timing precision for 820 cases that sampled scintillator rise times from 0 to 1.0 ns, photon dispersion times from 0 to 0.2 ns, photodetector time jitters from 0 to 0.5 ns fwhm, and A from 10 to 10 000 photoelectrons per ns decay time. Since the timing precision R was found to depend on A(-1/2) more than any other factor, we tabulated the parameter B, where R = BA(-1/2). An empirical analytical formula was found that fit the tabulated values of B with an rms deviation of 2.2% of the value of B. The theoretical lower bound of the timing precision was calculated for the example of 0.5 ns rise time, 0.1 ns photon dispersion, and 0.2 ns fwhm photodetector time jitter. The lower bound was at most 15% lower than leading-edge timing discrimination for A from 10 to 10 000 photoelectrons ns(-1). A timing precision of 8 ps fwhm should be possible for an energy deposition of 511 keV using currently available photodetectors if a theoretically possible scintillator were developed that could produce 10 000 photoelectrons ns(-1).
引用
收藏
页码:3261 / 3286
页数:26
相关论文
共 50 条
  • [41] Optimizing Timing Performance of Silicon Photomultiplier Based Scintillation Detectors
    Yeom, Jung-Yeol
    Vinke, Ruud
    Levin, Craig S.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3119 - 3121
  • [42] Performance characterization of a new high resolution PET scintillation detector
    Vandenbroucke, A.
    Foudray, A. M. K.
    Olcott, P. D.
    Levin, C. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (19) : 5895 - 5911
  • [43] Sensitivity of GAGG based scintillation neutron detector with SiPM readout
    Fedorov, A.
    Gurinovich, V
    Guzov, V
    Dosovitskiy, G.
    Korzhik, M.
    Kozhemyakin, V
    Lopatik, A.
    Kozlov, D.
    Mechinsky, V
    Retivov, V
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (10) : 2306 - 2312
  • [44] Radiopurity of a CeBr3 crystal used as scintillation detector
    Lutter, Guillaume
    Hult, Mikael
    Billnert, Robert
    Oberstedt, Andreas
    Oberstedt, Stephan
    Andreotti, Erica
    Marissens, Gerd
    Rosengard, Ulf
    Tzika, Faidra
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 703 : 158 - 162
  • [45] Development of a small scintillation detector with an optical fiber for fast neutrons
    Yagi, T.
    Unesaki, H.
    Misawa, T.
    Pyeon, C. H.
    Shiroya, S.
    Matsumoto, T.
    Harano, H.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (02) : 539 - 544
  • [46] Anticoincidence scintillation detector for the Signal experiment onboard the spacecraft Interhelioprobe
    Shustov, Alexander E.
    Ulin, Sergey E.
    Novikov, Alexander S.
    Dmitrenko, Valery V.
    Grachev, Viktor M.
    Chernysheva, Irina V.
    Uteshev, Ziyaetdin M.
    Vlasik, Konstantin F.
    Krivova, Kira V.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XX, 2018, 10762
  • [47] Benchmarking a novel inorganic scintillation detector for applications in radiation therapy
    Alharbi, Majed
    Martyn, Michael
    O'Keeffe, Sinead
    Therriault-Proulx, Francois
    Beaulieu, Luc
    Foley, Mark
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 124 - 131
  • [48] Scintillation SE detector for variable pressure scanning electron microscopes
    Jirak, J.
    Nedela, V.
    Cernoch, P.
    Cudek, P.
    Runstuk, J.
    JOURNAL OF MICROSCOPY, 2010, 239 (03) : 233 - 238
  • [49] New scintillation detector of backscattered electrons for the low voltage SEM
    Wandrol, Petr
    JOURNAL OF MICROSCOPY-OXFORD, 2007, 227 (01): : 24 - 29
  • [50] Study of scintillation detector fault diagnosis based on ELM method
    Ding, Tiansong
    Yan, Yongjun
    Li, Xiang
    Liu, Linfei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1032