Role of C-Arm VasoCT in the Use of Endovascular WEB Flow Disruption in Intracranial Aneurysm Treatment

被引:48
作者
Caroff, J. [1 ]
Mihalea, C. [1 ]
Neki, H. [1 ]
Ruijters, D. [2 ]
Ikka, L. [1 ]
Benachour, N. [1 ]
Moret, J. [1 ]
Spelle, L. [1 ]
机构
[1] Beaujon Med Ctr, Dept Intervent Neuroradiol, F-92110 Clichy, France
[2] Philips Healthcare, Intervent Xray Innovat, Best, Netherlands
关键词
EMBOLIZATION; DEVICE;
D O I
10.3174/ajnr.A3860
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The WEB aneurysm embolization system is still under evaluation but seems to be a promising technique to treat wide-neck bifurcation aneurysms. However, this device is barely visible using conventional DSA; thus, high-resolution contrast-enhanced flat panel detector CT (VasoCT) may be useful before detachment to assess the sizing and positioning of the WEB. The purpose of this study was to evaluate the interest of VasoCT during WEB procedures. MATERIALS AND METHODS: From March 2012 to July 2013, twelve patients (10 women and 2 men; age range, 44-55 years) were treated for 13 intracranial aneurysms with the WEB device. DSA and VasoCT were used and compared to depict any protrusion of the device in parent arteries before detachment. Two neuroradiologists reviewed each VasoCT scan, and the quality was graded on a subjective quality scale. RESULTS: The mesh of the WEB was very well-depicted in all cases, allowing a very good assessment of its deployment. Device protrusion was clearly detected with VasoCT in 5 cases, leading to WEB repositioning or size substitution. During follow-up, VasoCT also allows good assessment of eventual residual blood flow inside the aneurysm or the WEB device. CONCLUSIONS: Unlike DSA, VasoCT is an excellent tool to assess WEB deployment and positioning. In our experience, it allowed a precise evaluation of the WEB sizing and its relation to the parent vessel. Such information very likely enhances the ability to safely use this device, avoiding potential thromboembolic events in cases of protrusion in the parent arteries.
引用
收藏
页码:1353 / 1357
页数:5
相关论文
共 13 条
[1]  
Benndorf G, 2005, AM J NEURORADIOL, V26, P1813
[2]   The Woven EndoBridge: A New Aneurysm Occlusion Device [J].
Ding, Y. H. ;
Lewis, D. A. ;
Kadirvel, R. ;
Dai, D. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (03) :607-611
[3]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[4]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[5]   The Woven EndoBridge Cerebral Aneurysm Embolization Device (WEB II): initial clinical experience [J].
Klisch, Joachim ;
Sychra, Vojtech ;
Strasilla, Christoph ;
Liebig, Thomas ;
Fiorella, David .
NEURORADIOLOGY, 2011, 53 (08) :599-607
[6]   WEB Device for Endovascular Treatment of Wide-Neck Bifurcation Aneurysms [J].
Lubicz, B. ;
Mine, B. ;
Collignon, L. ;
Brisbois, D. ;
Duckwiler, G. ;
Strother, C. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (06) :1209-1214
[7]   Contrast-Enhanced Angiographic Cone-Beam CT of Cerebrovascular Stents: Experimental Optimization and Clinical Application [J].
Patel, N. V. ;
Gounis, M. J. ;
Wakhloo, A. K. ;
Noordhoek, N. ;
Blijd, J. ;
Babic, D. ;
Takhtani, D. ;
Lee, S. -K. ;
Norbash, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :137-144
[8]   Intrasaccular Flow-Disruption Treatment of Intracranial Aneurysms: Preliminary Results of a Multicenter Clinical Study [J].
Pierot, L. ;
Liebig, T. ;
Sychra, V. ;
Kadziolka, K. ;
Dorn, F. ;
Strasilla, C. ;
Kabbasch, C. ;
Klisch, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (07) :1232-1238
[9]   Endovascular WEB Flow Disruption in Middle Cerebral Artery Aneurysms: Preliminary Feasibility, Clinical, and Anatomical Results in a Multicenter Study [J].
Pierot, Laurent ;
Klisch, Joachim ;
Cognard, Christophe ;
Szikora, Istvan ;
Mine, Benjamin ;
Kadziolka, Krzysztof ;
Sychra, Vojtech ;
Gubucz, Istvan ;
Januel, Anne-Christine ;
Lubicz, Boris .
NEUROSURGERY, 2013, 73 (01) :27-34
[10]   Flat panel detector angiopaphic CT for Stent-Assisted coil embolization of broad-based cerebral aneurysms [J].
Richter, G. ;
Engelhorn, T. ;
Struffert, T. ;
Doelken, M. ;
Ganslandt, O. ;
Hornegger, J. ;
Kalender, W. A. ;
Doerfler, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (10) :1902-1908