Simulation of dosimetric consequences of 4D-CT-based motion margin estimation for proton radiotherapy using patient tumor motion data

被引:19
|
作者
Koybasi, Ozhan [1 ,2 ]
Mishra, Pankaj [2 ,3 ,4 ]
James, Sara St. [2 ,3 ,4 ]
Lewis, John H. [2 ,3 ,4 ]
Seco, Joao [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Brigham & Womens Hosp, Dept Radiat Oncol, Boston, MA 02115 USA
[4] Dana Farber Canc Inst, Boston, MA 02115 USA
关键词
four-dimensional computed tomography; internal target volume; lung tumor motion; XCAT phantom; proton radiotherapy; 4D XCAT PHANTOM; LUNG-CANCER; RESPIRATORY MOTION; TARGET VOLUME; THERAPY; TRACKING; PROJECTIONS; ALGORITHM; SIZE;
D O I
10.1088/0031-9155/59/4/853
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For the radiation treatment of lung cancer patients, four-dimensional computed tomography (4D-CT) is a common practice used clinically to image tumor motion and subsequently determine the internal target volume (ITV) from the maximum intensity projection (MIP) images. ITV, which is derived from short pre-treatment 4D-CT scan (<6 s per couch position), may not adequately cover the extent of tumor motion during the treatment, particularly for patients that exhibit a large respiratory variability. Inaccurate tumor localization may result in under-dosage of the tumor or over-dosage of the surrounding tissues. The purpose of this study is therefore to assess the degree of tumor under-dosage in case of regular and irregular breathing for proton radiotherapy using ITV-based treatment planning. We place a spherical lesion into a modified XCAT phantom that is also capable of producing 4D images based on irregular breathing, and move the tumor according to real tumor motion data, which is acquired over multiple days by tracking gold fiducial markers implanted into the lung tumors of patients. We derive ITVs by taking the union of all tumor positions during 6 s of tumor motion in the phantom using the first day patient tumor tracking data. This is equivalent to ITVs generated clinically from cine-mode 4D-CT MIP images. The treatment plans created for different ITVs are then implemented on dynamic phantoms with tumor motion governed by real tumor tracking data from consecutive days. By comparing gross tumor volume dose distribution on days of 'treatment' with the ITV dose distribution, we evaluate the deviation of the actually delivered dose from the predicted dose. Our results have shown that the proton treatment planning on ITV derived from pre-treatment cine-mode 4D-CT can result in under-dosage (dose covering 95% of volume) of the tumor by up to 25.7% over 3 min of treatment for the patient with irregular respiratory motion. Tumor under-dosage is less significant for the patient with relatively regular breathing. We have demonstrated that proton therapy using the pre-treatment 4D-CT based ITV method can lead to significant under-dosage of the tumor, highlighting the need for daily customization to generate a target volume that represents tumor positions during the treatment more accurately.
引用
收藏
页码:853 / 867
页数:15
相关论文
共 27 条
  • [21] Feasibility of using single photon counting X-ray for lung tumor position estimation based on 4D-CT
    Aschenbrenner, Katharina P.
    Guthier, Christian V.
    Lyatskaya, Yulia
    Boda-Heggemann, Judit
    Wenz, Frederik
    Hesser, Juergen W.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 243 - 254
  • [22] Detailed dosimetric evaluation of inter-fraction and respiratory motion in lung stereotactic body radiation therapy based on daily 4D cone beam CT images
    Huesa-Berral, Carlos
    Juan-Cruz, Celia
    van Kranen, Simon
    Rossi, Maddalena
    Belderbos, Jose
    Azcona, Juan Diego
    Burguete, Javier
    Sonke, Jan-Jakob
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (01)
  • [23] Evaluation of mesh- and binary-based contour propagation methods in 4D thoracic radiotherapy treatments using patient 4D CT images
    Ma, Yuanyuan
    Liu, Xinguo
    Dai, Zhongying
    He, Pengbo
    Yan, Yuanlin
    Shen, Guosheng
    Yuan, Ping
    Li, Qiang
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 36 : 46 - 53
  • [24] Learning-based simulation and modeling of unorganized chaining behavior using data generated from 3D human motion tracking
    Malviya, Abhinav
    Kala, Rahul
    ROBOTICA, 2022, 40 (03) : 544 - 569
  • [25] MR-MOTUS: model-based non-rigid motion estimation for MR-guided radiotherapy using a reference image and minimal k-space data
    Huttinga, Niek R. F.
    van den Berg, Cornelis A. T.
    Luijten, Peter R.
    Sbrizzi, Alessandro
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (01)
  • [26] Impact of a large breast separation on radiation dose delivery to the ipsilateral lung as result of respiratory motion quantified using free breathing and 4D CT-based planning in patients with locally advanced breast cancers: A potential for adverse clinical implications
    Heineman, Thomas E.
    Sabbas, Albert
    Delamerced, Marilynn Santos
    Chiu, Ya-lin
    Smith, Michael
    Parashar, Bhupesh
    Wernicke, A. Gabriella
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2013, 9 (01) : 154 - 160
  • [27] Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT)
    den Otter, Lydia A.
    Chen, Kuanling
    Janssens, Guillaume
    Meijers, Arturs
    Both, Stefan
    Langendijk, Johannes A.
    Rosen, Lane R.
    Wu, Hsinshun T.
    Knopf, Antje-Christin
    MEDICAL PHYSICS, 2020, 47 (12) : 6381 - 6387