Pulsed Laser Activated Cell Sorting with Three Dimensional Sheathless Inertial Focusing

被引:69
作者
Chen, Yue [1 ]
Chung, Aram J. [2 ]
Wu, Ting-Hsiang [1 ,3 ]
Teitell, Michael A. [4 ,5 ,6 ,7 ]
Di Carlo, Dino [7 ,8 ]
Chiou, Pei-Yu [1 ,7 ,8 ]
机构
[1] Univ Calif Los Angeles, Dept Mech & Aerosp Engn, Los Angeles, CA 90095 USA
[2] Rensselaer Polytech Inst, Dept Mech Aerosp & Nucl Engn, Troy, NY 12180 USA
[3] Univ Calif Los Angeles, Dept Pathol & Lab Med, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Inst Mol Biol, Jonsson Comprehens Canc Ctr, Dept Pathol & Lab Med,Broad Stem Cell Res Ctr, Los Angeles, CA 90095 USA
[5] Univ Calif Los Angeles, Inst Mol Biol, Jonsson Comprehens Canc Ctr, Dept Pediat,Broad Stem Cell Res Ctr, Los Angeles, CA 90095 USA
[6] Univ Calif Los Angeles, Inst Mol Biol, Jonsson Comprehens Canc Ctr, Dept Bioengn,Broad Stem Cell Res Ctr, Los Angeles, CA 90095 USA
[7] Univ Calif Los Angeles, Calif NanoSyst Inst, Los Angeles, CA 90095 USA
[8] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
关键词
cell sorting; inertial focusing; lab-on-a-chip devices; lasers; microfluidics; TOTAL ANALYSIS SYSTEMS; MICROFLUIDIC CHANNEL; MAMMALIAN-CELLS; MICROPARTICLES; SEPARATION;
D O I
10.1002/smll.201302885
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A pulsed laser activated cell sorter (PLACS) integrated with 3D sheathless inertial focusing sorts cells with high purity at high-throughput using a single layer PDMS channel that can be easily fabricated at low cost. Sort purity of >90% is achieved at a throughput of 10 000 particles s-1 without severe dilution effects from high volume sheath flows. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
引用
收藏
页码:1746 / 1751
页数:6
相关论文
共 48 条
[1]   The good, the bad, and the tiny: a review of microflow cytometry [J].
Ateya, Daniel A. ;
Erickson, Jeffrey S. ;
Howell, Peter B., Jr. ;
Hilliard, Lisa R. ;
Golden, Joel P. ;
Ligler, Frances S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1485-1498
[2]   Microfluidic: An innovative tool for efficient cell sorting [J].
Autebert, Julien ;
Coudert, Benoit ;
Bidard, Francois-Clement ;
Pierga, Jean-Yves ;
Descroix, Stephanie ;
Malaquin, Laurent ;
Viovy, Jean-Louis .
METHODS, 2012, 57 (03) :297-307
[3]   Microfluidics for cell separation [J].
Bhagat, Ali Asgar S. ;
Bow, Hansen ;
Hou, Han Wei ;
Tan, Swee Jin ;
Han, Jongyoon ;
Lim, Chwee Teck .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (10) :999-1014
[4]   Droplet sorting based on the number of encapsulated particles using a solenoid valve [J].
Cao, Zhenning ;
Chen, Fangyuan ;
Bao, Ning ;
He, Huacheng ;
Xu, Peisheng ;
Jana, Saikat ;
Jung, Sunghwan ;
Lian, Hongzhen ;
Lu, Chang .
LAB ON A CHIP, 2013, 13 (01) :171-178
[5]   3D pulsed laser-triggered high-speed microfluidic fluorescence-activated cell sorter [J].
Chen, Yue ;
Wu, Ting-Hsiang ;
Kung, Yu-Chun ;
Teitell, Michael A. ;
Chiou, Pei-Yu .
ANALYST, 2013, 138 (24) :7308-7315
[6]   An integrated dielectrophoretic chip for continuous bioparticle filtering, focusing, sorting, trapping, and detecting [J].
Cheng, I-Fang ;
Chang, Hsien-Chang ;
Hou, Diana ;
Chang, Hsueh-Chia .
BIOMICROFLUIDICS, 2007, 1 (02)
[7]   Human mammalian cell sorting using a highly integrated micro-fabricated fluorescence-activated cell sorter (μFACS) [J].
Cho, Sung Hwan ;
Chen, Chun H. ;
Tsai, Frank S. ;
Godin, Jessica M. ;
Lo, Yu-Hwa .
LAB ON A CHIP, 2010, 10 (12) :1567-1573
[8]   Sheathless focusing of microbeads and blood cells based on hydrophoresis [J].
Choi, Sungyoung ;
Song, Seungjeong ;
Choi, Chulhee ;
Park, Je-Kyun .
SMALL, 2008, 4 (05) :634-641
[9]   Microstructure-induced helical vortices allow single-stream and long-term inertial focusing [J].
Chung, Aram J. ;
Pulido, Dianne ;
Oka, Justin C. ;
Amini, Hamed ;
Masaeli, Mahdokht ;
Di Carlo, Dino .
LAB ON A CHIP, 2013, 13 (15) :2942-2949
[10]   Three Dimensional, Sheathless, and High-Throughput Microparticle Inertial Focusing Through Geometry-Induced Secondary Flows [J].
Chung, Aram J. ;
Gossett, Daniel R. ;
Di Carlo, Dino .
SMALL, 2013, 9 (05) :685-690