Validation and feasibility of liver T1 mapping using free breathing MOLLI sequence in children and young adults

被引:9
作者
Cho, Yeon Jin [1 ]
Kim, Woo Sun [1 ,2 ,3 ]
Choi, Young Hun [1 ]
Lee, Seul Bi [1 ]
Lee, SeungHyun [1 ]
Cheon, Jung-Eun [1 ,2 ,3 ]
Paek, MunYoung [4 ]
Woo, SeungTae [5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dept Radiol, Coll Med, 103 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, 103 Daehak Ro, Seoul 03080, South Korea
[4] Siemens Healthcare Ltd, 23 Chungjeong Ro, Seoul 03737, South Korea
[5] Radiol Bayer Korea Ltd, 23 Boramae Ro, Seoul 07071, South Korea
关键词
INVERSION-RECOVERY MOLLI; HEPATIC-FIBROSIS; RELAXATION-TIME; MR RELAXOMETRY; CIRRHOSIS;
D O I
10.1038/s41598-020-74717-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We investigated the feasibility of free-breathing modified Look-Locker inversion recovery (MOLLI) sequence for measuring hepatic T1 values in children and young adults. To investigate the accuracy and the reproducibility of the T1 maps, a phantom study was performed with 12 different gadoterate meglumine concentrations and the T1 relaxation times of phantoms measured with the MOLLI sequence were compared against those measured with three different sequences: spin-echo inversion recovery, variable flip angle (VFA), and VFA with B1 correction. To evaluate the feasibility of freebreathing MOLLI sequence, hepatic T1 relaxation times obtained by free-breathing and breath-hold technique in twenty patients were compared. The phantom study revealed the excellent accuracy and reproducibility of MOLLI. In twenty patients, the mean value of hepatic T1 values obtained by free-breathing (606.7 +/- 64.5 ms) and breath-hold (609.8 +/- 64.0 ms) techniques showed no significant difference (p > 0.05). The Bland-Altman plot between the free-breathing and breath-hold revealed that the mean difference of T1 values was - 3.0 ms (- 0.5%). Therefore, T1 relaxation times obtained by MOLLI were comparable to the values obtained using the standard inversion recovery method. The hepatic T1 relaxation times measured by MOLLI technique with free-breathing were comparable to those obtained with breath-hold in children and young adults.
引用
收藏
页数:9
相关论文
共 23 条
  • [11] A Comprehensive Review of Noninvasive Liver Fibrosis Tests in Pediatric Nonalcoholic Fatty Liver Disease
    Mansoor S.
    Collyer E.
    Alkhouri N.
    [J]. Current Gastroenterology Reports, 2015, 17 (6)
  • [12] Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart
    Messroghli, DR
    Radjenovic, A
    Kozerke, S
    Higgins, DM
    Sivananthan, MU
    Ridgway, JP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 141 - 146
  • [13] Influence of Fat on Liver T1 Measurements Using Modified Look-Locker Inversion Recovery (MOLLI) Methods at 3T
    Mozes, Ferenc E.
    Tunnicliffe, Elizabeth M.
    Pavlides, Michael
    Robson, Matthew D.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 105 - 111
  • [14] Native myocardial longitudinal (T1) relaxation time: Regional, age, and sex associations in the healthy adult heart
    Rauhalammi, Samuli M. O.
    Mangion, Kenneth
    Barrientos, Pauline Hall
    Carrick, David J. A.
    Clerfond, Guillaume
    McClure, John
    McComb, Christie
    Radjenovic, Aleksandra
    Berry, Colin
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (03) : 541 - 548
  • [15] Regev A, 2002, AM J GASTROENTEROL, V97, P2614, DOI 10.1111/j.1572-0241.2002.06038.x
  • [16] Assessment of liver fibrosis using T1 mapping on Gd-EOB-DTPA-enhanced magnetic resonance
    Sheng, Ruo Fan
    Wang, He Qing
    Yang, Li
    Jin, Kai Pu
    Xie, Yan Hong
    Fu, Cai Xia
    Zeng, Meng Su
    [J]. DIGESTIVE AND LIVER DISEASE, 2017, 49 (07) : 789 - 795
  • [17] On the Accuracy of T1 Mapping: Searching for Common Ground
    Stikov, Nikola
    Boudreau, Mathieu
    Levesque, Ives R.
    Tardif, Christine L.
    Barral, Joelle K.
    Pike, G. Bruce
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 514 - 522
  • [18] T1 Mapping Basic Techniques and Clinical Applications
    Taylor, Andrew J.
    Salerno, Michael
    Dharmakumar, Rohan
    Jerosch-Herold, Michael
    [J]. JACC-CARDIOVASCULAR IMAGING, 2016, 9 (01) : 67 - 81
  • [19] Evaluation of variable flip angle, MOLLI, SASHA, and IR-SNAPSHOT pulse sequences for T1 relaxometry and extracellular volume imaging of the pancreas and liver
    Tirkes, Temel
    Zhao, Xuandong
    Lin, Chen
    Stuckey, Alex Jordan
    Li, Liang
    Giri, Shivriman
    Nickel, Dominik
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (05) : 559 - 566
  • [20] Free-breathing MOLLI: Application to myocardial T1 mapping
    Tsai, Jyun-Ming
    Huang, Teng-Yi
    Tseng, Yu-Shen
    Lin, Yi-Ru