Proportional Capacitor Current Feedback Based Active Damping Control for LCL-Filter Converters with Considerable Control Delay

被引:0
|
作者
ZhijunMa [1 ]
Zhou, Linyuan [1 ]
Liu, Jinjun [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian, Peoples R China
关键词
active damping; LCL; capacitor current feedback; INVERTER; DESIGN;
D O I
10.1109/apec39645.2020.9124121
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
LCL filter is widely used in grid connected converters for good harmonic mitigation performance. However, resonance poles of LCL filter challenge the system stability, especially in digital controlled system. Various active damping approaches have been proposed to solve the resonance issue, where the capacitor current based active damping control is an attractive option. In this paper, system stability with capacitor current based active damping control is analyzed with the consideration of digital control delay. A design principle for the active damping compensator is proposed in this paper, where maximum stability margin can be reached for active damping loop. It is shown that capacitor current feedback control with negative proportion gain, instead of positive gain, presents much better performance with considerable control delay. Simulative and experimental results validate the proposed control method.
引用
收藏
页码:3110 / 3114
页数:5
相关论文
共 50 条
  • [41] Grid Current Feedback Active Damping Control Based on Disturbance Observer for Battery Energy Storage Power Conversion System with LCL Filter
    Gao, Ning
    Lin, Xin
    Wu, Weimin
    Blaabjerg, Frede
    ENERGIES, 2021, 14 (05)
  • [42] Active Damping Control for LCL Filters With Inverter-Side Current Feedback Only
    Chen, Wei
    Zhang, Yan
    Tu, Yiming
    Shen, Ke
    Liu, Jinjun
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (09) : 10065 - 10069
  • [43] A stable three-phase LCL-filter based active rectifier without damping
    Teodorescu, R
    Blaabjerg, F
    Liserre, M
    Dell'Aquila, A
    2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS, 2003, : 1552 - 1557
  • [44] Design of LCL-filter considering the control impact for grid-connected inverter with one current feedback only
    Xu, Jinming
    Xie, Shaojun
    Huang, Liuliu
    Ji, Lin
    IET POWER ELECTRONICS, 2017, 10 (11) : 1324 - 1332
  • [45] Genetic algorithm based design of the active damping for a LCL-filter three-phase active rectifier
    Liserre, M
    Dell'Aquila, A
    Blaabjerg, F
    APEC 2003: EIGHTEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2003, : 234 - 240
  • [46] Capacitor Current Feedback Active Damping for Shunt Active Power Filter with Output LLCL Filter
    Buyuk, Mehmet
    Inci, Mustafa
    Tan, Adnan
    Tumay, Mehmet
    2017 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2017, : 376 - 379
  • [47] The PWM rectifier with LCL filter direct power control based on power damping feedback
    Fan, Bo
    Zhang, Qianqian
    Zhao, Zhengxin
    Gu, Shuaihui
    JOURNAL OF VIBROENGINEERING, 2021, 23 (02) : 471 - 483
  • [48] Filter Capacitor Current Estimation and Grid Current Control in LCL based Grid Connected Inverter
    Mukherjee, Subhajyoti
    Chowdhury, Vikram Roy
    Shamsi, Pourya
    Ferdowsi, Mehdi
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 3885 - 3889
  • [49] Digital Realization of Capacitor-Voltage Feedback Active Damping for LCL-Filtered Grid Converters
    Xin, Zhen
    Wang, Xiongfei
    Loh, Poh Chiang
    Blaabjerg, Frede
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 2690 - 2697
  • [50] On the Limits of the Capacitor-Voltage Active Damping for Grid-Connected Power Converters with LCL Filter
    Samanes, Javier
    Gubia, Eugenio
    2018 IEEE 19TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2018,