Dosimetric issues with simplified homogeneous body models in low frequency magnetic field exposure assessment

被引:4
|
作者
Schmid, Gernot [1 ,2 ]
Hirtl, Rene [1 ]
Samaras, Theodoros [2 ]
机构
[1] Seibersdorf Labs, Dept EMC & Opt, A-2444 Seibersdorf, Austria
[2] Aristotle Univ Thessaloniki, Dept Phys, GR-54124 Thessaloniki, Greece
关键词
magnetic field; dosimetry; disc model; body model; welding; IEC; 6282287.50; cm;
D O I
10.1088/1361-6498/ab25be
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simplified procedure, using circular disk models with homogeneous electric conductivity as representations for different body parts, has been proposed recently by product standard IEC 62822-3 for the assessment of magnetic field exposure in proximity to current-carrying conductors of welding equipment. Based on such simplified models, worst case coupling coefficients CCEi(I), i.e. maximum induced electric field strength, normalised for current and frequency, for body parts at different distances d to straight single and double wire arrangements, as well as rectangular loop-shaped current paths are tabulated in the standard. In this work we compared CCEi(I) values obtained by numerical computations with detailed anatomical models of the hand/forearm with the corresponding values given in IEC 62822-3 for current-carrying single wire conductors along the forearm at distances d. = 30, 50 and 100 mm, respectively. Our results clearly indicated that the CCEi(I) given in the standard may substantially underestimate the actual exposure. Using average values for tissue conductivities the observed extent of underestimation was up to 8.9 dB (factor 2.79) and may be even higher for worst case combinations of tissue conductivities. The reasons for this substantial underestimation are the oversimplified geometry, i.e. the circular disk does not reflect anatomical constrictions of the induction area present in realistic hand/forearm geometries, as well as the missing conductivity contrast between different tissues in the homogeneous disk models. Results of exposure assessment and corresponding minimum distances to components of welding equipment obtained by the simplified disk model approach suggested by IEC 62822-3 should therefore be considered with caution.
引用
收藏
页码:794 / 808
页数:15
相关论文
共 50 条
  • [21] Models of performances of dosimetric telescopes in the anisotropic radiation field in low earth orbit
    Hirn, Attila
    ACTA ASTRONAUTICA, 2010, 66 (9-10) : 1368 - 1372
  • [22] A Simplified Procedure for the Exposure to the Magnetic Field Produced by Resistance Spot Welding Guns
    Canova, Aldo
    Freschi, Fabio
    Giaccone, Luca
    Manca, Michele
    IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (03)
  • [23] Magnetic field and dosimetric study at intermediate frequency range using the coil source model
    Nishizawa, S
    Landstorfer, F
    Matsumoto, K
    Hashimoto, O
    IEICE TRANSACTIONS ON ELECTRONICS, 2006, E89C (04) : 524 - 530
  • [24] EFFECT OF EXTREMELY LOW FREQUENCY MAGNETIC FIELD AND MOBILE PHONE EXPOSURE ON NASAL MUCOSA AND NOSE SKIN
    Dasdag, Suleyman
    Akdag, Mehmet Zulkuf
    Meric, Faruk
    Uzunlar, Ali Kemal
    Celik, Mustafa Salih
    Gun, Ramazan
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2011, 25 (01) : 2273 - 2278
  • [25] Effect of extremely low frequency magnetic field and mobile phone exposure on nasal mucosa and nose skin
    Dasdag S.
    Akdag M.Z.
    Meric F.
    Uzunlar A.K.
    Celik M.S.
    Gun R.
    Biotechnology and Biotechnological Equipment, 2011, 25 (01) : 2273 - 2278
  • [26] Hydrothermal assessment of ferrofluids in a metal foam tube under low-frequency magnetic field
    Amani, Mohammad
    Ameri, Mohammad
    Kasaeian, Alibakhsh
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 127 : 242 - 251
  • [27] Calculation of the Interference Voltage at the Input of Cardiac Pacemakers in Low Frequency Magnetic Field: Influence of the Homogeneous and Heterogeneous Coupling Medium
    Andretzko, J. P.
    Hedjiedj, A.
    Guendouz, L.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1048 - 1051
  • [28] Low frequency magnetic field parameters acquisition and processing
    Urma, D
    Golovanov, C
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2005, 161 (1-2) : 334 - 337
  • [29] Effect of magnetic field at low frequency on cells arrangement
    Miyamoto, C
    Hashimoto, S
    Morita, Y
    Tsuji, H
    Yamanaka, A
    Sekiyama, T
    Sahara, T
    Yamasaki, K
    Yamanari, T
    Morioka, Y
    Wu, Y
    7TH WORLD MULTICONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL VIII, PROCEEDINGS, 2003, : 62 - 66
  • [30] IMPACT OF LOW FREQUENCY ELECTROMAGNETIC FIELD EXPOSURE ON THE CANDIDA ALBICANS
    Malikova, Ivona
    Janousek, Ladislav
    Fantova, Vladyslava
    Jira, Jaroslav
    Kriha, Vitezslav
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2015, 66 (02): : 108 - 112