The effect of overpotentials on the transient response of the 300 W SOFC cell stack voltage

被引:50
作者
Komatsu, Y. [1 ]
Brus, G. [2 ]
Kimijima, S. [3 ]
Szmyd, J. S. [2 ]
机构
[1] Shibaura Inst Technol, Grad Sch Engn, Div Reg Environm Syst, Minuma Ku, Saitama 3378570, Japan
[2] AGH Univ Sci & Technol, Fac Energy & Fuels, Dept Fundamental Res Energy Engn, PL-30059 Krakow, Poland
[3] Shibaura Inst Technol, Coll Syst Engn & Sci, Dept Machinery & Control Syst, Minuma Ku, Saitama 3378570, Japan
关键词
Solid oxide fuel cells; Cell stack; Transient characterization; Fuel utilization factor; Current-based fuel control; OXIDE FUEL-CELL; PERFORMANCE; FLOW;
D O I
10.1016/j.apenergy.2013.11.017
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the results of an experimental investigation of transient characterizations of 300 W planar type Solid Oxide Fuel Cell (SOFC) cell stack during load change. It indicates the transient characterization obtained during a ramped electric current with a Current-Based Fuel Control (CBFC) strategy. The fuel utilization factor is chosen for a reference of the CBFC strategy and is kept constant to the ramping electric current. The fuel utilization factor can be described as a ratio of consumed fuel (expressed as a function with an applied electric current) to supplied fuel. For the simplification of discussion, hydrogen was used as fuel by mixing it with nitrogen in order to satisfy the constant gas residential time in all cases and instances. The transient response of the cell voltage obtained under several thermal conditions was shown for discussion. The effect of overpotentials, associated with the cell's operating temperature, on the transient response of the cell voltage is primarily discussed. The paper indicates that reducing the fuel flow rate, namely, setting a higher set-point for the fuel utilization factor, may decrease the OCV, increase concentration polarization and finally degrade cell performance. This paper also pointed out the importance of operating temperature management on both improving the steady-state cell performance and eliminating the negative effect of the overpotentials that appear on the transient response of the cell voltage. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:352 / 359
页数:8
相关论文
共 20 条
[1]   Review on modeling development for multiscale chemical reactions coupled transport phenomena in solid oxide fuel cells [J].
Andersson, Martin ;
Yuan, Jinliang ;
Sunden, Bengt .
APPLIED ENERGY, 2010, 87 (05) :1461-1476
[2]   Incorporating available micro gas turbines and fuel cell: Matching considerations and performance evaluation [J].
Bakalis, Diamantis P. ;
Stamatis, Anastassios G. .
APPLIED ENERGY, 2013, 103 :607-617
[3]   Part load operation of a SOFC/GT hybrid system: Dynamic analysis [J].
Barelli, L. ;
Bidini, G. ;
Ottaviano, A. .
APPLIED ENERGY, 2013, 110 :173-189
[4]   Performance analysis of an integrated CHP system with thermal and Electric Energy Storage for residential application [J].
Bianchi, M. ;
De Pascale, A. ;
Melino, F. .
APPLIED ENERGY, 2013, 112 :928-938
[6]   A complete polarization model of a solid oxide fuel cell and its sensitivity to the change of cell component thickness [J].
Chan, SH ;
Khor, KA ;
Xia, ZT .
JOURNAL OF POWER SOURCES, 2001, 93 (1-2) :130-140
[7]   Numerical analysis of an internal methane reforming solid oxide fuel cell with fuel recycling [J].
Eveloy, Valerie .
APPLIED ENERGY, 2012, 93 :107-115
[8]   Cathode-anode side interaction in SOFC hybrid systems [J].
Ferrari, Mario L. ;
Massardo, Aristide F. .
APPLIED ENERGY, 2013, 105 :369-379
[9]   Efficiency analyses of ethanol-fueled solid oxide fuel cell power system [J].
Hong, Wen-Tang ;
Yen, Tzu-Hsiang ;
Chung, Tsang-Dong ;
Huang, Cheng-Nan ;
Chen, Bao-Dong .
APPLIED ENERGY, 2011, 88 (11) :3990-3998
[10]   Experimental study on the 300W class planar type solid oxide fuel cell stack: Investigation for appropriate fuel provision control and the transient capability of the cell performance [J].
Komatsu, Y. ;
Brus, G. ;
Kimijima, S. ;
Szmyd, J. S. .
6TH EUROPEAN THERMAL SCIENCES CONFERENCE (EUROTHERM 2012), 2012, 395