Validation and feasibility of liver T1 mapping using free breathing MOLLI sequence in children and young adults

被引:9
作者
Cho, Yeon Jin [1 ]
Kim, Woo Sun [1 ,2 ,3 ]
Choi, Young Hun [1 ]
Lee, Seul Bi [1 ]
Lee, SeungHyun [1 ]
Cheon, Jung-Eun [1 ,2 ,3 ]
Paek, MunYoung [4 ]
Woo, SeungTae [5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dept Radiol, Coll Med, 103 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, 103 Daehak Ro, Seoul 03080, South Korea
[4] Siemens Healthcare Ltd, 23 Chungjeong Ro, Seoul 03737, South Korea
[5] Radiol Bayer Korea Ltd, 23 Boramae Ro, Seoul 07071, South Korea
关键词
INVERSION-RECOVERY MOLLI; HEPATIC-FIBROSIS; RELAXATION-TIME; MR RELAXOMETRY; CIRRHOSIS;
D O I
10.1038/s41598-020-74717-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We investigated the feasibility of free-breathing modified Look-Locker inversion recovery (MOLLI) sequence for measuring hepatic T1 values in children and young adults. To investigate the accuracy and the reproducibility of the T1 maps, a phantom study was performed with 12 different gadoterate meglumine concentrations and the T1 relaxation times of phantoms measured with the MOLLI sequence were compared against those measured with three different sequences: spin-echo inversion recovery, variable flip angle (VFA), and VFA with B1 correction. To evaluate the feasibility of freebreathing MOLLI sequence, hepatic T1 relaxation times obtained by free-breathing and breath-hold technique in twenty patients were compared. The phantom study revealed the excellent accuracy and reproducibility of MOLLI. In twenty patients, the mean value of hepatic T1 values obtained by free-breathing (606.7 +/- 64.5 ms) and breath-hold (609.8 +/- 64.0 ms) techniques showed no significant difference (p > 0.05). The Bland-Altman plot between the free-breathing and breath-hold revealed that the mean difference of T1 values was - 3.0 ms (- 0.5%). Therefore, T1 relaxation times obtained by MOLLI were comparable to the values obtained using the standard inversion recovery method. The hepatic T1 relaxation times measured by MOLLI technique with free-breathing were comparable to those obtained with breath-hold in children and young adults.
引用
收藏
页数:9
相关论文
共 23 条
  • [1] 3D T1 relaxometry pre and post gadoxetic acid injection for the assessment of liver cirrhosis and liver function
    Besa, Cecilia
    Bane, Octavia
    Jajamovich, Guido
    Marchione, Joseph
    Taouli, Bachir
    [J]. MAGNETIC RESONANCE IMAGING, 2015, 33 (09) : 1075 - 1082
  • [2] Pediatric MR elastography of hepatic fibrosis: principles, technique and early clinical experience
    Binkovitz, Larry A.
    El-Youssef, Mounif
    Glaser, Kevin J.
    Yin, Meng
    Binkovitz, Anna K.
    Ehman, Richard L.
    [J]. PEDIATRIC RADIOLOGY, 2012, 42 (04) : 402 - 409
  • [3] MR relaxometry in chronic liver diseases: Comparison of T1 mapping, T2 mapping, and diffusion-weighted imaging for assessing cirrhosis diagnosis and severity
    Cassinotto, Christophe
    Feldis, Matthieu
    Vergniol, Julien
    Mouries, Amaury
    Cochet, Hubert
    Lapuyade, Bruno
    Hocquelet, Arnaud
    Juanola, Etienne
    Foucher, Juliette
    Laurent, Francois
    De Ledinghen, Victor
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) : 1459 - 1465
  • [4] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    [J]. RADIOLOGY, 2004, 230 (03) : 652 - 659
  • [5] Pediatric liver diseases: current challenges and future perspectives
    Della Corte, Claudia
    Mosca, Antonella
    Vania, Andrea
    Alterio, Arianna
    Alisi, Anna
    Nobili, Valerio
    [J]. EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY, 2016, 10 (02) : 255 - 265
  • [6] Quality and safety in pediatric radiology
    Dillman, Jonathan R.
    Larson, David B.
    [J]. PEDIATRIC RADIOLOGY, 2019, 49 (04) : 431 - 432
  • [7] Magnetic resonance imaging T1 relaxation times for the liver, pancreas and spleen in healthy children at 1.5 and 3tesla
    Gilligan, Leah A.
    Dillman, Jonathan R.
    Tkach, Jean A.
    Xanthakos, Stavra A.
    Gill, Jacqueline K.
    Trout, Andrew T.
    [J]. PEDIATRIC RADIOLOGY, 2019, 49 (08) : 1018 - 1024
  • [8] Gd-EOB-DTPA-enhanced MR relaxometry for the detection and staging of liver fibrosis
    Haimerl, Michael
    Utpatel, Kirsten
    Verloh, Niklas
    Zeman, Florian
    Fellner, Claudia
    Nickel, Dominik
    Teufel, Andreas
    Fichtner-Feigl, Stefan
    Evert, Matthias
    Stroszczynski, Christian
    Wiggermann, Philipp
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [9] MR relaxometry of the liver: significant elevation of T1 relaxation time in patients with liver cirrhosis
    Heye, Tobias
    Yang, Schu-Ren
    Bock, Michael
    Brost, Sylvia
    Weigand, Kilian
    Longerich, Thomas
    Kauczor, Hans-Ulrich
    Hosch, Waldemar
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (06) : 1224 - 1232
  • [10] T1 mapping for liver function evaluation in gadoxetic acid-enhanced MR imaging: comparison of look-locker inversion recovery and B1 inhomogeneity-corrected variable flip angle method
    Kim, Ji Eun
    Kim, Hyun Ok
    Bae, Kyungsoo
    Choi, Dae Seob
    Nickel, Dominik
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (07) : 3584 - 3594