Dosimetric issues with simplified homogeneous body models in low frequency magnetic field exposure assessment

被引:4
|
作者
Schmid, Gernot [1 ,2 ]
Hirtl, Rene [1 ]
Samaras, Theodoros [2 ]
机构
[1] Seibersdorf Labs, Dept EMC & Opt, A-2444 Seibersdorf, Austria
[2] Aristotle Univ Thessaloniki, Dept Phys, GR-54124 Thessaloniki, Greece
关键词
magnetic field; dosimetry; disc model; body model; welding; IEC; 6282287.50; cm;
D O I
10.1088/1361-6498/ab25be
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simplified procedure, using circular disk models with homogeneous electric conductivity as representations for different body parts, has been proposed recently by product standard IEC 62822-3 for the assessment of magnetic field exposure in proximity to current-carrying conductors of welding equipment. Based on such simplified models, worst case coupling coefficients CCEi(I), i.e. maximum induced electric field strength, normalised for current and frequency, for body parts at different distances d to straight single and double wire arrangements, as well as rectangular loop-shaped current paths are tabulated in the standard. In this work we compared CCEi(I) values obtained by numerical computations with detailed anatomical models of the hand/forearm with the corresponding values given in IEC 62822-3 for current-carrying single wire conductors along the forearm at distances d. = 30, 50 and 100 mm, respectively. Our results clearly indicated that the CCEi(I) given in the standard may substantially underestimate the actual exposure. Using average values for tissue conductivities the observed extent of underestimation was up to 8.9 dB (factor 2.79) and may be even higher for worst case combinations of tissue conductivities. The reasons for this substantial underestimation are the oversimplified geometry, i.e. the circular disk does not reflect anatomical constrictions of the induction area present in realistic hand/forearm geometries, as well as the missing conductivity contrast between different tissues in the homogeneous disk models. Results of exposure assessment and corresponding minimum distances to components of welding equipment obtained by the simplified disk model approach suggested by IEC 62822-3 should therefore be considered with caution.
引用
收藏
页码:794 / 808
页数:15
相关论文
共 50 条
  • [1] Simulation of Human Body Exposure to High and Low Frequency Wireless Power Transfer Systems using Simplified Models
    Rasic, Petra
    Skiljo, Maja
    Blazevic, Zoran
    Doric, Vicko
    Poljak, Dragan
    2018 3RD INTERNATIONAL CONFERENCE ON SMART AND SUSTAINABLE TECHNOLOGIES (SPLITECH), 2018, : 375 - 380
  • [2] Equivalent magnetic vector potential model for low-frequency magnetic exposure assessment
    Diao, Y. L.
    Sun, W. N.
    He, Y. Q.
    Leung, S. W.
    Siu, Y. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (19) : 7905 - 7922
  • [3] Simplified pregnant woman models for the fetus exposure assessment
    Jala, Marjorie
    Conil, Emmanuelle
    Varsier, Nadege
    Wiart, Joe
    Hadjem, Abdelhamid
    Moulines, Eric
    Levy-Leduc, Celine
    COMPTES RENDUS PHYSIQUE, 2013, 14 (05) : 412 - 417
  • [4] Dosimetric assessment of simultaneous exposure to ELF electric and magnetic fields
    Leitgeb, Norbert
    Cech, Roman
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) : 671 - 674
  • [5] Frequency dependence of the effective magnetic permeability of plates in homogeneous magnetic field
    Sandovskii, VA
    Dyakin, VV
    Dudarev, MS
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2001, 37 (11) : 757 - 767
  • [6] Effect of extremely low frequency magnetic field exposure on DNA transposition in relation to frequency, wave shape and exposure time
    Giorgi, Gianfranco
    Marcantonio, Pamela
    Bersani, Ferdinando
    Gavoci, Entele
    Del Re, Brunella
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2011, 87 (06) : 601 - 608
  • [7] Frequency Dependence of the Effective Magnetic Permeability of Plates in Homogeneous Magnetic Field
    V. A. Sandovskii
    V. V. Dyakin
    M. S. Dudarev
    Russian Journal of Nondestructive Testing, 2001, 37 : 757 - 767
  • [9] Prenatal exposure to extremely low frequency magnetic field and its impact on fetal growth
    Yanfeng Ren
    Jianping Chen
    Maohua Miao
    De-Kun Li
    Hong Liang
    Ziliang Wang
    Fen Yang
    Xiaowei Sun
    Wei Yuan
    Environmental Health, 18
  • [10] Prenatal exposure to extremely low frequency magnetic field and its impact on fetal growth
    Ren, Yanfeng
    Chen, Jianping
    Miao, Maohua
    Li, De-Kun
    Liang, Hong
    Wang, Ziliang
    Yang, Fen
    Sun, Xiaowei
    Yuan, Wei
    ENVIRONMENTAL HEALTH, 2019, 18 (1)