Validation of the Hingmed WBP-02A device for ambulatory blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010

被引:2
|
作者
Fania, Claudio [1 ]
Vezzu, Leonardo [1 ]
Lazzaretto, Ilaria [1 ]
Palatini, Paolo
机构
[1] Casa Cura Villa Maria Hosp, Padua, Italy
关键词
ambulatory; blood pressure; device; validation;
D O I
10.1097/MBP.0000000000000371
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The objective of this study was to determine the accuracy of the Hingmed WBP-02A device for ambulatory blood pressure (BP) monitoring according to the International Protocol of the European Society of Hypertension (ESH-IP). Device evaluation was carried out in 33 patients. The mean age was 69.8 +/- 13.8 years, the mean systolic BP was 137.6 +/- 27.0 mmHg (range: 96-172), the mean diastolic BP was 86.7 +/- 20.1 mmHg (range: 48-124) and the mean arm circumference was 30.1 +/- 6.2 cm (range: 20-43). The protocol requirements were followed precisely. Four different cuffs, small, standard, large, and extra-large were used. The device comfortably passed all ESH-IP requirements, as 84 out of 99 device-observer systolic BP differences and 97 of 99 diastolic BP differences were within +/- 5 mmHg thereby fulfilling the standards of the protocol. Device-observer BP differences were unrelated to arm circumference. These data show that the Hingmed WBP-02A device for ambulatory BP monitoring met the requirements for validation by the ESH-IP and can be recommended for clinical use in the adult population. Copyright (C) 2019 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:151 / 154
页数:4
相关论文
共 50 条
  • [1] Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010
    Bramlage, Peter
    Deutsch, Cornelia
    Krueger, Ralf
    Wolf, Andreas
    Mueller, Peter
    Zwingers, Thomas
    Beime, Beate
    Mengden, Thomas
    VASCULAR HEALTH AND RISK MANAGEMENT, 2014, 10 : 303 - 309
  • [2] Validation of the TONOPORT VI ambulatory blood pressure monitor in adults according to the European Society of Hypertension International Protocol revision 2010
    M Abou-Dakn
    C Döhmen
    S Wenzel
    Journal of Human Hypertension, 2017, 31 : 89 - 92
  • [3] Validation of the TONOPORT VI ambulatory blood pressure monitor in adults according to the European Society of Hypertension International Protocol revision 2010
    Abou-Dakn, M.
    Doehmen, C.
    Wenzel, S.
    JOURNAL OF HUMAN HYPERTENSION, 2017, 31 (02) : 89 - 92
  • [4] Validation of the blood pressure measurement device Erkameter 125 PRO according to the European Society of Hypertension International Protocol revision 2010
    Beime, Beate
    Deutsch, Cornelia
    Krueger, Ralf
    Zimmermann, Erik
    Bramlage, Peter
    BLOOD PRESSURE MONITORING, 2016, 21 (06) : 356 - 360
  • [5] Validation of the blood pressure measurement device Beurer BM 28 according to the European Society of Hypertension International Protocol revision 2010
    Deutsch, Cornelia
    Bramlage, Carsten
    Botta, Beate
    Krueger, Ralf
    Forstner, Klaus
    Bramlage, Peter
    Beime, Beate
    BLOOD PRESSURE MONITORING, 2021, 26 (04) : 292 - 298
  • [6] Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Beime, Beate
    Deutsch, Cornelia
    Krueger, Ralf
    Wolf, Andreas
    Mueller, Peter
    Hammel, Gertrud
    Bramlage, Peter
    EUROPEAN JOURNAL OF PEDIATRICS, 2017, 176 (05) : 573 - 580
  • [7] Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Beate Beime
    Cornelia Deutsch
    Ralf Krüger
    Andreas Wolf
    Peter Müller
    Gertrud Hammel
    Peter Bramlage
    European Journal of Pediatrics, 2017, 176 : 573 - 580
  • [8] Validation of the PHYSIO-PORT UP ambulatory blood pressure monitor in pregnant women according to the European Society of Hypertension International Protocol revision 2010
    Michael Abou-Dakn
    Sabine Wenzel
    Journal of Human Hypertension, 2018, 32 : 770 - 774
  • [9] Validation of the PHYSIO-PORT UP ambulatory blood pressure monitor in pregnant women according to the European Society of Hypertension International Protocol revision 2010
    Abou-Dakn, Michael
    Wenzel, Sabine
    JOURNAL OF HUMAN HYPERTENSION, 2018, 32 (11) : 770 - 774
  • [10] Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Kang, Yuan-Yuan
    Chen, Qi
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2016, 21 (04) : 255 - 258