Simulation of dosimetric consequences of 4D-CT-based motion margin estimation for proton radiotherapy using patient tumor motion data

被引:19
|
作者
Koybasi, Ozhan [1 ,2 ]
Mishra, Pankaj [2 ,3 ,4 ]
James, Sara St. [2 ,3 ,4 ]
Lewis, John H. [2 ,3 ,4 ]
Seco, Joao [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Brigham & Womens Hosp, Dept Radiat Oncol, Boston, MA 02115 USA
[4] Dana Farber Canc Inst, Boston, MA 02115 USA
关键词
four-dimensional computed tomography; internal target volume; lung tumor motion; XCAT phantom; proton radiotherapy; 4D XCAT PHANTOM; LUNG-CANCER; RESPIRATORY MOTION; TARGET VOLUME; THERAPY; TRACKING; PROJECTIONS; ALGORITHM; SIZE;
D O I
10.1088/0031-9155/59/4/853
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For the radiation treatment of lung cancer patients, four-dimensional computed tomography (4D-CT) is a common practice used clinically to image tumor motion and subsequently determine the internal target volume (ITV) from the maximum intensity projection (MIP) images. ITV, which is derived from short pre-treatment 4D-CT scan (<6 s per couch position), may not adequately cover the extent of tumor motion during the treatment, particularly for patients that exhibit a large respiratory variability. Inaccurate tumor localization may result in under-dosage of the tumor or over-dosage of the surrounding tissues. The purpose of this study is therefore to assess the degree of tumor under-dosage in case of regular and irregular breathing for proton radiotherapy using ITV-based treatment planning. We place a spherical lesion into a modified XCAT phantom that is also capable of producing 4D images based on irregular breathing, and move the tumor according to real tumor motion data, which is acquired over multiple days by tracking gold fiducial markers implanted into the lung tumors of patients. We derive ITVs by taking the union of all tumor positions during 6 s of tumor motion in the phantom using the first day patient tumor tracking data. This is equivalent to ITVs generated clinically from cine-mode 4D-CT MIP images. The treatment plans created for different ITVs are then implemented on dynamic phantoms with tumor motion governed by real tumor tracking data from consecutive days. By comparing gross tumor volume dose distribution on days of 'treatment' with the ITV dose distribution, we evaluate the deviation of the actually delivered dose from the predicted dose. Our results have shown that the proton treatment planning on ITV derived from pre-treatment cine-mode 4D-CT can result in under-dosage (dose covering 95% of volume) of the tumor by up to 25.7% over 3 min of treatment for the patient with irregular respiratory motion. Tumor under-dosage is less significant for the patient with relatively regular breathing. We have demonstrated that proton therapy using the pre-treatment 4D-CT based ITV method can lead to significant under-dosage of the tumor, highlighting the need for daily customization to generate a target volume that represents tumor positions during the treatment more accurately.
引用
收藏
页码:853 / 867
页数:15
相关论文
共 27 条
  • [1] Simultaneous segmentation and motion estimation in 4D-CT data using a variational approach
    Ehrhardt, Jan
    Schmidt-Richberg, Alexander
    Handels, Heinz
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [2] 3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models
    Dhou, S.
    Hurwitz, M.
    Mishra, P.
    Cai, W.
    Rottmann, J.
    Li, R.
    Williams, C.
    Wagar, M.
    Berbeco, R.
    Ionascu, D.
    Lewis, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09) : 3807 - 3824
  • [3] Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model
    Marx, Mirko
    Ehrhardt, Jan
    Werner, Rene
    Schlemmer, Heinz-Peter
    Handels, Heinz
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (03) : 401 - 409
  • [4] A feasibility study of intrafractional tumor motion estimation based on 4D-CBCT using diaphragm as surrogate
    Zhou, Dingyi
    Quan, Hong
    Yan, Di
    Chen, Shupeng
    Qin, An
    Stanhope, Carl
    Lachaine, Martin
    Liang, Jian
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 525 - 531
  • [5] Estimation of motion fields by non-linear registration for local lung motion analysis in 4D CT image data
    Werner, Rene
    Ehrhardt, Jan
    Schmidt-Richberg, Alexander
    Heiss, Anabell
    Handels, Heinz
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (06) : 595 - 605
  • [6] Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model
    Mirko Marx
    Jan Ehrhardt
    René Werner
    Heinz-Peter Schlemmer
    Heinz Handels
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 401 - 409
  • [7] A novel approach for estimating lung tumor motion based on dynamic features in 4D-CT
    Gong, Ye-Jun
    Li, Yue-Ke
    Zhou, Rongrong
    Liang, Zhan
    Zhang, Yingying
    Cheng, Tingting
    Zhang, Zi-Jian
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2024, 115
  • [8] Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT
    Weiss, Elisabeth
    Wijesooriya, Krishni
    Dill, S. Vaughn
    Keall, Paul J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (01): : 296 - 307
  • [9] Estimation of motion fields by non-linear registration for local lung motion analysis in 4D CT image data
    René Werner
    Jan Ehrhardt
    Alexander Schmidt-Richberg
    Anabell Heiß
    Heinz Handels
    International Journal of Computer Assisted Radiology and Surgery, 2010, 5 : 595 - 605
  • [10] Dose Accumulation based on Optimized Motion Field Estimation using Non-Linear Registration in Thoracic 4D CT Image Data
    Werner, R.
    Ehrhardt, J.
    Schmidt-Richberg, A.
    Bodmann, B.
    Cremers, F.
    Handels, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 950 - 953