Determination of pectin degree of esterification by diffuse reflectance Fourier transform infrared spectroscopy

被引:573
|
作者
Gnanasambandam, R [1 ]
Proctor, A [1 ]
机构
[1] Univ Arkansas, Dept Food Sci, Fayetteville, AR 72704 USA
关键词
pectins; DE; FTIR;
D O I
10.1016/S0308-8146(99)00191-0
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A diffuse reflectance Fourier transform infrared spectroscopy (DRIFTS) method was developed to measure the degree of esterification (DE) of commercial pectin samples. The relationship between infrared spectroscopy data and titrimetrically determined DE values was investigated. The ester carbonyl band area (C=O) occurring at a mean frequency of 1756 cm(-1) had the highest correlation (R-2 = 0.822) with the mean DE of the bands observed. The DE values of pectin samples calculated from the line fit equation were comparable to those obtained from the titrimetric method. Mean DE values obtained were within 3.23% for DE 71.6, 2.9% for DE 62, and less than 1% for DE 55.3 of values obtained by titrimetric method. Spectral variations due to sample source have to be considered in developing prediction equations using FTIR. DRIFTS can be a rapid, alternative method to titrimetric analysis of pectin DE. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:327 / 332
页数:6
相关论文
共 50 条
  • [21] Rapid screening on aflatoxins' presence in Pistachia vera nuts using diffuse reflectance infrared Fourier transform spectroscopy and chemometrics
    Valasi, Lydia
    Georgiadou, Maria
    Tarantilis, Petros A.
    Yanniotis, Stavros
    Pappas, Christos S.
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2021, 58 (01): : 356 - 365
  • [22] Diffuse reflectance Fourier transform infrared spectroscopy for simultaneous quantification of total phenolics and condensed tannins contained in grape seeds
    Kyraleou, Maria
    Pappas, Christos
    Voskidi, Eleni
    Kotseridis, Yorgos
    Basalekou, Marianthi
    Tarantilis, Petros A.
    Kallithraka, Stamatina
    INDUSTRIAL CROPS AND PRODUCTS, 2015, 74 : 784 - 791
  • [23] DETERMINATION OF SILICON DIOXIDE COATED ON ALUMINUM-OXIDE POWDER BY DIFFUSE REFLECTANCE INFRARED FOURIER-TRANSFORM SPECTROMETRY
    TSUGE, A
    UWAMINO, Y
    SANDO, M
    TOWATA, A
    BUNSEKI KAGAKU, 1991, 40 (11) : 605 - 608
  • [24] Application of multibounce attenuated total reflectance Fourier transform infrared spectroscopy and chemometrics for determination of aspartame in soft drinks
    Khurana, Harpreet Kaur
    Cho, Il Kyu
    Shim, Jae Yong
    Li, Qing X.
    Jun, Soojin
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (03) : 778 - 783
  • [25] Quantitative determination of moisture in lubricants by Fourier transform infrared spectroscopy
    Van De Voort, FR
    Sedman, J
    Yaylayan, V
    Saint Laurent, C
    Mucciardi, C
    APPLIED SPECTROSCOPY, 2004, 58 (02) : 193 - 198
  • [26] STUDY ON THE STRUCTURE OF TIO2 THIN-FILM BY MEANS OF DIFFUSE REFLECTANCE INFRARED FOURIER-TRANSFORM SPECTROSCOPY
    WANG, SQ
    XU, WB
    LI, TK
    XU, LG
    SPECTROSCOPY LETTERS, 1993, 26 (05) : 863 - 872
  • [27] Quantitative determination of hydroperoxides by Fourier transform infrared spectroscopy with a disposable infrared card
    Ma, K
    van de Voort, FR
    Ismail, AA
    Sedman, J
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1998, 75 (09) : 1095 - 1101
  • [28] Quantitative Determination of Degree of Conversion in Photocured Poly(urethane-dimethacrylate)s by Fourier Transform Infrared Spectroscopy
    Barszczewska-Rybarek, Izabela M.
    JOURNAL OF APPLIED POLYMER SCIENCE, 2012, 123 (03) : 1604 - 1611
  • [29] POTENTIAL OF THE DIFFUSE REFLECTANCE INFRARED FOURIER-TRANSFORM (DRIFT) METHOD IN PALEONTOLOGICAL STUDIES OF BONES
    DAUPHIN, Y
    APPLIED SPECTROSCOPY, 1993, 47 (01) : 52 - 55
  • [30] THE DETERMINATION OF PEROXIDE VALUE BY FOURIER-TRANSFORM INFRARED-SPECTROSCOPY
    VANDEVOORT, FR
    ISMAIL, AA
    SEDMAN, J
    DUBOIS, J
    NICODEMO, T
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1994, 71 (09) : 921 - 926