Pinhole SPECT reconstruction using blobs and resolution recovery

被引:24
作者
Andreyev, Andriy [1 ]
Defrise, Michel [1 ]
Vanhove, Christian [1 ]
机构
[1] Vrije Univ Brussel, Dept Nucl Med, B-1090 Brussels, Belgium
关键词
blobs; pinhole spect reconstruction; regularization; resolution recovery (RR);
D O I
10.1109/TNS.2006.878004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We study the performance of an iterative reconstruction algorithm for single pinhole SPECT, in which the correction for pinhole blurring is realized by averaging multiple projection rays by means of a Gaussian quadrature method. In addition we compare the regularizing effect obtained by using blobs basis functions and voxels with and without postsmoothing. Contrast-noise and resolution-noise studies with a mathematical phantom show that blobs improve the tradeoff between bias and variance compared to voxels with the same grid spacing. The performance of the voxel reconstruction is improved significantly by using postsmoothing with a Gaussian kernel and by taking finer voxel sampling, but the results with blobs remain better provided the parameters of the blobs are carefully selected. We have also reconstructed measured pinhole data for a resolution phantom and for the bone scan of a rat. With these data the visual difference between the postsmoothed voxel reconstruction and the blob reconstruction is small.
引用
收藏
页码:2719 / 2728
页数:10
相关论文
共 35 条
[1]  
Abramowitz M., 1970, HDB MATH FUNCTIONS
[2]   Slab-by-slab blurring model for geometric point response correction and attenuation correction using iterative reconstruction algorithms [J].
Bai, CY ;
Zeng, GL ;
Gullberg, GT ;
DiFilippo, F ;
Miller, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) :2168-2173
[3]  
BAL G, 2005, 8 INT M FULL 3 DIM I, P259
[4]   Design and simulation of a high-resolution stationary SPECT system for small animals [J].
Beekman, FJ ;
Vastenhouw, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4579-4592
[5]   Selection of task-dependent diffusion filters for the post-processing of SPECT images [J].
Beekman, FJ ;
Slijpen, ETP ;
Niessen, WJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1713-1730
[6]   Optimization of geometrical calibration in pinhole SPECT [J].
Bequé, D ;
Nuyts, J ;
Suetens, P ;
Bormans, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (02) :180-190
[7]  
BEQUE D, 2004, 2004 IEEE NUCL SCI S
[8]  
Brown J. K., 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (Cat. No.95CH35898), P1272, DOI 10.1109/NSSMIC.1995.510491
[9]  
Cherry SR, 2004, PHYS MED BIOL, V49, pR13, DOI 10.1088/0031-9155/49/3/R01
[10]  
Constantinesco A, 2005, J NUCL MED, V46, P1005