Dosimetric issues with simplified homogeneous body models in low frequency magnetic field exposure assessment

被引:4
|
作者
Schmid, Gernot [1 ,2 ]
Hirtl, Rene [1 ]
Samaras, Theodoros [2 ]
机构
[1] Seibersdorf Labs, Dept EMC & Opt, A-2444 Seibersdorf, Austria
[2] Aristotle Univ Thessaloniki, Dept Phys, GR-54124 Thessaloniki, Greece
关键词
magnetic field; dosimetry; disc model; body model; welding; IEC; 6282287.50; cm;
D O I
10.1088/1361-6498/ab25be
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simplified procedure, using circular disk models with homogeneous electric conductivity as representations for different body parts, has been proposed recently by product standard IEC 62822-3 for the assessment of magnetic field exposure in proximity to current-carrying conductors of welding equipment. Based on such simplified models, worst case coupling coefficients CCEi(I), i.e. maximum induced electric field strength, normalised for current and frequency, for body parts at different distances d to straight single and double wire arrangements, as well as rectangular loop-shaped current paths are tabulated in the standard. In this work we compared CCEi(I) values obtained by numerical computations with detailed anatomical models of the hand/forearm with the corresponding values given in IEC 62822-3 for current-carrying single wire conductors along the forearm at distances d. = 30, 50 and 100 mm, respectively. Our results clearly indicated that the CCEi(I) given in the standard may substantially underestimate the actual exposure. Using average values for tissue conductivities the observed extent of underestimation was up to 8.9 dB (factor 2.79) and may be even higher for worst case combinations of tissue conductivities. The reasons for this substantial underestimation are the oversimplified geometry, i.e. the circular disk does not reflect anatomical constrictions of the induction area present in realistic hand/forearm geometries, as well as the missing conductivity contrast between different tissues in the homogeneous disk models. Results of exposure assessment and corresponding minimum distances to components of welding equipment obtained by the simplified disk model approach suggested by IEC 62822-3 should therefore be considered with caution.
引用
收藏
页码:794 / 808
页数:15
相关论文
共 50 条
  • [41] Assessment of magnetic fluid stability in non-homogeneous magnetic field of a single-tooth magnetic fluid sealer
    Arefyev, I. M.
    Demidenko, O. V.
    Saikin, M. S.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2017, 431 : 20 - 23
  • [42] Effects of exposure to extremely low-frequency magnetic field of 2mT intensity on Spatial memory and learning in rat
    Morteza Kafaee
    Maryam Tehranipour
    Alireza Haghpeima
    Saeeedeh Ebrahimpour
    Annals of General Psychiatry, 9 (Suppl 1)
  • [43] Extremely Low Frequency Magnetic Field Exposure and Parkinson's Disease-A Systematic Review and Meta-Analysis of the Data
    Huss, Anke
    Koeman, Tom
    Kromhout, Hans
    Vermeulen, Roel
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2015, 12 (07): : 7348 - 7356
  • [44] Extremely Low Frequency Electric and Magnetic Fields Exposure: Survey of Recent Findings
    Bonato, Marta
    Chiaramello, Emma
    Parazzini, Marta
    Gajsek, Peter
    Ravazzani, Paolo
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2023, 3 (216-228): : 216 - 228
  • [45] Influence of alternating low frequency magnetic field on improvement of seed quality
    Rochalska, M.
    Grabowska-Topczewska, K.
    Mackiewicz, A.
    INTERNATIONAL AGROPHYSICS, 2011, 25 (03) : 265 - 269
  • [46] Effect of extremely low frequency magnetic field on enamel microhardness in rats
    Kargul, B.
    Yavuz, I.
    Akdag, M. Z.
    Durhan, A.
    EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY, 2011, 12 (04) : 253 - 255
  • [47] The effects of extremly low frequency magnetic field and mangan to the oral tissues
    Kaya, S.
    Celik, M. S.
    Akdag, M. Z.
    Adiguzel, O.
    Yavuz, I.
    Turnen, E. C.
    Ulku, S. Z.
    Ayaz, S. Ganidagli
    Ketani, A.
    Akpolat, V.
    Akkus, Z.
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2008, 22 (03) : 869 - 873
  • [48] Research on residual stress reduction by a low frequency alternating magnetic field
    Tang, F
    Lu, AL
    Mei, JF
    Fang, HZ
    Luo, XJ
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 1998, 74 (1-3) : 255 - 258
  • [49] Calibration of low frequency magnetic field meters using a Helmholtz coil
    de Melo, Celso Fabricio
    Araujo, Ricardo Luiz
    Ardjomand, Leonardo Morozowski
    Ramos Quoirin, Nilton S.
    Ikeda, Minoru
    Costa, Alexandre Albarello
    MEASUREMENT, 2009, 42 (09) : 1330 - 1334
  • [50] Extremely Low Frequency Magnetic Field Effects on Metabolite of Aspergillus Niger
    Gao, Mengxiang
    Zhang, Jialan
    Feng, Hao
    BIOELECTROMAGNETICS, 2011, 32 (01) : 73 - 78